• Title/Summary/Keyword: Inter-calibration

Search Result 211, Processing Time 0.047 seconds

Evaluation of Methodology for the Measurement of VOCs in the Air by Adsorbent Sampling and Thermal Desorption with GC Analysis (흡착포집 및 열탈착/GC 분석에 의한 공기 중 휘발성 유기화합물의 측정방법론 평가)

  • 백성옥;황승만;박상곤;전선주;김병주;허귀석
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.2
    • /
    • pp.121-138
    • /
    • 1999
  • This study was carried out to evaluate the performance of a sampling and analytical methodology for the measurement of selected volatile organic compounds (VOCs) in the ambient air. VOCs were determined by the adsorbent tube sampling and automatic thermal desorption coupled with GC/FID and GC/MSD analysis. Target analytes were aromatic VOCs, including BTEX, 1,3,5-and 1,2,4,-trimethylbenzenes(TMBs), and naphthalene. The methodology was investigatedwith a wide range of performance criteria such as repeatability, linearity, lower detection limits, collection efficiency, thermal conditioning, breakthrough volume and calibration methods using internal and external standards. standards. Stability of samples collected on adsorbent tubes during storage was also investigated. In addition, the sampling and analytical method developed during this study was applied to real samples duplicately collected in various indoor and outdoor environments. Precisions for the duplicate samples and distributed volume samples appeared to be well comparable with the performance criteria recommended by USEPA TO-17. The audit accuracy was estimated by inter-lab comparison of both duplicate samples and standard materials between the two independent labs. The overall precision and accuracy of the method were estimated to be within 30% for major aromatic VOCs such as BTEX. This study demonstrated that the adsorbent sampling and thermal desorption method can be reliably applied for the measurement of BTEX in ppb levels frequently occurred in common indoor and ambient environments.

  • PDF

Simultaneous Determination of Alkoxyalcohols in Wet Wipes Using Static Headspace Gas Chromatography and Mass Spectrometry

  • Lee, Soojin;Pyo, Heesoo;Chung, Bong Chul;Kim, Haidong;Lee, Jeongae
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.11
    • /
    • pp.3280-3288
    • /
    • 2014
  • Alkoxyalcohols are used as solvents or preservatives in various consumer products such as wet wipes. The metabolites of alkoxyalcohols are known to be chronically toxic and carcinogenic to animals. Thus, an analytical method is needed to monitor alkoxyalcohols in wet wipes. The aim of this study was to develop a simultaneous analytical method for 14 alkoxyalcohols using headspace gas chromatography coupled with mass spectrometry to analyze the wet wipes. This method was developed by comparing with various headspace extraction parameters. The linear calibration curves were obtained for the method ($r^2$ > 0.995). The limit of detection of alkoxyalcohols ranged from 2 to $200ng\;mL^{-1}$. The precision of the determinative method was less than 18.20% coefficient of variation both intra and inter days. The accuracy of the method ranged from 82.86% to 119.83%. (2-Methoxymethylethoxy)propanol, 2-phenoxyethanol, and 1-phenoxy-2-propanol were mainly detected in wet wipes.

Determination of Tocopherol Contents in Refined Edible Oils Using an HPLC Method

  • Hu, Jiang-Ning;Zhu, Xue-Mei;Adhikari, Prakash;Li, Dan;Kim, In-Hwan;Lee, Ki-Teak
    • Preventive Nutrition and Food Science
    • /
    • v.14 no.3
    • /
    • pp.260-264
    • /
    • 2009
  • A high-performance liquid chromatography method was applied to determine the contents of tocopherols in edible oils using a LiChrosorb DIOL HPLC column and hexane fortified with 0.1% acetic acid in an isocratic mode. The validation of the method included tests for linearity, sensitivity, accuracy, precision, and recovery. All calibration curves showed good linear regression ($r^2$>0.9995) within the tested ranges. The established method offered good precision and accuracy with overall intra-day and inter-day variations of 0.94$\sim$4.27 and 1.77$\sim$ 4.88%, respectively. The tocopherol recoveries ranged from 91.44$\sim$108.90%. Subsequently, the method was successfully applied to qualitatively and quantitatively determine the total contents of $\alpha$, $\gamma$, and $\delta$-tocopherols in 12 selected refined edible oils, showing a range of 0.92 to 188.71 mg/100 g.

