• 제목/요약/키워드: Intracranial aneurysm, wide necked

검색결과 14건 처리시간 0.023초

Selective Temporary Stent-Assisted Coil Embolization for Intracranial Wide-Necked Small Aneurysms Using Solitaire AB Retrievable Stent

  • Heo, Han Yong;Ahn, Jae Guen;Ji, Cheol;Yoon, Won Ki
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권1호
    • /
    • pp.27-34
    • /
    • 2019
  • Objective : Stent-assisted coil embolization of intracranial wide-necked aneurysm requires long-term postoperative antiplatelet therapy to prevent in-stent thrombosis. This study aimed to demonstrate results of temporary stent placement for coiling wide necked small intracranial aneurysms, which eliminated need for antiplatelet agents, and to discuss its feasibility and safety. Methods : Data of 156 patients who underwent stent-assisted coil embolization between 2011 and 2014 were retrospectively analyzed. Thirteen cases of temporary stent-assisted coil embolization were included, and their clinical and radiological results were evaluated. Results : The aneurysms treated were all unruptured except one case. All of them had wide neck with mean dome-to-neck ratio of 0.96 and were small-sized aneurysms with mean maximal diameter of 4.2 mm. There was no technical failure in retrieval of stent after completion of embolization of the target aneurysm. Immediate angiography revealed 11 complete and two partial embolization (one residual neck and one residual aneurysm). Two cases encountered thrombosis complication, and they were managed without neurological sequelae. The mean follow-up period was 43 months, angiographic follow-up revealed two cases with minor recurrence, and clinical outcome was good with modified Rankin scale score of 0. Conclusion : Temporary stent-assisted coil embolization of small wide-necked intracranial aneurysm using fully retrievable stent appears safe and effective. Further application and evaluation of this technique in more cases with larger size aneurysm is warranted.

Y-Stenting Endovascular Treatment for Ruptured Intracranial Aneurysms : A Single-Institution Experience in Korea

  • Lee, Woo Joo;Cho, Chun-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권3호
    • /
    • pp.187-192
    • /
    • 2012
  • Objective : Stent-assisted coiling on intracranial aneurysm has been considered as an effective technique and has made the complex aneurysms amenable to coiling. To achieve reconstruction of intracranial vessels with preservation of parent artery the use of stents has the greatest potential for assisted coiling. We report the results of our experiences in ruptured wide-necked intracranial aneurysms using Y-stent coiling. Methods : From October 2003 to October 2011, 12 patients (3 men, 9 women; mean age, 62.6) harboring 12 complex ruptured aneurysms (3 middle cerebral artery, 9 basilar tip) were treated by Y-stent coiling by using self-expandable intracranial stents. Procedural complications, clinical outcome, and initial and midterm angiographic results were evaluated. The definition of broad-necked aneurysm is neck diameter over than 4 mm or an aneurysm with a neck diameter smaller than 4 mm in which the dome/neck ratio was less than 2. Results : In all patients, the aneurysm was successfully occluded with no apparent procedure-related complication. There was no evidence of thromboembolic complication, arterial dissection and spasm during procedure. Follow-up studies showed stable and complete occlusion of the aneurysm in all patients with no neurologic deficits. Conclusion : The present study did show that the Y-stent coiling seemed to facilitate endovascular treatment of ruptured wide-necked intracranial aneurysms. More clinical data with longer follow-up are needed to establish the role of Y-stent coiling in ruptured aneurysms.

Endovascular Treatment of Wide-Necked Intracranial Aneurysms : Techniques and Outcomes in 15 Patients

