A Novel Active Damping Control of a Three-phase PWM Inverter with LC Filter  

Kim, Kwang-Seob (Dept. of Electrical Engineering, Hanyang University)
Hyun, Dong-Seok (Dept. of Electrical Engineering, Hanyang University)
Publication Information
Journal of Electrical Engineering and Technology / v.10, no.4, 2015 , pp. 1589-1596 More about this Journal
Abstract
A novel control method of a three-phase PWM inverter with LC filter is proposed. The transfer function of LC filter is the same as that of 2nd order low pass filter(2nd LPF) which has a zero damping ratio. A simple method of implementing 2nd LPF with damping ratio is to add resistor to inductor or capacitor of LC filter. In an industrial application, it is not practical to adopt damping resistor because it results in losses being proportional to square of current flowing through resistor. Instead of using damping resistors, the proposed active damping control(ADC) utilizes all pass filter(APF) and considers inherent processing delay of digital controller. The overall transfer function of the proposed method is the same as a 2nd LPF and its damping ratio is also controllable via control variables. Detailed design and implementation of controller is also presented. Experiments are conducted with a 7.5kVA induction motor drive system controlled by PWM converter and inverter. Test waveforms are also presented to verify the proposed LC filter control algorithm.
Keywords
Three-phase PWM inverter; Field oriented control; LC filter; Active damping control; All pass filter;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Ouk-Sang Park, Je-Wook Park, Chae-Bong Bae, and Jang-Mok Kim “Compensation Strategy to Eliminate the Effect of Current Measurement Offsets in Grid- Connected Inverters”, Journal of Power Electronics, Vol. 14, No. 2, pp. 383-391, March 2014.   DOI   ScienceOn
2 Osman Kukrer, “Deadbeat Control of a Three-Phase Inverter with an Output LC Filter”, IEEE Transactions on Power Electronics, Vol. 11, No. 1, pp. 16~23, January 1996.   DOI   ScienceOn
3 Jinhwan Jung, and Kwanghee Nam, “A Dynamic Decoupling Control Scheme for High-Speed Operation of Induction Motors”, IEEE Transactions on Industrial Electronics, Vol. 46, No. 1, pp. 100~110, February 1999.   DOI   ScienceOn
4 M. Liserre, F. Blaabjerg, and A. Dell’Aquila, “Step- by-step design procedure for a grid-connected three- phase PWM Voltage Source Converter,” Int. J. Electron., vol. 91, no. 8, pp. 445-460, Aug. 2004.   DOI   ScienceOn
5 Marco Liserre, Frede Blaabjerg, and Steffan Hansen, “Design and Control of an LCL-Filter-Based Three- Phase Active Rectifier”, IEEE Transactions on Industry Applications, Vol. 41, No. 5, pp. 1281~1291, September/October 2005.   DOI   ScienceOn
6 Constantine Mastorocostas, Iordanis Kioskeridis, and Nikos Margaris, “Thermal and Slip Effects on Rotor Time Constant in Vector Controlled Induction Motor Drives,” IEEE Transactions on Power Electronics, Vol. 21, No. 2, pp. 495~504, March 2006.   DOI   ScienceOn
7 J. W. Choi and S. K. Sul, “A new compensation strategy reducing voltage/current distortion in PWM VSI systems operating with low output voltages,” IEEE Transactions on Industry Applications, vol. 31, pp. 1001~1008, Sept./Oct. 1995.   DOI   ScienceOn
8 Jong-Woo Choi, and Seung-Ki Sul, “Inverter Output Voltage Synthesis Using Novel Dead Time Compensation”, IEEE Transactions on Power Electronics, Vol. 11, No. 2, pp. 221~227, March 1996.   DOI   ScienceOn
9 Jul-Ki Seok, Seung-I11 Moon, and Seung-Ki Sul, “Induction Machine Parameter Identification using PWM Inverter at Standstill”, IEEE Transactions on Energy Conversion, Vol. 12, No. 2, pp. 127~132, June 1997.   DOI   ScienceOn
10 Hae-Gwang Jeong, Dong-Keun Yoon, and Kyo-Beum Leei, “Design of an LCL-Filter for Three-Parallel Operation of Power Converters in Wind Turbines”, Journal of Power Electronics, Vol. 13, No. 3, May 2013.
11 Ali Bechouche, Djaffar Ould Abdeslam, Tahar Otmane-Cherif, and Hamid Seddiki, “Adaptive Neural PLL for Grid-connected DFIG Synchronization”, Journal of Power Electronics, Vol. 14, No. 3, pp. 608- 620, May 2014.   DOI   ScienceOn
12 Satoshi Ogasawara, and Hirofumi Akagi, “Modeling and Damping of High-Frequency Leakage Currents in PWM Inverter-Fed AC Motor Drive Systems”, IEEE Transactions on Industry Applications, Vol. 32, No. 5, pp. 1105~1114, September/October 1996.   DOI   ScienceOn
13 Annette von Jouanne, Dudi A. Rendusara, Prasad N. Enjeti, and James Will Gray, “Filtering Techniques to Minimize the Effect of Long Motor Leads on PWM Inverter-Fed AC Motor Drive Systems”, IEEE Transactions on Industry Applications, Vol. 32, No. 4, pp. 919~925, July/August 1996.   DOI   ScienceOn
14 Raymundo E. Torres-Olguin, Marta Molinas, and Tore Undeland, “Offshore Wind Farm Grid Integration by VSC Technology with LCC-Based HVDC Trans- mission”, IEEE Transactions on Sustainalbe Energy, Vol. 3, No. 4, pp. 899~907, October 2012.   DOI   ScienceOn
15 Jay M. Erdman, Russel J. Kerkman, David W. Schlegel, and Gary L. Skibinski, “Effect of PWM Inverters on AC Motor Bearing Currents and Shaft voltages”, IEEE Transactions on Industry Appli- cations, Vol. 32, No. 2, pp. 250~259, March/April 1996.   DOI   ScienceOn
16 Mari Kojima, Kazufumi Hirabayashi, Yoshitaka Kawabata, Emenike C. Ejiogu, and Takao Kawabata, “Novel Vector Control System Using Deadbeat- Controlled PWM Inverter With Output LC Filter”, IEEE Transactions on Industry Applications, Vol. 40, No. 1, pp. 162 ~169, January/February 2004.   DOI   ScienceOn
17 Juergen K. Steinke, “Use of an LC Filter to Achieve a Motor-friendly Performance of the PWM Voltage Source Inverter”, IEEE Transactions on Energy Conversion, Vol. 14, No. 3, pp. 649~655, September 1999.   DOI   ScienceOn
18 Risheng Li, Serhiy Bozhko, and Greg Asher, “Fre- quency Control Design for Offshore Wind Farm Grid With LCC-HVDS Link Connection”, IEEE Transactions on Power Delivery, Vol. 23, No. 3, pp. 1085~1092, May 2008.   DOI   ScienceOn
19 Dawei Xiang, Li Ran, Jim R. Bumby, Peter J. Tavner, and Shunchang Yang, “Coordinated Control of an HVDC Link and doubly fed induction generator in a large offshore wind farm”, IEEE Transactions on Power Delivery, Vol. 21, No. 21, pp. 463~471, January 2006.   DOI   ScienceOn