• Title/Summary/Keyword: Intermediate Coil

Search Result 14, Processing Time 0.034 seconds

Three-coil Magnetically Coupled Resonant Wireless Power Transfer System with Adjustable-position Intermediate Coil for Stable Transmission Characteristics

  • Chen, Xuling;Chen, Lu;Ye, Weiwei;Zhang, Weipeng
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.211-219
    • /
    • 2019
  • In magnetically coupled resonant (MCR) wireless power transfer (WPT) systems, the introduction of additional intermediate coils is an effective means of improving transmission characteristics, including output power and transmission efficiency, when the transmission distance is increased. However, the position of intermediate coils in practice influences system performance significantly. In this research, a three-coil MCR WPT system is adopted as an exemplification for determining how the spatial position of coils affects transmission characteristics. With use of the fundamental harmonic analysis method, an equivalent circuit model of the system is built to reveal the relationship between the output power, the transmission efficiency, and the spatial scales, including the axial, lateral, and angular misalignments of the intermediate and receiving coils. Three cases of transmission characteristics versus different spatial scales are evaluated. Results indicate that the system can achieve relatively stable transmission characteristics with deliberate adjustments in the position of the intermediate and receiving coils. A prototype of the three-coil MCR WPT system is built and analyzed, and the experimental results are consistent with those of the theoretical analysis.

Extremely high efficiency wireless power transfer system for EV charger (전기자동차 충전을 위한 고효율 무선전력전송 시스템)

  • Moon, SangCheol;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.155-156
    • /
    • 2015
  • This paper proposes a high efficiency wireless power transfer system with an asymmetric 4-coil resonator. It presents a theoretical analysis, an optimal design method, and experimental results. In the proposed asymmetric 4-coil system, the primary side consists of a source coil and two transmitter coils which are called intermediate coils, and in the secondary side, a load coil serves as a receiver coil. In the primary side, two intermediate coils boost the apparent coupling coefficient at around the operating frequency. Because of this double boosting effect, the system with an asymmetric 4-coil resonator has a higher efficiency than the conventional symmetric 4-coil system. The prototype operates at 90 kHz ofswitching frequency and has 200 mm of the power transmission distance between the primary side and the secondary side. An AC-DC overall system efficiency of 96.56% has been achieved at 3.3 kW of output power.

  • PDF

A Study on the Wireless Power Transfer System using Magnetic Resonance at the 1[MHz] Frequency Band (1[MHz] 대역의 자계 공명을 이용한 무선 전력 전송 장치에 관한 연구)

  • Park, Jeong-Heum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.1
    • /
    • pp.75-81
    • /
    • 2012
  • In this paper, the wireless power transfer system using the magnetic resonance was designed, analyzed by circuit analysis methode and the calculated transfer function was compared with the measured one. The self-resonant coil was made up of the commonly used capacitor which had the lumped capacitance and it enabled the stable magnetic resonance not to be affected by the circumstance. The transmission efficiency of this system was 70[%] at the 15[cm] between the transmission and receiving coil and the measured transfer function was similar to the calculated one, which means the circuit analysis methode is valid in this system. When the intermediate coils were added between the transmission and receiving coil, the transmission efficiency was increased, which produced the increase of transfer distance. In the case of the five intermediate coils adding, the 35[%] transmission efficiency was achived at the 90[cm] distance.

Design and neutronic analysis of the intermediate heat exchanger of a fast-spectrum molten salt reactor

  • Terbish, Jamiyansuren;van Rooijen, W.F.G.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2126-2132
    • /
    • 2021
  • Various research groups and private interprises are pursuing the design of a Molten Salt Reactor (MSR) as one of the Generation-IV concepts. In the current work a fast neutron MSR using chloride fuel is analyzed, specially analyzing the power production and neutron flux level in the Intermediate Heat Exchanger (IHX). The neutronic analysis in this work is based on a chloride-fuel MSR with 600 MW thermal power. The core power density was set to 100 MW m-3 with a core H/D [[EQUATION]] 1.0 amd four Intermediate Heat Exchanger (IHX). This leads to a power of 150 MW per IHX; this power is also comparable to the IHX proposed in the SAMOFAR framework. In this work, a preliminary design of a 150 MW helical-coil IHX for a chloride-fueled MSR is prepared and the fission rate, capture rate, and inelastic scatter rate are evaluated.

A Study on the Optical Emission Spectroscopy of the RF Inductive Plasma Process (RF 유도형 플라즈마 프로세스에 대한 분광학적 연구)

  • Jang, Mun-Gug;Han, Sang-Bo;Park, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.103-112
    • /
    • 2011
  • This paper is tried to analysis the optical emission spectroscopy related to the position of inductive load coil and flow rates of methane and oxygen in the RF inductive plasma process. According to the position of load coil, peak of $H_{\alpha}$, $H_{\beta}$, and CH were appeared strongly at the middle position of the coil and it decreased both direction. The electron temperature was approximately 0.9[eV] at that position. Emission intensities of $H_{\alpha}$, $H_{\beta}$, and CH increased linearly by increasing input power. In addition, intensities of $H_{\alpha}$ and $H_{\beta}$ increased by increasing the flow rate of oxygen. It might be ascribed that the oxygen species were bonded with $C_nH_m$ by suppressing the combination with hydrogen atoms. Consequently, the optimal position of the inductive coil is decided to the intermediate position between 4th and 5th turns, the wanted carbon thin-film is possible to deposit by controlling flow rates of methane and oxygen.