  • Kim, Jin-Wook;Park, Yong-Seok
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권2호
    • /
    • pp.97-101
    • /
    • 2011
  • Objective : It is technically difficult to treat wide-necked intracranial aneurysms by the endovascular method. Various tools and techniques have been introduced to overcome the related technical limitations. The purpose of this study was to evaluate the radiologic and clinical results of widenecked intracranial aneurysm treatment using the endovascular method. Methods : Fifteen aneurysms in 15 patients were treated by the endovascular method from October 2009 to August 2010. Seven patients presented with subarachnoid hemorrhage (SAH), seven patients had unruptured aneurysms, and one patient had an intracerebral hemorrhage and intraventricular hemorrhage due to an incompletely clipped aneurysm. The mean dome-to-neck ratio was 1.1 (range, 0.6-1.7) and the mean height-to-neck ratio was 1.1 (range, 0.6-2.0). We used double microcatheters instead of a stent or a balloon for the first trial. When we failed to make a stable coil frame with two coils, we used a stent-assisted technique. Results : All aneurysms were successfully embolized. Eleven aneurysms (73%) were embolized by the double microcatheter technique without stent insertion, and four aneurysms (27%) were treated by stent-assisted coil embolization. One case had subclinical procedure-related intraoperative hemorrhage. Another case had procedure-related thromboembolism in the left distal anterior cerebral artery. During the follow-up period, one patient (7%) had a recanalized aneurysmal neck 12 months after coil embolization. The recurrent aneurysm was treated by stent-assisted coil embolization. Conclusion : We successfully treated 15 wide-necked intracranial aneurysms by the endovascular method. More clinical data with longer follow-up periods are needed to establish the use of endovascular treatment for wide-necked aneurysm.

Semi-Jailing Technique Using a Neuroform3 Stent for Coiling of Wide-Necked Intracranial Aneurysms

  • Ko, Jun Kyeung;Cho, Won Ho;Cha, Seung Heon;Choi, Chang Hwa;Lee, Sang Weon;Lee, Tae Hong
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권2호
    • /
    • pp.146-154
    • /
    • 2017
  • Objective : The semi-jailing technique (SJT) provides stent-assisted remodeling of the aneurysm neck during coil embolization without grasping the coil delivery microcatheter. We retrospectively evaluated the efficacy and safety of SJT using a Neuroform3 stent for coiling of wide-necked intracranial aneurysms. Methods : We collected the clinical and radiological data between January 2009 and June 2015 of the wide-necked aneurysms treated with SJT using a Neuroform3 stent. Results : SJT using a Neuroform3 stent was attempted in 70 wide-necked aneurysms (68 patients). There were 56 unruptured and 14 ruptured aneurysms. The size of aneurysm ranged from 1.7 to 28.1 mm (mean 6.1 mm). The immediate angiographic results were complete occlusion in 55 aneurysms (78.6%), neck remnant in 7 (10.0%), and aneurysm remnant in 8 (11.4%). Overall, periprocedural complications occurred in 13 patients (19.1%), including asymptomatic thromboembolism in 7 (10.3%), symptomatic thromboembolism in 4 (5.9%), and symptomatic hemorrhagic complications in 2 (2.9%). Conventional angiography follow-up was obtained in 55 (78.6%) of 70 aneurysms (mean, 10.9 months). The result showed progressive occlusion in 7 aneurysms (12.7%) and recanalization in 1 aneurysm (1.8%). At the end of the observation period (mean, 17.5 months), all 54 patients without subarachnoid hemorrhage showed excellent clinical outcomes (modified Rankin Scale [mRS] 0), except two (mRS 1 or 2) and seven of 14 patients with subarachnoid hemorrhage remained symptom-free (mRS 0). Conclusion : In this report of 70 aneurysms, SJT using a Neuroform3 stent for coiling of wide-necked intracranial aneurysms showed good technical safety, as well as favorable clinical and angiographic outcomes.

Angiographic Results of Wide-Necked Intracranial Aneurysms Treated with Coil Embolization : A Single Center Experience