A 0.25-$\mu\textrm{m}$ CMOS 1.6Gbps/pin 4-Level Transceiver Using Stub Series Terminated Logic Interface for High Bandwidth

  • Kim, Jin-Hyun;Kim, Woo-Seop;Kim, Suki
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.165-168
    • /
    • 2002
  • As the demand for higher data-rate chip-to-chip communication such as memory-to-controller, processor-to-processor increases, low cost high-speed serial links\ulcorner become more attractive. This paper describes a 0.25-fm CMOS 1.6Gbps/pin 4-level transceiver using Stub Series Terminated Logic for high Bandwidth. For multi-gigabit/second application, the data rate is limited by Inter-Symbol Interference (ISI) caused by channel low pass effects, process-limited on-chip clock frequency, and serial link distance. The proposed transceiver uses multi-level signaling (4-level Pulse Amplitude Modulation) using push-pull type, double data rate and flash sampling. To reduce Process-Voltage-Temperature Variation and ISI including data dependency skew, the proposed high-speed calibration circuits with voltage swing controller, data linearity controller and slew rate controller maintains desirable output waveform and makes less sensitive output. In order to detect successfully the transmitted 1.6Gbps/pin 4-level data, the receiver is designed as simultaneous type with a kick - back noise-isolated reference voltage line structure and a 3-stage Gate-Isolated sense amplifier. The transceiver, which was fabricated using a 0.25 fm CMOS process, performs data rate of 1.6 ~ 2.0 Gbps/pin with a 400MHB internal clock, Stub Series Terminated Logic ever in 2.25 ~ 2.75V supply voltage. and occupied 500 * 6001m of area.

  • PDF

Simultaneous Determination of Four Bioactive Constituents in Galgeun Tang by HPLC/DAD. (HPLC-DAD를 이용한 갈근탕 중 4종 성분의 동시분석법 확립)

  • Won, Jin-Bae;Jeon, Won-Kyung;Ma, Jin-Yeul;Ma, Choong-Je
    • Korean Journal of Pharmacognosy
    • /
    • v.40 no.3
    • /
    • pp.224-228
    • /
    • 2009
  • For the quality control of traditional herbal medicine, Galgeun tang, simultaneous determination of glycyrrhizin, paeoniflorin, puerarin, 6-gingerol was established by using a high performance liquid chromatographic (HPLC) method with diode array detector. To separate five four constituents, DIONEX $C_{18}$ column ($5{\mu}m$, $120{\AA}$, $4.6\;mm{\times}150\;mm$) was used with gradient elution system of water and methanol. Validation of the chromatography method was evaluated by linearity, recovery, and precision test. Calibration curve of standard components showed excellent linearity ($R^2$>0.9906). Limits of detection (LOD) and limits of quantification (LOQ) varied from 0.15 to $0.52{\mu}g$/ml and 0.27 to $0.80{\mu}mg$/ml, respectively. The relative standard deviations (RSDs) of data of the intra-day and inter-day experiments were less than 2.88% and 1.21%, respectively. The results of recovery test were ranged from 96.71 to 106.29% with RSD values 0.01-0.80%.

A Multi-purpose Fingerprint Readout Circuit Embedding Physiological Signal Detection

  • Eom, Won-Jin;Kim, Sung-Woo;Park, Kyeonghwan;Bien, Franklin;Kim, Jae Joon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.6
    • /
    • pp.793-799
    • /
    • 2016
  • A multi-purpose sensor interface that provides dual-mode operation of fingerprint sensing and physiological signal detection is presented. The dual-mode sensing capability is achieved by utilizing inter-pixel shielding patterns as capacitive amplifier's input electrodes. A prototype readout circuit including a fingerprint panel for feasibility verification was fabricated in a $0.18{\mu}m$ CMOS process. A single-channel readout circuit was implemented and multiplexed to scan two-dimensional fingerprint pixels, where adaptive calibration capability against pixel-capacitance variations was also implemented. Feasibility of the proposed multi-purpose interface was experimentally verified keeping low-power consumption less than 1.9 mW under a 3.3 V supply.

Comparison of Aerosol Optical Properties from Different Models of Skyradiometer (스카이라디오미터 모델에 따른 에어러솔의 광학적 특성 비교)

  • Choi, Yongjoo;Ghim, Young Sung;Sohn, Byung-Ju
    • Atmosphere
    • /
    • v.21 no.3
    • /
    • pp.311-317
    • /
    • 2011
  • Aerosol optical properties from the radiation measurements by SKYNET PREDE skyradiometers, POM-01 and POM-02 were compared during the inter-calibration campaign at Seoul in February 2009. The monochromatic solar flux at the top of the atmosphere ($F_0$) gave a relative standard deviation (RSD) of 9-10% for both instruments. This comparatively high value of RSD was probably because $F_0$ was determined at short time intervals, in the morning and afternoon, using the measurements made in the polluted environment of Seoul. Although POM-02 was more effective in tracking the solar radiation, aerosol optical depths (AODs) from the two instruments were very similar after the cloud screening procedure. The squared correlation coefficients ($R^2$) of single scattering albedo (SSA) and real and imaginary refractive indices between the two instruments was around 0.5 but increased to 0.7-0.8 when only using AOD greater than 0.4. Nevertheless, mean values of the Angstrom exponent, SSA, and the imaginary refractive index of POM-02 were higher than those of POM-01.

