• Title/Summary/Keyword: Internal gap

Search Result 412, Processing Time 0.027 seconds

A Study on the Reasons of Development Gap in Rural Community Development : The Application of Neo-Endogenous Development (농촌마을 발전 격차의 원인에 대한 연구: 신내생적 발전론의 적용)

  • Kim, Tae-Yeon
    • Korean Journal of Organic Agriculture
    • /
    • v.28 no.1
    • /
    • pp.69-93
    • /
    • 2020
  • The paper is to compare two villages in Songak-myeon, Asan, Cnungnam Province in Korea. It tries to show how the joint village project, which began with the support of the same external organization, produces different results depending on the internal conditions and circumstances of the village. From the end of the 1990s, Pyeongchon-ri and Sugok-ri started developing villages under the influence of the environmentally friendly farming movement. And subsequent supports were provided by local organizations for the development of the village. However, the village project in Sugok-ri, which focused on economic performance, later turned out to be a failure, and the residents changed to pursue activities for their own economic interests individually. On the other hand, In Pyeongchon-ri, the cooperation among villagers was strengthened in implementing support projects by similar external agencies. In addition, community ties and identity have been strengthened as problems have been solved through cooperation among residents in the process of promoting the village project. Nevertheless, projects undertaken in Pyeongchon-ri for the purpose of increasing economic performance was all failed. Through these findings, the paper asserts that the neo-endogenous development approach utilizing external support on the basis of internal cooperative network among villagers must be a very useful method for rural development in contemporary societies.

A Study on Design Sensitivity of Elastomeric O-ring Squeezed and Highly Pressurized Under Laterally One-sided Constrained Condition (단 측벽 구속하에서 압축 및 내압을 받는 고무 오링의 설계 민감도 연구)

  • Park, Sung-Han;Kim, Jae-Hoon;Kim, Won-Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.6
    • /
    • pp.27-34
    • /
    • 2007
  • Static or dynamic elastomeric O-ring seals are installed between joining parts, and play key roles of high pressure-tightening. Sealing performance and structural safety of the O-ring are dependent on groove design, plain diameter, squeeze and applications such as pressure and temperature. In this study, to solve O-ring problem squeezed and highly pressurized under laterally one-sided constrained condition, hyperelastic FE analyses are performed, and FE results are compared with measured ones by computer-aided tomography, deformed shape and extrusion depth of the O-ring. Through the comparisons, FE analysis technique was verified. In order to evaluate design sensitivity, Taguchi method was used to select FE analysis cases. Adjustment parameters are clearance gap, groove comer radius, plain diameter and squeeze. By means of verified FE analysis technique, it has been analysed how the parameters have effects on contact stress fields, internal stress fields, and extrusion depths. Sealing performance has been evaluated based on contact stress fields and contact widths, and structural safety on internal stress and strain, extrusion lengths.

Structures and Barrier Heights for the Internal Rotation of Ethyl Halides Caculated by ab initio Methods

  • Ryu, Ung-Sik;Lee, Yoon-Sup
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.3
    • /
    • pp.221-227
    • /
    • 1994
  • The barrier heights of the internal rotations for ethyl halides calculated by ab initio methods differ from those of experiments by more than 0.2 kcal/mol. The use of basis sets larger than the $6-31G^{\ast}$ set and the inclusion of correlation do not improve the agreement between the calculated and experimental values. The zero-point vibration corrections are substantial in the HF calculations with $6-31G^{\ast}$ basis sets, but become negligible in the MP2 calculations with $6-311G^{{\ast}{\ast}}$ basis sets for $C_2H_5F\;and\;C_2H_5Cl$. It is shown that the rigid rotor approximation and the assumed shape of the potential curve as a cos2${\theta}$ curve could also be the sources of discrepancies between calculated and experimental values. Higher order perturbation corrections narrow the gap between experimental and theoretical values, but there still remains about 10% overestimate of 0.3 kcal/mol. Optimized geometries from the HF and MP2 calculations are in good agreement with those from experiments. Dipole moments calculated from the MP2 densities show slightly better agreement with experiments than those from the HF densities.

Development of Digital-Image-Correlation Technique for Detecting Internal Defects in Simulated Specimens of Wind Turbine Blades (풍력 블레이드 모의 시편의 내부 결함 검출을 위한 이미지 상관법 기술 개발)

  • Hong, Kyung Min;Park, Nak Gyu
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.5
    • /
    • pp.205-212
    • /
    • 2020
  • In the performance of a wind turbine system, the blades play a vital role. However, they are susceptible to damage arising from complex and irregular loading (which may even cause catastrophic collapse), and they are expensive to maintain. Therefore, it is very important both to find defects after blade manufacturing is completed and to find damage after the blade is used for a certain period of time. This study provides a new perspective for the detection of internal defects in glass-fiber- and carbon-fiber-reinforced panels, which are used as the main materials in wind turbine blades. A gap or fracture between fiber-reinforced materials, which may occur during blade manufacturing or operation, is simulated by drilling a hole 5 mm in diameter in the middle layer of the laminated material. Then, a digital-image-correlation (DIC) method is used to detect internal defects in the blade. Tensile load is applied to the fabricated specimen using a tensile tester, and the generated changes are recorded and analyzed with the DIC system. In the glass-fiber-reinforced laminated specimen, internal defects were detected from a strain value of 5% until the end of the experiment, while in the case of the carbon-fiber-reinforced laminated specimen, internal defects were detected from 1% onward. It was proved using the DIC system that the defect was detected as a certain level of strain difference developed around the internal defects, according to the material properties.

