• 제목/요약/키워드: Inverter Drives

검색결과 302건 처리시간 0.023초

단상 풀 브리지 인버터를 이용한 SRM 컨버터 토폴로지 (The Converter Topology with full Bridge Inverter for the Switched Reluctance Motor Drives)

  • 장도현
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권8호
    • /
    • pp.475-481
    • /
    • 2002
  • In this paper the new converter topology using single-Phase full bridge inverter for the switched reluctance motor drives is proposed. The proposed SRM drives are supplied by the AC pulse voltage source, while the conventional drives are supplied by the DC voltage source. Speed of the SRM is controlled by adjusting the frequency and the multitude of output current of inverter. The SRM using the proposed converter reduces the switching loss and the machine core loss, and has ability to pre-regulate the input voltage. The total number of power switches become fewer than another topology as a number of stator poles becomes more. Power circuit of an inverter is simpler and its volume is smaller because the module device involving several switches is used as an inverter.

전류형 GTO Inverter와 그 기본특성 (New Current-fed GTO Inverter and Its Basic Characteristics)

  • 임달호;;이종하
    • 대한전기학회논문지
    • /
    • 제36권1호
    • /
    • pp.3-8
    • /
    • 1987
  • The conventional autosequentially commutated current-fed inverter (ASCI) is widely employed with the induction motor drives for speed control. Howener, this inverter has a limit of high power and high frequency indution motor drives. One of the limitations is to be found in the commutation capacitors in the main circuit of this inverter. A new current-fed gate turn-off thyristor (GTO) inverter is developed. This inverter is composed of the main GTO bridge configuration and the improved energy rebound circuit (ERC)without the commutation capacitor. This inverter works stable at high frequency from light load to heavy one. The improved ERC is used not only to rebound the load reactive power to the dc link, but also to return the power in the load to the ac source. The new GTO inverter circuit and the characteristics of the inverter induction motor drives are explained and analyzed.

  • PDF

Analysis of Multi Level Current Source GTO Inverter for Induction Motor Drives

  • Arase, Takayuki;Matususe, Kouki
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.535-540
    • /
    • 1998
  • This paper discusses a triple stage current source GTO inverter system for high power motor drives. The energy rebound circuit of the triple stage inverter not only controls the spike voltage of the GTO inverter but also facilitates PWM control of the thyristor rectifier operated at unity fundamental input power factor. Based on Pspice simulation and experiments, the principles and PWM pulse pattern for removing specific lower harmonics in the inverter's output current are discussed in detail.

  • PDF

단상 풀 브리지 인버터를 이용한 SRM 컨버터 토폴로지 (The Converter with Full Bridge Inverter for the Switched Reluctance Motor Drives)

  • 장도현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.989-991
    • /
    • 2001
  • The new converter topology using full bridge inverter for the switched reluctance motor drives is proposed. The proposed SRM drives are supplied by the pulse voltage source, while the conventional drives are supplied by dc voltage source. Proposed converter maintains the characteristics of asymmetric bridge converter and has advanced characteristics.

  • PDF

단상 하프 브리지 인버터를 이용한 스위치드 리럭턴스 전동기용 컨버터 토폴로지 (The Converter with Half Bridge Inverter for the Switched Reluctance Motor Drives)

  • 장도현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.335-337
    • /
    • 2001
  • The new converter topology using half bridge inverter for the switched reluctance motor drives is proposed. The proposed SRM drives are supplied by the pulse voltage source, while the conventional drives are supplied by de voltage source. Proposed converter does not lose the characteristics of classic converter though the total no. of power switches are reduced.

