The Transactions of the Korean Institute of Power Electronics / v.23, no.6, 2018 , pp. 440-445 More about this Journal
Abstract
This study proposes a novel control and design method for a grid-connected inverter with an LCL filter without damping. The current resonance phenomenon must be considered when designing the grid-connected inverter system with an LCL filter. Passive or active damping is used in the inverter system to reduce the resonant current. However, passive damping reduces the efficiency of the system, and active damping methods are complex. If the resonant frequency is in a specific region, then the system will be unstable. This study examines the process of stabilizing the entire region without resonant damping. The validity of the proposed method is verified through simulation and experimentation.
Keywords
Grid-connected inverter; LCL filter; Active damping; Passive damping;
Citations & Related Records
연도 인용수 순위
  • Reference
1 R. P. Alzola, M. Liserre, F. Blaabjerg, R. Sebastian, J. Dannehl, and F. W. Fuchs, "Analysis of the passive damping losses in LCL-filter-based grid converters," IEEE Trans. Power Electron, Vol. 28, No. 6, pp. 2642-2646, Jun. 2013.   DOI
2 R. Pena-Alzola, M. Liserre, F. Blaabjerg, M. Ordonez, and T. Kerekes, "A self-commissioning notch filter for active damping in a three-phase LCL filter-based grid-tie converter," IEEE Trans. Power Electron, Vol. 29, No. 12, pp. 6754-6761, Dec. 2014.   DOI
3 X. Wang, F. Blaabjerg, and P. C. Loh, "Virtual RC damping of LCL filtered voltage source converters with extended selective harmonic compensation," IEEE Trans. on Power Electron, Vol. 30, No. 9, pp. 4726-4737, Sep. 2014.   DOI
4 J. Xu, S. Xie, and T. Tang, "Active damping-based control for grid connected LCL-filtered inverter with injected grid current only," IEEE Trans. Ind. Electron, Vol. 61, No. 9, pp. 4746-4758, Sep. 2014.   DOI
5 S. Parker, B. McGrath, and D. G. Holmes, "Regions of active damping control for LCL filters," IEEE Trans. Ind. App, Vol. 50, No. 1, pp. 424-432, Jun. 2014.   DOI
6 M. Liserre, F. Blaabjerg, and A. DellAquila, "Step-by-step design procedure for a grid-connected three-phase PWM voltage source converter," Int. J. Electron, Vol. 91, No. 8, pp. 445-460, Aug. 2004.   DOI
7 D. N. Zmood and D. G. Holmes, "Stationary frame current regulation of PWM inverters with zero steady-state error," IEEE Trans. Power Electron, Vol. 18, No. 3, pp. 814-822, May. 2003.   DOI
8 P. Mattavelli, F. Polo, F. Dal Lago, and S. Saggini, "Analysis of controldelay reduction for the improvement of UPS voltage-loop bandwidth," IEEE Trans. Ind. Electron, Vol. 55, No. 8, pp. 2903-2911, Feb. 2008.   DOI