  • Song, Joon Ho;Chang, In Bok;Ahn, Jun Hyong;Kim, Ji Hee;Oh, Jae Keun;Cho, Byung Moon
    • Journal of Korean Neurosurgical Society
    • /
    • 제57권4호
    • /
    • pp.250-257
    • /
    • 2015
  • Objective : Endovascular treatment of wide-necked intracranial aneurysms is a challenge and the durability and the safety of these treated aneurysms remain unknown. The aim of this study was to evaluate the clinical and long-term angiographic results of wide-necked intracranial aneurysms treated with coil embolization. Methods : Between January 2002 and December 2012, 53 wide-necked aneurysms treated with coil embolization were selected. Forty were female, and 13 were male. Twenty eight (52.8%) were ruptured aneurysms, and 25 (47.2%) were unruptured aneurysms. The patents' medical and radiological records were reviewed retrospectively. Results : Of the 53 aneurysms, coiling alone was employed in 45 (84.9%) and stent-assisted coiling was done in 8 (15.1%). The initial angiographic results revealed Raymond class 1 (complete occlusion) in 30 (56.6%) cases, Raymond class 2 (residual neck) in 18 (34.0%) cases, and Raymond class 3 (residual sac) in 5 (9.4%) cases. The mean angiographic follow-up period was 37.9 months (12-120 months). At the last angiographies, Raymond class 1 was seen in 26 (49.1%) cases, Raymond class 2 in 16 (30.2%), and Raymond class 3 in 11 (20.8%). Angiographic recurrence occurred in 22 (41.5%) patients, with minor recurrence in 7 (13.2%) cases and major recurrence in 15 (28.3%). Retreatment was performed in 8 cases (15.1%). A suboptimal result on the initial angiography was a significant predictor of recurrence in this study (p=0.03). Conclusion : The predictor of recurrence in wide-necked aneurysms is a suboptimal result on the initial angiography. Long-term angiographic follow-up is recommended in wide-necked aneurysms.

Outcomes of Stent-Assisted Coiling Using the Neuroform Atlas Stent in Unruptured Wide-Necked Intracranial Aneurysms

  • Kwon, Ohyuk;Chung, Joonho
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권1호
    • /
    • pp.23-29
    • /
    • 2021
  • Objective : Although stent-assisted coiling (SAC) has been reported to be safe and effective in treating wide-necked aneurysms, the technique has procedure-related complications. Thus, we reported our experiences of SAC using the Neuroform Atlas stent in treating wide-necked aneurysms and evaluated the incidence of and risk factors for procedure-related complications. Methods : From March 2018 to August 2019, we treated 130 unruptured wide-necked aneurysms in 123 patients with Neuroform Atlas stents. Angiographic results and clinical outcomes were reviewed retrospectively. Clinical and angiographic follow-up were performed in all cases (mean, 12.4 months) after the procedure. Results : There were eight cases (6.2%) of procedure-related complications (two dissections, five thromboembolisms, and one hemorrhage) and two (1.5%) of delayed complications (one ischemia and one hemorrhage). There was one case (0.8%) of failure of stent deployment and one (0.8%) of suboptimal positioning of the stent. Follow-up angiography showed complete obliteration in 103 (79.2%), residual neck in 16 (12.3%), and residual aneurysm in 11 cases (8.5%). Aneurysm locations in the middle cerebral artery (odds ratio [OR], 2.211; p=0.046) and the anterior communicating artery (OR, 2.850; p=0.039) were associated with procedure-related complications on univariate analysis. However, no independent risk factor for procedure-related complications was noted in multivariate analysis. Conclusion : The Neuroform Atlas showed a high rate of technical success. Good clinical and radiographic outcomes in early follow-up suggests that the device is feasible and safe. SAC of aneurysms on the middle cerebral artery or anterior communicating artery may require more attention to prevent possible procedure-related complications.

Computational Analysis of Impulse Forces Affecting Coil Compaction in Cerebral Aneurysms

  • Cha Kyung-Se;Balaras Elias
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권3호
    • /
    • pp.94-100
    • /
    • 2006
  • The effectiveness of the treatment of intracranial aneurysms with endovascular coiling depends on coil packing density, the location of aneurysm, its neck dimensions with respect to the aneurysm dome, and its size with respect to the surrounding tissue. Clinical data also suggests that the aneurysm neck size is the main predictor of aneurysm recanalization. In this study, the force impinging on the aneurysm neck in an idealized aneurysm was calculated by using a three dimensional finite volume method for the non-Newtonian incompressible laminar flow. To quantify the effect of neck size on the impingement force, calculations were performed for aneurysm neck diameters (Da) varying from 10% to 100% of the parent artery diameter (Dp). Also, maximum impingement forces were represented by a function of the ratio of the aneurysm neck to the diameter of the parent vessel. The results show that the hemodynamic forces exerted on the coil mass at the aneurysm neck due to the pulsatile blood flow are larger for wide necked aneurysms.