Computational Fluid Dynamic Modeling for Internal Antenna Type Inductively Coupled Plasma Systems (CFD를 이용한 내장형 안테나 유도 결합 플라즈마 시스템 모델링)

  • Joo, Jung-Hoon
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.3
    • /
    • pp.164-175
    • /
    • 2009
  • CFD is used to analyze gas flow characteristics, power absorption, electron temperature, electron density and chemical species profile of an internal antenna type inductively coupled plasma system. An optimized grid generation technology is used for a complex real-scale models for industry. A bare metal antenna shows concentrated power absorption around rf a feeding line. Skin depth of power absorption for a system is modeled to 50 mm, which is reported 53 mm by experiments. For an application of bipolar plates for hydrogen fuel cells, multi-sheet loading ICP nitriding system is proposed using an internal ICP antenna. It shows higher atomic nitrogen density than reported simple pulsed dc nitriding systems. Minimum gap between sheets for uniform nitriding is modeled to be 39 mm.

Correlation between Analytic and Experimental Results on Inelastic Behavior of Reinforced Concrete Frame

  • Lee, Han-Seon;Kim, Sang-Dae;Park, Cheol-Yong;Ko, Dong-Woo
    • International Journal of Concrete Structures and Materials
    • /
    • v.18 no.3E
    • /
    • pp.173-181
    • /
    • 2006
  • The objectives of this study are to evaluate the reliability of an existing nonlinear analysis program for predicting the inelastic behavior of reinforced concrete frame with seismic details and to observe the redistribution of the internal forces, which can not be easily measured by an experiment. In order to carry out this task, the nonlinear analysis program of IDARC 2D(3) was run on a 2-bay, 2-story moment-resisting reinforced concrete plane frame with seismic details. (1) The effort to obtain the results of the analysis similar to those of experiment was made by determining the appropriate values of model parameters. The comparison of the analysis results with those of experiment and the observation of the distribution of internal forces obtained through nonlinear analysis points to the following conclusions. (1) The overall relationship between lateral load and lateral displacement given by the analysis is similar to that of experiment. However, the values of initial stiffness and the amount of energy dissipation in the initial displacement steps given by the analysis show larger values than those of experiment. (2) The analysis provided detailed information on the distribution and redistribution of internal forces and proved useful in elucidating the crack pattern, the sequence of the occurrence of plastic hinges, and the failure or yielding mechanism for the whole structure. (3) In spite of the similarity in overall behavior of analysis and experiment, there exists a significant discrepancy in some local behaviors. Furthermore, the hysteresis in the relationship between moment and curvature in some column ends have shown sudden deteriorations in strength, which can not be interpreted satisfactorily at the present time. Therefore, it is necessary to develop a better analytical model to fill this knowledge gap.

Compressibility Effect in the Axisymmetric Internal Flow Past a Microgap (미세 간극을 지나는 축대칭 내부 유동의 압축성 효과 분석)

  • Kim, Seong-Soo;Chang, Se-Myong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.12
    • /
    • pp.1061-1069
    • /
    • 2010
  • In this study, a simplified axisymmetric model is proposed for the problem of compressible internal flow past a microgap. Using numerical and experimental methods, the phenomena of choked flows are observed; these flows are induced by the acceleration of subsonic flows past the narrow cross-section of an annular shape made by a microgap. The relation between mass flow rate and differential pressure is obtained, and by comparing the result with experimental results, the reliability of the numerical results is discussed. The generation of a supersonic jet flow and its diffraction are visualized by performing the numerical analysis of axisymmetric compressible Navier-Stokes equations. This investigation greatly extends the physical understanding of the axisymmetric compressible flow, which has a wide range of engineering applications, e.g., in the case of valves in automotive power systems.

