References
- Baxter BW, Rosso D, Lownie SP : Double microcatheter technique for detachable coil treatment of large, wide-necked intracranial aneurysms. AJNR Am J Neuroradiol 19 : 1176-1178, 1998
- Cai K, Zhang Y, Shen L, Ni Y, Ji Q : Comparison of stent-assisted coiling and balloon-assisted coiling in the treatment of ruptured wide-necked intracranial aneurysms in the acute period. World Neurosurg 96 : 316-321, 2016 https://doi.org/10.1016/j.wneu.2016.09.029
- Chalouhi N, Starke RM, Koltz MT, Jabbour PM, Tjoumakaris SI, Dumont AS, et al. : Stent-assisted coiling versus balloon remodeling of wide-neck aneurysms: comparison of angiographic outcomes. AJNR Am J Neuroradiol 34 : 1987-1992, 2013 https://doi.org/10.3174/ajnr.A3538
- Chung EJ, Shin YS, Lee CH, Song JH, Park JE : Comparison of clinical and radiologic outcomes among stent-assisted, double-catheter, and balloon-assisted coil embolization of wide neck aneurysms. Acta Neurochir (Wien) 156 : 1289-1295, 2014 https://doi.org/10.1007/s00701-014-2104-y
- Consoli A, Vignoli C, Renieri L, Rosi A, Chiarotti I, Nappini S, et al. : Assisted coiling of saccular wide-necked unruptured intracranial aneurysms: stent versus balloon. J Neurointerv Surg 8 : 52-57, 2016 https://doi.org/10.1136/neurintsurg-2014-011466
- Durst CR, Starke RM, Gaughen JR Jr, Geraghty S, Kreitel KD, Medel R, et al. : Single-center experience with a dual microcatheter technique for the endovascular treatment of wide-necked aneurysms. J Neurosurg 121 : 1093-1101, 2014 https://doi.org/10.3171/2014.7.JNS132237
- Farrell B, Godwin J, Richards S, Warlow C : The United Kingdom transient ischaemic attack (UK-TIA) aspirin trial: final results. J Neurol Neurosurg Psychiatry 54 : 1044-1054, 1991 https://doi.org/10.1136/jnnp.54.12.1044
- Fernandez Zubillaga A, Guglielmi G, Vinuela F, Duckwiler GR : Endovascular occlusion of intracranial aneurysms with electrically detachable coils: correlation of aneurysm neck size and treatment results. AJNR Am J Neuroradiol 15 : 815-820, 1994
- Fisher CM, Kistler JP, Davis JM : Relation of cerebral vasospasm to subarachnoid hemorrhage visualized by computerized tomographic scanning. Neurosurgery 6 : 1-9, 1980 https://doi.org/10.1227/00006123-198001000-00001
- Gory B, Klisch J, Bonafe A, Mounayer C, Beaujeux R, Moret J, et al. : Solitaire AB stent-assisted coiling of wide-necked intracranial aneurysms: mid-term results from the SOLARE study. Neurosurgery 75 : 215-219; discussion 219, 2014 https://doi.org/10.1227/NEU.0000000000000415
- Higashida RT, Smith W, Gress D, Urwin R, Dowd CF, Balousek PA, et al. : Intravascular stent and endovascular coil placement for a ruptured fusiform aneurysm of the basilar artery. Case report and review of the literature. J Neurosurg 87 : 944-949, 1997 https://doi.org/10.3171/jns.1997.87.6.0944
- Huang DZ, Jiang B, He W, Wang YH, Wang ZG : Risk factors for the recurrence of an intracranial saccular aneurysm following endovascular treatment. Oncotarget 8 : 33676-33682, 2017 https://doi.org/10.18632/oncotarget.16897
- Hunt WE, Hess RM : Surgical risk as related to time of intervention in the repair of intracranial aneurysms. J Neurosurg 28 : 14-20, 1968 https://doi.org/10.3171/jns.1968.28.1.0014
- Ishihara H, Ishihara S, Niimi J, Neki H, Kakehi Y, Uemiya N, et al. : Risk factors for coil protrusion into the parent artery and associated thrombo-embolic events following unruptured cerebral aneurysm embolization. Interv Neuroradiol 21 : 178-183, 2015 https://doi.org/10.1177/1591019915582375