In-Stent Stenosis of Stent-Assisted Coil Embolization of the Supraclinoid Internal Carotid Artery Aneurysm

  • Lee, Jae-Il;Ko, Jun-Kyeung;Choi, Byung-Kwan;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권6호
    • /
    • pp.370-373
    • /
    • 2012
  • The intracranial stent functions primarily to prevent protrusion of coils into the parent vessel during the embolization of wide-necked cerebral aneurysms and might also reduce aneurysm recanalization rate. In spite of these advantages, little is known about the long-term interaction of the stent with the parent vessel wall. We present a rare case of severe in-stent stenosis occurring as a delayed complication of Neuroform stent-assisted coil embolization of an unruptured intracranial aneurysm.

Solitaire AB Stent-Assisted Coiling of Wide-Neck Micro Aneurysms

  • Li, Xue-dong;Qin, Jun;Xiao, Zhen-yong;Feng, Yi;Chen, Jia-kang
    • Journal of Korean Neurosurgical Society
    • /
    • 제59권4호
    • /
    • pp.341-345
    • /
    • 2016
  • Objective : Solitaire AB stent-assisted coiling facilitates the endovascular treatment of wide-necked intracranial aneurysms. We present our experience of coiling the micro-aneurysms of wide-neck with Solitaire AB stent assisting in a single center. Methods : Thirty-one Solitaire AB stents were used to treat via endovascular approach patients with 31 wide-neck micro aneurysms in a single center in China. Technical and clinical complications were recorded. Modified Rankin Scale was used to evaluate the patients' conditions via clinic and telephone follow-up. Results : The mean width of aneurysm sac was $2.30{\pm}0.42mm$, and the mean diameter of aneurysm neck was $2.83{\pm}.48mm$. Complete occlusion was achieved in 28 aneurysms (90.32%); neck remnant was seen in 3 aneurysms (9.68%). Technical and clinical complications related to the procedure were encountered in four patients (12.5%). Two patients died (6.25%). No patient had a permanent deficit. Conclusion : Solitaire AB stent was a safe and efficiency tool in assisting coiling of micro aneurysms with wide neck, but may be not suitable for a blaster-like one. Mid- and long-term follow-up will be required to elucidate the impact of the Solitaire AB stent on recanalization rate.

Comparison of Long-Term Angiographic Results of Wide-Necked Intracranial Aneurysms : Endovascular Treatment with Single-Microcatheter Coiling, Double-Microcatheter Coiling, and Stent-Assisted Coiling

  • Kim, Hyun Sik;Cho, Byung Moon;Yoo, Chan Jong;Choi, Dae Han;Hyun, Dong Keun;Shim, Yu Shik;Song, Joon Ho;Oh, Jae Keun;Ahn, Jun Hyong;Kim, Ji Hee;Chang, In Bok
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권5호
    • /
    • pp.751-762
    • /
    • 2021
  • Objective : Endovascular treatment of intracranial aneurysms is challenging in case of wide-necked aneurysms because coils are prone to herniate into the parent artery, causing thromboembolic events or vessel occlusion. This study aims to compare long-term angiographic results of wide-necked aneurysms treated by stent-assisted, double-microcatheter, or single-microcatheter groups. Methods : Between January 2003 and October 2016, 108 aneurysms that were treated with endovascular coil embolization with a neck size wider than 4 mm and a follow-up period of more than 3 years were selected. We performed coil embolization with single-microcatheter, double-microcatheter, and stent-assisted techniques. Angiographic results were evaluated using the Raymond-Roy occlusion classification (RROC). All medical and angiographic records were reviewed retrospectively. Results : Clinical and angiographic analyses were conducted in 108 wide-necked aneurysms. The immediate post-procedural results revealed RROC class I (complete occlusion) in 66 cases (61.1%), class II (residual neck) in 36 cases (33.3%), and class III (residual sac) in six cases (5.6%). The final follow-up results revealed class I in 48 cases (44.4%), class II in 49 cases (45.4%), and class III in 11 cases (10.2%). Of a total of 45 (41.6%) radiologic recurrences, there were 21 cases (19.4%) of major recurrence that required additional treatment, and 24 cases (22.2%) of minor recurrence. The final follow-up angiographic results showed statistically significant differences between the stent-assisted group and the others (p<0.01). Conclusion : Long-term follow-up angiography demonstrated that the stent-assisted technique had a better complete occlusion rate than the other two techniques.