• 제목/요약/키워드: Interface Kit

검색결과 55건 처리시간 0.025초

A novel retentive type of dental implant prosthesis: marginal fitness of the cementless double crown type implant prosthesis evaluated by bacterial penetration and viability

  • Hong, Seoung-Jin;Kwon, Kung-Rock;Jang, Eun-Young;Moon, Ji-Hoi
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권4호
    • /
    • pp.233-238
    • /
    • 2020
  • PURPOSE. This study aims to compare the marginal fitness of two types of implant-supported fixed dental prosthesis, i.e., cementless fixation (CL.F) system and cement-retained type. MATERIALS AND METHODS. In each group, ten specimens were assessed. Each specimen comprised implant lab analog, titanium abutment fabricated with a 2-degree tapered axial wall, and zirconia crown. The crown of the CL.F system was retained by frictional force between abutment and relined composite resin. In the cement-retained type, zinc oxide eugenol cement was used to set crown and abutment. All specimens were sterilized with ethylene oxide, immersed in Prevotella intermedia culture in a 50 mL tube, and incubated with rotation. After 48 h, the specimens were washed thoroughly before separating the crown and abutment. The bacteria that penetrated into the crown-abutment interface were collected by washing with 500 µL of sterile saline. The bacterial cell number was quantified using the agar plate count technique. The BacTiter-Glo Microbial Cell Viability Assay Kit was used to measure bacterial adenosine triphosphate (ATP)-bioluminescence, which reflects the bacterial viability. The t-test was performed, and the significance level was set at 5%. RESULTS. The number of penetrating bacterial cells assessed by colony-forming units was approximately 33% lower in the CL.F system than in the cement-retained type (P<.05). ATP-bioluminescence was approximately 41% lower in the CL.F system than in the cement-retained type (P<.05). CONCLUSION. The CL.F system is more resistant to bacterial penetration into the abutment-crown interface than the cement-retained type, thereby indicating a precise marginal fit.

Strengthening of non-seismically designed beam-column joints by ferrocement jackets with chamfers

  • Li, Bo;Lam, Eddie Siu-Shu;Cheng, Yuk-Kit;Wu, Bo;Wang, Ya-Yong
    • Earthquakes and Structures
    • /
    • 제8권5호
    • /
    • pp.1017-1038
    • /
    • 2015
  • This paper presents a strengthening method that involves the use of ferrocement jackets and chamfers to relocate plastic hinge for non-seismically designed reinforced concrete exterior beam-column joints. An experimental study was conducted to assess the effectiveness of the proposed strengthening method. Four half-scale beam-column joints, including one control specimen and three strengthened specimens, were prepared and tested under quasi-static cyclic loading. Strengthening schemes include ferrocement jackets with or without skeleton reinforcements and one or two chamfers. Experimental results have indicated that the proposed strengthening method is effective to move plastic hinge from the joint to the beam and enhance seismic performance of beam-column joints. Shear stress and distortion within the joint region are also reduced significantly in strengthened specimens. Skeleton reinforcements in ferrocement provide limited improvement, except on crack control. Specimen strengthened by ferrocement jackets with one chamfer exhibits slight decrease in peak strength and energy dissipation but with increase in ductility as compared with that of two chamfers. Finally, a method for estimating moment capacity at beam-column interface for strengthened specimen is developed. The proposed method gives reasonable prediction and can ensure formation of plastic hinge at predetermined location in the beam.

Colonoscopy Training Simulator

  • Yi, S.Y.;Woo, H.S.;Kwon, J.Y.;Joo, J.K.;Lee, D.Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.57-61
    • /
    • 2005
  • This paper presents a new colonoscopy training simulator that includes a specialized haptic device and graphics algorithms to transfer haptic sensation through a long and flexible tube, and manage large number of polygons. The developed haptic device makes the colonoscope tube move along the two guiding rods in the translational direction. The torque of the roll motion is transferred by a timing belt and pulleys. A special guide is developed, which allows the force and torque from the motors to be transmitted to the user without loss. The haptic device is evaluated by physicians. One of the important skills of the colonoscopy, jiggling is incorporated for the first time by the developed sensor mechanism using photo-sensors. A colonoscope handle that shares the look, feel, and functions with the actual colonoscope, is developed with the necessary electronics inside. The number of polygons is reduced by an edge-collapse algorithm for real-time simulation. The algorithms to import CT data, to segment the colon image, to extract centerline of the colon, and to construct the colon surface, are integrated into a Colon Modeling Kit system that performs all these processes in real-time.