- Lee SJ, Cho YD, Kang HS, Kim JE, Han MH : Coil embolization using the self-expandable closed-cell stent for intracranial saccular aneurysm: a single-center experience of 289 consecutive aneurysms. Clin Radiol 68 : 256-263, 2013 https://doi.org/10.1016/j.crad.2012.07.017
- Lee SY, Chae KS, Rho SJ, Choi HK, Park HS, Ghang CG : Clinical and angiographic outcomes of wide-necked aneurysms treated with the solitaire AB stent. J Cerebrovasc Endovasc Neurosurg 15 : 158-163, 2013 https://doi.org/10.7461/jcen.2013.15.3.158
- Lubicz B, Lefranc F, Bruneau M, Baleriaux D, De Witte O : Balloonassisted coiling of intracranial aneurysms is not associated with a higher complication rate. Neuroradiology 50 : 769-776, 2008 https://doi.org/10.1007/s00234-008-0397-3
- Medical Advisory Secretariat : Coil embolization for intracranial aneurysms: an evidence-based analysis. Ont Health Technol Assess Ser 6 : 1-114, 2006
- Moret J, Cognard C, Weill A, Castaings L, Rey A : The "remodelling technique" in the treatment of wide neck intracranial aneurysms. angiographic results and clinical follow-up in 56 cases. Interv Neuroradiol 3 : 21-35, 1997 https://doi.org/10.1177/159101999700300103
- Murayama Y, Nien YL, Duckwiler G, Gobin YP, Jahan R, Frazee J, et al. : Guglielmi detachable coil embolization of cerebral aneurysms: 11 years' experience. J Neurosurg 98 : 959-966, 2003 https://doi.org/10.3171/jns.2003.98.5.0959
- Nelson PK, Levy DI : Balloon-assisted coil embolization of wide-necked aneurysms of the internal carotid artery: medium-term angiographic and clinical follow-up in 22 patients. AJNR Am J Neuroradiol 22 : 19-26, 2001
- Raymond J, Guilbert F, Weill A, Georganos SA, Juravsky L, Lambert A, et al. : Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils. Stroke 34 : 1398-1403, 2003 https://doi.org/10.1161/01.STR.0000073841.88563.E9
- Raymond J, Roy D : Safety and efficacy of endovascular treatment of acutely ruptured aneurysms. Neurosurgery 41 : 1235-1245; discussion 1245-1246, 1997 https://doi.org/10.1097/00006123-199712000-00002
- Roy D, Milot G, Raymond J : Endovascular treatment of unruptured aneurysms. Stroke 32 : 1998-2004, 2001 https://doi.org/10.1161/hs0901.095600
- Shapiro M, Becske T, Sahlein D, Babb J, Nelson PK : Stent-supported aneurysm coiling: a literature survey of treatment and follow-up. AJNR Am J Neuroradiol 33 : 159-163, 2012 https://doi.org/10.3174/ajnr.A2719
- Sluzewski M, van Rooij WJ, Beute GN, Nijssen PC : Balloon-assisted coil embolization of intracranial aneurysms: incidence, complications, and angiography results. J Neurosurg 105 : 396-399, 2006 https://doi.org/10.3171/jns.2006.105.3.396
- Song JH, Chang IB, Ahn JH, Kim JH, Oh JK, Cho BM : Angiographic results of wide-necked intracranial aneurysms treated with coil embolization : a single center experience. J Korean Neurosurg Soc 57 : 250-257, 2015 https://doi.org/10.3340/jkns.2015.57.4.250
- Starke RM, Durst CR, Evans A, Ding D, Raper DM, Jensen ME, et al. : Endovascular treatment of unruptured wide-necked intracranial aneurysms: comparison of dual microcatheter technique and stent-assisted coil embolization. J Neurointerv Surg 7 : 256-261, 2015 https://doi.org/10.1136/neurintsurg-2014-011159
- Taylor RA, Callison RC, Martin CO, Hayakawa M, Chaloupka JC : Acutely ruptured intracranial saccular aneurysms treated with stent assisted coiling: complications and outcomes in 42 consecutive patients. J Neurointerv Surg 2 : 23-30, 2010 https://doi.org/10.1136/jnis.2009.001693