A Study on Electroreflectance in Si-Doped $Al_{0.33}Ga_{0.67}As$ (Si이 첨가된 $Al_{0.33}Ga_{0.67}As$에서의 Electroreflectance에 관한 연구)

  • 김근형;김동렬;김종수;김인수;배인호;한병국
    • Electrical & Electronic Materials
    • /
    • v.10 no.7
    • /
    • pp.692-699
    • /
    • 1997
  • The silicon doped $Al_{0.33}$G $a_{0.67}$As were grown by molecular beam epitaxy. The electroreflectance(ER) spectra of Schottky barrier Au/n-Al/suu x/G $a_{1-x}$ As have been measured at various modulation voltage( $V_{ac}$ ) and dc bias voltage( $V_{bias}$). From the observed Franz-Keldysh oscillations(FKO) peak, the band gap energy of the $Al_{x}$G $a_{1-x}$ As is 1.91 eV which corresponds to an Al composition of 33%. The internal electric field( $E_{i}$)of this sample is 2.96$\times$10$^{5}$ V/cm. As the modulation voltage( $V_{ac}$ ) is changed, the line shape of ER signal does not change but its amplitude varies linearly. The amplitude as a function of modulation voltage has saturated at 0.8 V. The internal electric field has decreased from 6.47$\times$10$^{5}$ V/cm to 2.00$\times$10$^{5}$ V/cm as the dc bias voltage( $V_{bias}$) increases from -3.5 V to +0.8 V. The values of built-in voltage( $V_{bi}$ ) and carrier concentration(N) determined from the plot of $V_{bias}$ from the plot of $V_{bias}$ versus $E_{i}$$^{2}$ are 0.855 V and 3.83$\times$10$^{17}$ c $m^{-3}$ , respectively.ively.y.y.y.

  • PDF

COMPARISON OF CANAL FILLING EFFICIENCY ON THE INTERNALLY RESORBED ROOT ACCORDING TO CANAL FILLING TEHNIQUES (근관충전방법에 따른 내흡수 치근의 근관충전 효율성 비교)

  • Ha, Sang-Yoon;Shin, Dong-Hoon;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.789-801
    • /
    • 1995
  • Canals with artificially made internal resorption were filled with 4 techniques(Lateral condensation, Ultrafil, Obtura II, Thermafil) to compare the efficacy of canal filling according to the filling techniques. After canal filling, radiographic examination, dye penetration through the apical portion and percentage of G-P filled area on the internal resorption area were evaluated. To examine the degree of crystal-like structure and the interface between filled G-P and canal wall, SM and SEM images were taken too. The results were as follows : 1. There was no statistically significant difference in apical microleakage among the 4 root canal filling techniques. 2. As a result of radiographic examination, Ultrafil was the best and Obtura II was acceptable but Lateral condensation and Thermafil showed unfavorable canal filling pattern similarly. 3. Ultrafil filled most of artificially made internal resorption area and Obtura II, Lateral condensation, Thermafil in that order filled unfavorably. 4. Degree of crystal like structure was the highest in the group filled with Ultrafil and those of Obtura II and Thermafil were similar and that of gutta percha used in Lateral condensation showed the lowest value. 5. Penetration of gutta percha into the dentinal tubules couldn't be seen in all groups. In the contact surface between the filled G-P and the canal wall, Lateral condensation showed relatively close sealing, Obtura II and Thermafil had irregular contact surface and Ultrafil showed regular filling pattern. 6. Contact surface between the core of Thermafil and the gutta percha showed close relationship without gap formation.

  • PDF

Comparison of blood electrolyte and biochemical parameters between single infections of rotavirus and Cryptosporidium parvum in diarrheic Hanwoo calves

  • Seungmin, Ha;Seogjin, Kang;Kwang-Man, Park;Ji-Yeong, Ku;Kyoung-Seong, Choi;Jinho, Park
    • Journal of Veterinary Science
    • /
    • v.23 no.6
    • /
    • pp.85.1-85.11
    • /
    • 2022
  • Background: Neonatal calf diarrhea is a major problem in the cattle industry worldwide. Rotavirus and Cryptosporidium parvum are the primary causative agents, especially during the first three weeks of the calf's life. Objectives: This study investigated the differences in acid-base, electrolytes, and biochemical parameters of diarrheic calves with infection of either rotavirus or C. parvum. Methods: A total of 61 Korean native calves (≤ 20 days old) were divided into two groups based on rotavirus or C. parvum infections: rotavirus infection (n = 44) and C. parvum infection (n = 17). The calves with at a specific blood pH range (pH 6.92-7.25) were chosen for comparison. The acid-base, electrolyte, chemistry, and serum proteins were analyzed, Further, fecal examinations were performed. Results: Compared to C. parvum-infected calves, the rotavirus-infected calves showed lower levels of total carbon dioxide, bicarbonate (HCO3-), anion gap, total protein, and albumin/globulin ratio, and significantly lower levels of potassium, globulin, and α2-globulin (p < 0.05). The C. parvum-infected calves (r = 0.749) had stronger correlations between pH and HCO3- than the rotavirus-infected calves (r = 0.598). Compared to rotavirus-infected calves, strong correlations between globulin and α2-globulin, α2-globulin and haptoglobin were identified in C. parvum-infected calves. Conclusions: This study is the first to investigate acid-base, electrolyte, and biochemical parameters in calves in response to infections of rotavirus and C. parvum. Although rotavirus and C. parvum cause malabsorptive and secretory diarrhea in similar-aged calves, blood parameters were different. This would help establish the diagnostic and treatment strategies.