Standardization of Eleutherococcus species and HPLC Method Validation for Quantitative Analysis (정량분석을 통한 Eleutherococcus species의 HPLC 분석법 검증과 표준화)

  • Song, Mi-Kyung;Kim, Mi-Yeon;Kim, Ho-Cheol
    • The Korea Journal of Herbology
    • /
    • v.26 no.1
    • /
    • pp.103-110
    • /
    • 2011
  • Objective : For the standardization and quality control of eleutheroside E in Eleutherococcus species, HPLC analysis was performed and eleutherosdie E content was compared in 23 kinds of Eleutherococcus species collected from Korea and China. Methods : The content of eleutheroside E in stem bark of Eleutherococcus species collected from Korea and China were analyzed by HPLC. 0.5% phosphoric acid and acetonitrile was used as mobile solvent. Validation of HPLC analysis method was confirmed by analyzing specificity, linearity, precision and accuracy following ICH guideline. Results : Content of eleutheroside E was determined to be 1.0-1.6% and 0.5-0.8% in Korean and Chinese E. senticosus, respectively. Content of eleutheroside E in E. sessiliflorus was 0.7-1.1% and 0.2-0.4% respectively in Korean and Chinese origin. All calibration curves showed good linear regression. The method showed good precision and accuracy with intra-day and inter-day variations of 0.880-3.442% (RSD) and 0.606-3.328% (RSD), respectively, and average recovery was of 0.141-1.363% (RSD), for the eleutheroside E analyzed. Conclusion : These results might be used to establish a criterion of eleutheroside E in Eleutherococcus species.

Simultaneous Quantitative Analysis of Flavonoids Isolated from the Leaves of Diospyros kaki (감나무 잎으로부터 분리된 플라보노이드의 동시 정량분석)

  • Kim, Ga-Ram;Kim, Eun-Nam;Jeong, Gil-Saeng
    • Korean Journal of Pharmacognosy
    • /
    • v.51 no.2
    • /
    • pp.139-145
    • /
    • 2020
  • The leaves of Diospyros kaki Thunb. were used to treat heart disease and hypotension in traditionally East Asia. The purpose of this study is to simultaneously quantitiative analyze the content of flavonoids in leaves of D. kaki. The isolated flavonoids from the leaves of D. kaki, and the structure of the isolated flavonoids were analyzed based on 1H and 13C NMR spectrum compared to literature data. Simultaneous quantitative analysis of the isolated flavonoids was validated using high performance liquid chromatography (HPLC). Results showed that the calibration curves of the flavonoid compounds were confirmed that they have a large linearity with a correlation coefficient (R2) of 0.99. In the intra-day and inter-day analysis, accuracy and precision of five compounds were measured that accuracy was 94.39 to 114.47% and precision was less than 3.00%. Content analysis showed hyperoside (1.30 ± 0.09%), astragalin (0.81 ± 0.06%), trifoline (1.58 ± 0.07%), quercetin (0.13 ± 0.02%) and kaempferol (1.33 ± 0.25%).

A Data Acquisition System based upon a Single-board Microcomputer (단일보드 마이크로 컴퓨터를 이용한 자료(資料) 수집장치(蒐集裝置))

  • Choi, C.H.
    • Journal of Biosystems Engineering
    • /
    • v.14 no.4
    • /
    • pp.221-228
    • /
    • 1989
  • A data acquisition system was designed to measure the forces on a rolling coulter in three coordinated directions, angular velocity of the coulter and travel speed of a soil bin. The data acquisition system consisted of a dynamometer, speed transducers, a signal conditioner, an inter-face board, an Aim-65 microcomputer and a digital data recorder. Strain gages were attached on the surface of the dynamometer and connected to form three Wheatstone bridges, which measure the draft force, the vertical force and the side force on the coulter. An interaction among three dimensional forces was found during the calibration. A matrix procedure was used to correct the forces for this interaction. Rotary shaft encoders were mounted on the coulter and on the soil bin drive to measure the angular velocity of the coulter and the travel speed of the soil bin. The angular velocity and the travel speed were computed by counting the number of pulse signals from the rotary shaft encoders every 0.2 second. The digital signals from the rotary shaft encoders were connected to counters and the analog signals from the dynamometer, after passing through the signal conditioner, were connected to the A/D converter. The microcomputer programs, written in assembly language, were developed to read signals from the transducers, convert them to actual unit, display them upon request and record them on a sigital tape every 0.2 second.

  • PDF