• 제목/요약/키워드: Internal Temperature & Humidity

검색결과 154건 처리시간 0.026초

양생직후 초기재령의 콘크리트 내부 온도와 상대습도의 측정 및 분석 (Investigation of Internal Temperature and Relative Humidity of Concrete Immediately After Mix and Placement)

  • 박철우;박영훈;박용걸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1065-1068
    • /
    • 2008
  • Concrete is still one most common construction materials even in railway structures. As structures become massive and mega-sized, the importance of early age concrete quality control becomes more significant. Among various factors, relative humidity and temperature are the primary factors governing the early age quality. Temperature raise due to cement hydration causes stress, which can develop to cracking with internal and/or external restraints. Exposure conditions including ambient temperature, humidity and wind also significantly affect the cracking behavior of early age concrete. Among many of studies on the early age concrete behavior, investigation on the variation of temperature and relative humidity internal of concrete is not common. That is in part because the difficulties in measuring the relative humidity and temperature inside the concrete. This study used a digital sensor with an appropriate logger to measure internal temperature and relative humidity. This direct measuring method is expected to provide more reliable and comprehensive data acquisition on the early age behavior of concrete.

  • PDF

초기재령 콘크리트의 역학적 특성 및 온·습도 거동 특성 분석 (Mechanical Behavior and Characteristics of Internal Temperature and Relative Humidity of Concrete at Early Age)

  • 박철우;이봉학;홍성기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권6호
    • /
    • pp.184-194
    • /
    • 2011
  • 이 연구에서는 콘크리트 초기재령시의 역학적 특성을 분석하고 수화반응 및 발열반응으로 인한 콘크리트 내부에서 발생하는 온도 및 상대습도의 변화에 대한 분석을 실시하고자 하였다. 세 가지의 다른 단위시멘트량을 실험변수로 하였으며, 타설 직후부터 콘크리트 내부의 온도 및 상대습도의 변화 계측하기 위하여 새로운 계측시스템을 개발하였다. 단위시멘트량에 압축, 인장 및 휨강도의 변화는 크지 않았으며, 재령 7일 이후에는 증가가 많지 않았다. 각 측정부위별 최고 온도는 타설 후 약 11시간 정도 경과시에 발생되었으며 이후 점차 온도가 낮아지다가 양생 1일 경과 후 거푸집 탈형 이후부터 온도가 하강하기 시작했다. 각 측정부위별, 온도감소 분석 결과, 콘크리트 구조물의 위치 및 노출조건에 따라 온도의 변화가 굉장히 다른 것으로 분석되었으며, 초기재령에서 콘크리트 내부의 상대습도의 변화는 수화반응에 영향을 미치는 단위시멘트량 보다는 외부에 노출된 상태가 더 큰 영향을 미칠 수 있는 것으로 분석되었다.

CCTV통신용 함체내의 항온항습 자동제어 장치 개발 (Internal communication as CCTV Automatic Climate Control System Development)

  • 김희철
    • 한국전자통신학회논문지
    • /
    • 제10권4호
    • /
    • pp.433-439
    • /
    • 2015
  • CCTV용 함체 내부는 일정한 습도와 온도를 유지시켜 습윤에 의한 단락방지, 온도차에 의한 결로방지, 고온방지 등의 항온항습장치가 요구되며 이를 대응한 함체에 최적화된 형태와 구조, 에너지활용 정도의 항온항습 자동제어장치개발이 필요하다. 함체내부에 있는 고가의 영상장비를 온도 변환에 따른 해저드로부터 장치보호, 단락사고를 예방할 수 있는 항온항습 제어장치가 필요하다. 이는 영상기록 및 현장상황에 신뢰성 있는 영상의 저장 및 전송을 위한 부속장치가 절대적으로 요구되는 시스템이다.

피드빈 온습도 관리에 미치는 환기 시스템의 영향 (Feed Bin impact of ventilation on the temperature and humidity management)

  • 김정혁
    • 한국산학기술학회논문지
    • /
    • 제16권9호
    • /
    • pp.6432-6438
    • /
    • 2015
  • 본 논문에서는 피드빈 내부의 온도와 습도를 계측하여 분석하고, NV, EA, SA, $SA{\cdot}EA$환기 시스템을 적용하여 효율적인 관리와 운영방향을 제안한다. 외부기온과 상대습도에 따른 피드빈 내부온도와 습도의 변화를 확인하기 위해 사료 투입 기간과 투입하지 않은 기간을 대상으로 환기시스템을 적용한 후 비교분석 한다. 외부기온과 상대습도의 비교분석을 통해 내부온도는 $SA{\cdot}EA$, 내부습도는 NV, SA환기시스템의 적용과 효율을 확인할 수 있다.

자체여압 형 항공기용 저장조의 온도 및 습도에 따른 내부압력 변화에 관한 실험적 연구 (An Experimental Study on the Effect of Temperature and Humidity on the Pressure Change of the Bootstrap type Reservoir in the Aircraft)

  • 김정식;유한식;박동기
    • 한국기계가공학회지
    • /
    • 제12권5호
    • /
    • pp.170-175
    • /
    • 2013
  • For this study, the domestically developed bootstrap reservoir of the aircraft is set up in accordance with the temperature and humidity conditions depicted on the qualification test, and the variation in the internal pressure of the bootstrap reservoir of the aircraft is examined. The study shows that the bootstrap reservoir has less variation in the internal pressure at room temperature than at low temperature($-40^{\circ}C$). As a result, the internal pressure can be maintained stably when the temperature of working fluid in the bootstrap reservoir and the atmosphere environment is over room temperature($25^{\circ}C$). Therefore the keeping of temperature above room temperature is very important to operate the bootstrap reservoir of the aircraft properly.