Pulsed field magnetization of multi-turn short-circuited stabilized double pancake HTS coil

  • Korotkov, V.S.;Krasnoperov, E.P.;Brazhnik, P.A.;Kartamyshev, A.A.;Bishaev, A.M.;Kozinsteva, M.V.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.1
    • /
    • pp.1-5
    • /
    • 2019
  • The pulsed field magnetization of the short-circuited soldered double pancake coil made of stabilized commercial high-Tc superconductor (HTS) tape is experimentally studied. The evolution of the shielding current induced by the pulsed field and the trapped field after the pulsed magnetization was measured at 77 K. It is shown that the trapped field in the coil is close to the value reached in the field cooling process and reduces weakly at 5-fold increasing of pulsed field amplitude. The current relaxation at t~2 ms after the pulse is defined by the current sharing between the tape's copper coating and the $YBa_2Cu_3O_{7-d}$ layer. In the intermediate time scale (1 s < t < 100 s) the flux creep in HTS layer dominates. At t > 100 s the current's relaxation is defined by the resistance of soldered joint between tapes.

Design of Alternating Magnetic Field Stimulator Using Duty Factor

  • Jang, Tae-Sun;Lee, Jin-Yong;Lee, Hyun-Sook;Kim, Sun-Wook;Hwang, Do-Guwn
    • Journal of Magnetics
    • /
    • v.17 no.1
    • /
    • pp.42-45
    • /
    • 2012
  • We have developed an alternating magnetic field stimulation system consisting of a switched-mode power supply and a digital control circuit which modulates a duty ratio to maintain a magnetic field intensity of a few mT even while the frequency increases up to 4 kHz with a controllable coil temperature below $30^{\circ}C$ in air. This duty ratio modulation and water circulation are advantageous for cell culture under ac-magnetic field stimulation by preventing the incubator from exceeding a cell-viable temperature of $37^{\circ}C$. Although the temperature of the coil when subjected to a sinusoidal voltage rapidly increased, that of our system modulated by the duty factor did not change. This is a potentially valuable method to investigate the effects of intermediate frequency magnetic field stimulation on biological entities such as cells, tissues and organs.

Preliminary analysis and design of the heat exchangers for the Molten Salt Fast Reactor

  • Ronco, Andrea Di;Cammi, Antonio;Lorenzi, Stefano
    • Nuclear Engineering and Technology
    • /
    • v.52 no.1
    • /
    • pp.51-58
    • /
    • 2020
  • Despite the recent growth of interest in molten salt reactor technology and the crucial role which heat transfer plays in the design of power reactors, specific studies on the design of heat exchangers for the Molten Salt Fast Reactor have not yet been performed. In this work we deliver a preliminary but quantitative analysis of the intermediate heat exchangers, based on reference design data from the SAMOFAR H2020-Euratom project. Two different promising reference technologies are selected for study thanks to their compactness features, the Printed Circuit and the Helical Coil heat exchangers. We present preliminary design results for each technology, based on simplified design tools. Results highlight the limiting effects of the compactness constraints imposed on the fuel salt inventory and the allowed size. Large pressure drops on both flow sides are to be expected, with negative consequences on pumping power and natural circulation capabilities. The small size required for the flow channels also represents possible fabrication issues and safety concerns regarding channel blockage.

Design of Wireless Electric Vehicle Charging Circuits with Intermediate Coil (보조권선을 포함하는 전기차 충전용 무선전력전송회로 설계기법)

  • Oh, Kwang-Kyo
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.161-162
    • /
    • 2016
  • 본 논문에서는 권선 사이의 자계결합도 변동을 고려하여 자기공진 방식의 보조권선을 포함하는 전기차 충전용 무선전력전송회로의 설계기법을 제시한다. 전기차 충전용 무선전력전송회로를 설계하기 위해서는 회로의 동작주파수가 표준규격에 의해서 일정범위로 제한되고 1차측과 2차측 권선의 정렬상태에 따라서 자계결합도가 변동할 수 있다는 점이 고려되어야 한다. 본 논문에서는 동작주파수의 제한범위 및 자계결합도의 변동을 고려하여 1차측에 보조권선을 포함하는 자기공진형 무선전력전송회로의 설계기법을 제시한다.

  • PDF

New Implementation Method of the Pulsed Nuclear Magnetic Resonance Apparatus (펄스방식의 핵자기 공명장치에 관한 새로운 구현방법)

  • 김청월
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.10
    • /
    • pp.1-11
    • /
    • 1998
  • This paper presents a new implementation method of the pulsed NMR(nuclear magnetic resonance) apparatus, which contains a single coil in a magnet console, to detect a NMR signal. Applying an RF magnetic field of 5MHz to the magnet console which is designed to have Larmor frequency of 5MHz for hydrogen atom, the hydrogen NMR signal was obtained from the glycerin which was put in the magnet console as a sample. The DC magnetic field in the magnet console was implemented with a permanent magnet of 1168 gauss and the RF magnetic field was generated appling an RF signal with the frequency of 5MHz and the current magnitude of 8A to a coil of 5.73${\mu}$H. The magnitude of the NMR signal was maximum when the RF magnetic field was generated for 2.8 ${\mu}$sec, and the period of generating the RF magnetic field was designed to 100msec for detecting the NMR signal repeatedly. The NMR signal, radiated from the sample in the magnetic console, was appeared as an amplitude-modulated signal with a frequency equal to the Larmor frequency. The signal, induced in the coil, was amplified in the tx/rx separation circuit, preamplifier and intermediate amplifier by a factor of 20.7dB, 36dB and 40dB, respectively, and the signal was detected by a synchronous detection circuits, then the NMR signal was obtained.

  • PDF