  • PDF

SVPWM Overmodulation Scheme of Three-Level Inverters for Vector Controlled Induction Motor Drives

  • Kwon, Kyoung-Min;Lee, Jae-Moon;Lee, Jin-Mok;Choi, Jae-Ho
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.481-490
    • /
    • 2009
  • This paper describes a SVPWM overmodulation scheme of NPC type three-level inverter for traction drives which extends the modulation index from MI=0.907 to unity. SVPWM strategy is organized by two operation modes of under-modulation and over-modulation. The switching states under the under-modulation modes are determined by dividing them with two linear regions and one hybrid region the same as the conventional three-level inverter. On the other hand, under the over-modulation mode, they are generated by doing it with two over-modulation regions the same as the conventional over-modulation strategy of a two level inverter. Following the description of over-modulation scheme of a three-level inverter, the system description of a vector controlled induction motor for traction drives has been discussed. Finally, the validity of the proposed modulation algorithm has been verified through simulation and experimental results.

Rotor Fault Detection System for Inverter Driven Induction Motors using Currents Signals and an Encoder

  • Kim, Nam-Hun
    • Journal of Power Electronics
    • /
    • 제7권4호
    • /
    • pp.271-277
    • /
    • 2007
  • In this paper, an induction motor rotor fault diagnosis system using current signals, which are measured using the axis-transformation method is presented. Inverter-fed motor drives, unlike line-driven motor drives, have stator currents which are rich in harmonics and therefore fault diagnosis using stator current is not trivial. The current signals for rotor fault diagnosis need precise and high resolution information, which means the diagnosis system demands additional hardware such as a low pass filter, high resolution ADC, an encoder and additional hardware. Therefore, the proposed axis-transformation method is expected to contribute to a low cost fault diagnosis system in inverter-fed motor drives without the need for any additional hardware. In order to confirm the validity of the developed algorithms, various experiments for rotor faults are tested and the line current spectrum of each faulty situation, using the Park transformation, is compared with the results obtained from the FFT(Fast Fourier Transform).

Low Cost Rotor Fault Detection System for Inverter Driven Induction Motor

  • Kim, Nam-Hun;Choi, Chang-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권4호
    • /
    • pp.500-504
    • /
    • 2007
  • In this paper, the induction motor rotor fault diagnosis system using current signals, which are measured using axis-transformation method, and speed, which is estimated using current information, are presented. In inverter-fed motor drives unlike line-driven motor drives the stator currents have numerous harmonics components and therefore fault diagnosis using stator currents is very difficult. The current and speed signal for rotor fault diagnosis needs to be precise. Also, high resolution information, which means the diagnosis system, demands additional hardware such as low pass filter, high resolution ADC, encoder and etc. Therefore, the proposed axis-transformation and speed estimation method are expected to contribute to low cost fault diagnosis systems in inverter-fed motor drives without the need for an encoder and any additional hardware. In order to confirm validity of the developed algorithms, various experiments for rotor faults are tested and the line current spectrum of each faulty situation using Park transformation and speed estimation method are compared with the results obtained from fast Fourier transforms.

3-레벨 ANPC 인버터의 고장 허용 운전 시 중성점 전압 균형 제어 기법 (Neutral-Point Voltage Balancing Control Scheme for Fault-Tolerant Operation of 3-Level ANPC Inverter)

  • 이재운;김지원;박병건;노의철
    • 전력전자학회논문지
    • /
    • 제24권2호
    • /
    • pp.120-126
    • /
    • 2019
  • This study proposes a neutral voltage balance control scheme for stable fault-tolerant operation of an active neutral point clamped (ANPC) inverter using carrier-based pulse width modulation. The proposed scheme maintains the neutral voltage balance by reconfiguring the switching combination and modulating the reference output voltage in order to solve the degradation of the output characteristic in the fault tolerant operation due to the fault of the power semiconductor switch constituting the ANPC inverter. The feasibility of the proposed control scheme is confirmed by HIL experiment using RT-BOX.

3상 유도전동기 구동용 새로운 ZVT 인버터의 제어기법 (A Control Strategy of the ZVT Inverter for Induction Motor Drives)

  • 송인석;이성룡
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.10-13
    • /
    • 1998
  • In this paper, a control strategy of the three phase ZVT inverter for ac motor drives is proposed. The topology of ZVT inverter analyzed with a description of the control conditions dependent on the load current and MSVM(Modified Space Vector Modulation). The detailed simulation results indicate that zero-voltage operation during transition of the MSVM algorithm can be achieved.

  • PDF