상대습도계의 온도 의존성과 경년변화의 통계적 분석 (Statistical Analysis on the Temperature Dependence and Long-Term Change of Relative Humidity Sensors)

  • 김종철;최병일;우상봉;양인석
    • 센서학회지
    • /
    • 제21권6호
    • /
    • pp.420-424
    • /
    • 2012
  • We have investigated temperature dependence and long-term change of humidity measurement from 32 relative humidity sensors. The readings of the humidity sensors depended not only the reference humidity, but also temperature of the chamber. Approximately, the temperature dependence of the humidity sensor in average was 0.05 %R.H./$^{\circ}C$ in the temperature range from $5^{\circ}C$ to $55^{\circ}C$. For humidity sensors that have an internal temperature compensation circuit, the resulting temperature dependence was weaker by 20%. It should be also noted that for the humidity sensors used in this work underwent ${\pm}3$ %R.H. change per year for level of confidence of 95%. The users of relative humidity sensors may refer this value as a minimum change when they set the calibration interval of the humidity sensors.

중풍 환자 변증과 기후 요소와의 상관성에 관한 연구 (The Study of Correlation between Pattern Identification of Stroke Patients and Meteorological Elements)

  • 마미진;한창호
    • 대한한방내과학회지
    • /
    • 제30권1호
    • /
    • pp.200-211
    • /
    • 2009
  • There are many reports about correlations between meteorological elements and stroke. In Oriental medicine, it is recognized that the weather affects the human body and diseases, but there are few studies about the correlation between meteorological elements and pattern identification of stroke. 105 stroke patients classified into fire-heat pattern or dampress-phlegm pattern were registered during the study period. We took the measurement of each meteorological element (atmospheric pressure, temperature, humidity, wind speed) according to pattern identification and analyzed pattern identification into two groups according to mean of each meteorological element during the study period. Mean temperature was higher with the heat-fire pattern than with the dampness-phlegm pattern. Heat-fire pattern also had higher frequency when temperature was higher than mean temperature. There was no correlation between atmospheric pressure, relative humidity, or wind speed and pattern identification.

  • PDF

SN으로 개질된 에폭시 수지 계의 흡습열화 특성 (Humidity Absorbing Deterioration Characteristics of Modified Epoxy Resin System with SN)

  • 조영신;심미자;박수길;김상욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.421-424
    • /
    • 1996
  • Effects of humidity absorbing deterioration on AC dielectric breakdown characteristics of modified epoxy resin system with SN(succinonitrile) were investigated. As the forced humidity absorbing deterioration proceeded under high temperature and humidify, glass transition temperature increased. The dielectric breakdown strength increased and then decreased at deterioration cycles higher than 2. Not only, the increment of thermal stability but also, the physical detects such as Internal cracks and voids occurred during the humidity absorbing deterioration cycle were the main causes of the change in dielectric properties.

  • PDF

콘크리트 강도차에 따른 함수율 분포의 변동에 관한 실험적 연구 (Experimental Study on the Moisture Distribution in Concrete Specimens According to Different Compressive Strengt)

  • 박동천
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.195-196
    • /
    • 2019
  • The temperature and relative humidity in concrete change with the passage of time depending on factors such as compressive strength. They are also different depending upon internal depth of concrete. In this study, we have measured the change of the temperature and relative humidity in the concrete for two years to act as the parameters to evaluate the concrete durability and effective maintenance.

  • PDF

외기에 면한 초고층 아파트 발코니 천정 내부결로 예측 (Forecast on Internal Condensation at Balcony Ceiling of Super-high Apartment Building Faced with Open Air)

  • 최윤기;안재봉
    • 한국건설관리학회논문집
    • /
    • 제4권4호
    • /
    • pp.155-163
    • /
    • 2003
  • 최근 들어 주거공간의 기능만족과 효율성 확보를 위해 외기측에 면한 발코니 부위를 확장하는 사례가 늘어나고 있으며 특히, 최상층에 위치한 확장형 주거공간의 경우 외벽에 설치된 AL Curtain wall상부 외벽복합 Panel 이 완전 기밀하지 않음으로 인해 천정 상부측으로 낮은 외기온의 이동에 의한 실온과의 온도차에 의해 내부결로의 발생 가능성을 전혀 배제할 수는 없는 상황이다. 본 연구는 외기에 면한 초고층 아파트 최상층부의 발코니 천장내부에 있는 H-Beam(내화피복+단열재 구성)파 Parapet부위 내부결로 발생가능성에 대한 예측을 해 봄으로써 해당 공간거주자의 쾌적한 환경 만족 및 불안을 해소하는데 그 목적이 있다. 외주부를 구성하고 있는 Curtain wall Stone panel 또는 슬래브 바닥하부 등의 열적 취약공간에 대해 2차원 정상상태(온도평형) 열전도해석 Program을 이용, 온도예측과 온도분포해석을 통해 해당부위의 수증기압 분포에 따른 내부결로 예측을 실시하였다.