  • PDF

AndroScope: An Insightful Performance Analyzer for All Software Layers of the Android-Based Systems

  • Cho, Myeongjin;Lee, Ho Jin;Kim, Minseong;Kim, Seon Wook
    • ETRI Journal
    • /
    • 제35권2호
    • /
    • pp.259-269
    • /
    • 2013
  • Android has become the most popular platform for mobile devices. However, Android still has critical performance issues, such as "application not responding" errors and hiccups resulting from garbage collection. Many phone vendors have tried to resolve the problems by characterizing and improving the performance. However, there are few insightful performance analysis tools for the Android-based systems. This paper presents AndroScope, which is a performance analysis tool for both the Android platform (Dalvik virtual machine, core libraries, Android libraries, and even Linux kernels) and its applications. To the best of our knowledge, this is the first tool to collect and analyze performance data from all the software layers of the Android-based systems. AndroScope offers a trace mechanism to collect such deep and wide performance data as hardware performance counters, time, and memory usage. In addition, the tool includes TraceBridge, which is a middleware for the fast handling of mass logs. Moreover, AndroScope offers an integrated graphical user interface with the Android software development kit to display a great volume of the detailed performance data.

Verification of Reduced Order Modeling based Uncertainty/Sensitivity Estimator (ROMUSE)

  • Khuwaileh, Bassam;Williams, Brian;Turinsky, Paul;Hartanto, Donny
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.968-976
    • /
    • 2019
  • This paper presents a number of verification case studies for a recently developed sensitivity/uncertainty code package. The code package, ROMUSE (Reduced Order Modeling based Uncertainty/Sensitivity Estimator) is an effort to provide an analysis tool to be used in conjunction with reactor core simulators, in particular the Virtual Environment for Reactor Applications (VERA) core simulator. ROMUSE has been written in C++ and is currently capable of performing various types of parameter perturbations and associated sensitivity analysis, uncertainty quantification, surrogate model construction and subspace analysis. The current version 2.0 has the capability to interface with the Design Analysis Kit for Optimization and Terascale Applications (DAKOTA) code, which gives ROMUSE access to the various algorithms implemented within DAKOTA, most importantly model calibration. The verification study is performed via two basic problems and two reactor physics models. The first problem is used to verify the ROMUSE single physics gradient-based range finding algorithm capability using an abstract quadratic model. The second problem is the Brusselator problem, which is a coupled problem representative of multi-physics problems. This problem is used to test the capability of constructing surrogates via ROMUSE-DAKOTA. Finally, light water reactor pin cell and sodium-cooled fast reactor fuel assembly problems are simulated via SCALE 6.1 to test ROMUSE capability for uncertainty quantification and sensitivity analysis purposes.

MP3 스마트웨어 제품 상용화를 위한 디자인 프로토타입 개발 및 사용성 평가 연구 (Usability Evaluation and Development of Design Prototyping for MP3 Smart Clothing Product)

  • 채행석;홍지영;김준희;김진형;한광희;이주현
    • 감성과학
    • /
    • 제10권3호
    • /
    • pp.331-342
    • /
    • 2007
  • 본 연구에서는 MP3스마트웨어 상용화를 위한 디자인 프로토타입을 개발하였다. 본 연구에서 개발한 MP3 스마트웨어는 MP3 플레이어, 리모컨 모듈, 이어폰이 하나의 키트(One-kit) 형태로 되어 있으며 조립과 분리가 용이하다. 개발된 의류는 재킷타입의 MP3-YSJ(Yonsei Smart Jacket)와 사파리타입의 MP3-YSS(Yonsei Smart Safari)의 2종류의 MP3스마트웨어 였다. 2종류의 스마트웨어를 대상으로 한 두 차례의 사용성 평가가 각각 모듈별 평가와 항목별 평가로 진행되었다. 모듈별 평가는 외관, 소재, 음악컨트롤러, 이어폰/스피커, 커넥터였고 항목별 평가는 사회적 수용성,착용감,유용성,관리용이성,안전성을 평가하였다. MP3-YSJ 1.0과 MP3-YSS 1.0을 대상으로 한 1차 사용성 평가에서는 모듈별 평가는 전체적으로 긍정적인 결과를 보여주었다. 또한 항목별 평가에서는 MP3-YSJ 1.0와 MP3-YSS 1.0모두 다른 항목에 비해 사회적 수용성이 약간 낮게 평가되었고, 커넥터의 관리 용이성과 음악컨트롤러의 사회적 수용성이 낮게 나타났다. 2차 사용성 평가는 1차 사용성 평가 결과를 반영하여 개발된 제품을 대상으로 실시하였다. MP3-YSS 2.0은 음악 컨트롤러의 사회적 수용성과 관리용이성, 커넥터의 관리용이성이 개선이 필요한 항목으로 밝혀졌고, MP3-YSS 2.0의 경우에는 음악컨트롤러로의 사회적 수용성, 커넥터의 사회적 수용성, 소재의 관리용이성이 개선이 필요한 항목으로 나타났다. 특히 사용자는 키패드의 배치 때문에 사회적 수용성 측면에서 불편을 느꼈다. 음악컨트롤러의 사회적 수용성 문제를 보완하기 위해서는 음악컨트롤러의 키패드 인터페이스에 대해 보다 구체적인 연구가 필요하다.

  • PDF

3D-프린팅 의치상 레진과 열중합 의치상 레진에서의 의치 첨상 재료 간의 전단결합강도 비교 연구 (A comparison study on shear bond strength of 3D printed resin and conventional heat-cured denture base resin to denture relining materials)

  • 조성윤;송영균
    • 구강회복응용과학지
    • /
    • 제37권4호
    • /
    • pp.232-243
    • /
    • 2021
  • 목적: 다양한 3D 프린팅 의치상 레진과 여러 가지 의치 첨상 재료 간의 전단결합강도를 평가하여 기존의 열중합 의치상 레진과의 전단결합강도를 비교 평가하고자 하였다. 연구 재료 및 방법: 열중합레진(Vertex RS)과 3D프린팅 의치상 레진 두종(DENTCA Denture base II, NextDentTM Base)을 사용하였다. 의치 첨상 재료로는 성분이 다른 총 4종(Tokuyama Rebase II fast, Kooliner, Denture Liner, Denture Liner, Lang Jet Denture Repair Kit)을 사용하여 12개의 군으로 분류하였다. ISO/TS 11405규격에 따라 접착을 시행하였다. 전단결합강도를 측정하였고, 이후 입체현미경과 주사전자현미경을 이용하여 접착 계면을 관찰하고 파절편의 분석을 통하여 파절 양상을 조사하였다. 결과: 3D 프린팅 의치상 레진 군에서 의치 첨상 재료와의 전단결합강도가 열중합레진 군에 비해 유의하게 낮은 전단결합강도 결과를 나타내었다(P < 0.05). Polymethyl methacrylate계열의 첨상재료의 경우, 의치상종류와 관계없이 높은 전단결합강도를 보였다. 파절 양상은 대부분의 군에서 접착성 파절이 나타났고 일부 군에서 응집성 파절과 혼합성 파절 양상이 나타났다. 결론: Polymethyl methacrylate를 주성분으로 하는 의치 첨상 재료가 실험에 사용된 모든 의치상 레진에서 다른 의치 첨상 재료와 비교하여 높은 전단 결합강도 값을 나타내었지만, 직접법으로 의치 첨상을 시행할 경우 단량체로 Isobutyl methacrylate 성분의 의치 첨상재료를 사용하는 것이 전단결합강도면에서 유리할 것으로 사료된다.

인터넷 통신상에서 자바 바이트 코드 수정을 이용한 애플릿 제어 (Applet Control using Java Bytecode Modification on the Internet Communication)

  • 김광준;나상동;배용근
    • 한국정보통신학회논문지
    • /
    • 제7권1호
    • /
    • pp.90-99
    • /
    • 2003
  • 인터넷을 통한 웹 서버로부터 다운로드 받은 자바 애플릿은 클라이언트 브라우저의 가상 머시인에 실행 하였다. 자바 애플릿을 실행하기 전에 자바 가상 머시인은 bytecode 수정자를 이용하여 bytecode 프로그램을 검색하며 해석기를 이용하여 실행시간 테스트를 수행한다. 그러나 이러한 테스트들은 서비스 거부 공격, 이메일 위조 공격, URL 추적 공격 또는 지속적인 사운드 공격과 같은 원하지 않는 실행시간 동작을 예방 할 수는 없다. 본 논문에서는 이러한 애플릿을 보호하기 위해 자바 바이트 코드 수정 기술이 사용되었다. 이러한 기술은 검사를 수행할 적절한 바이트 코드를 삽입함으로서 애플릿의 동작을 제한한다. 자바 바이트 수정은 두 개의 일반적인 형태로 분류되며, 클래스 레벨 수정은 마지막 클래스 아닌 서브클래스를 포함하고 메소드 레벨 수정은 마지막 클래스 또는 인터페이스로부터 객체를 제어할 때 사용된다. 본 논문은 악성 애플릿들이 프록시 서버를 이용한 자바 바이트 코드 수정에 의해 제어되는 것을 나타내고 있으며, 또한 이러한 구현은 웹 서버, JVM, 웹 브라우저상에서 어떠한 변화도 요구하지 않는다.

핫스팟 접근영역 인식에 기반한 바이너리 코드 역전 기법을 사용한 저전력 IoT MCU 코드 메모리 인터페이스 구조 연구 (Low-Power IoT Microcontroller Code Memory Interface using Binary Code Inversion Technique Based on Hot-Spot Access Region Detection)

  • 박대진
    • 대한임베디드공학회논문지
    • /
    • 제11권2호
    • /
    • pp.97-105
    • /
    • 2016
  • Microcontrollers (MCUs) for endpoint smart sensor devices of internet-of-thing (IoT) are being implemented as system-on-chip (SoC) with on-chip instruction flash memory, in which user firmware is embedded. MCUs directly fetch binary code-based instructions through bit-line sense amplifier (S/A) integrated with on-chip flash memory. The S/A compares bit cell current with reference current to identify which data are programmed. The S/A in reading '0' (erased) cell data consumes a large sink current, which is greater than off-current for '1' (programmed) cell data. The main motivation of our approach is to reduce the number of accesses of erased cells by binary code level transformation. This paper proposes a built-in write/read path architecture using binary code inversion method based on hot-spot region detection of instruction code access to reduce sensing current in S/A. From the profiling result of instruction access patterns, hot-spot region of an original compiled binary code is conditionally inverted with the proposed bit-inversion techniques. The de-inversion hardware only consumes small logic current instead of analog sink current in S/A and it is integrated with the conventional S/A to restore original binary instructions. The proposed techniques are applied to the fully-custom designed MCU with ARM Cortex-M0$^{TM}$ using 0.18um Magnachip Flash-embedded CMOS process and the benefits in terms of power consumption reduction are evaluated for Dhrystone$^{TM}$ benchmark. The profiling environment of instruction code executions is implemented by extending commercial ARM KEIL$^{TM}$ MDK (MCU Development Kit) with our custom-designed access analyzer.

위성 시스템 개념설계 소프트웨어 개발 (Development of Satellite Conceptual Design Software)

  • 박우성;윤중섭;유창경;최기영;김희섭
    • 한국항공우주학회지
    • /
    • 제37권9호
    • /
    • pp.923-930
    • /
    • 2009
  • 본 논문에서는 위성의 개념설계와 교육목적에 활용할 수 있는 위성 시스템 개념설계 소프트웨어 개발에 관한 내용을 담고 있다. 이 소프트웨어는 상용도구인 MATLAB, STK, Excel을 이용하여 구성되었다. MATLAB은 기본연산, GUI 구성, 엑셀 데이터베이스 관리 및 STK의 제어를 담당한다. AGI사에서 개발한 궤도 시뮬레이션 소프트웨어인 STK는 위성의 정밀 궤도정보의 산출을 담당한다. 마이크로소프사의 엑셀은 기존 위성들의 데이터 베이스 와 본 개념설계 소프트웨어의 임시적 및 최종 결과의 저장장소로 사용된다. 위성의 개념설계는 위성의 대략적인 전력시스템과 질량계를 추정하는 것이다. 전력시스템 설계과정에서는 태양전지판과 배터리의 크기를 결정한다. 기존 위성들의 데이터베이스를 기반으로 목표 위성의 부시스템의 질량 분할을 추정할 수 있다. 개발된 소프트웨어의 입증을 위해 아리랑 1호 및 2호에 대한 개념설계결과를 포함하였다.