• Title/Summary/Keyword: Inter-calibration

Search Result 212, Processing Time 0.024 seconds

Simultaneous Determination of Liquiritin, Nodakenin, Hesperidin and Glycyrrhizin in Bojungikgi-tang Using HPLC-PDA (HPLC-PDA를 이용한 보중익기탕 중 Liquiritin, Nodakenin, Hesperidin 및 Glycyrrhizin의 동시분석)

  • Seo, Chang-Seob;Kim, Jung-Hoon;Shin, Hyeun-Kyoo
    • YAKHAK HOEJI
    • /
    • v.57 no.3
    • /
    • pp.187-193
    • /
    • 2013
  • Bojungikgi-tang has been widely used for enhancement of physical fitness in Korea. The convenient, simple, and accurate high-performance liquid chromatography (HPLC) method was established for simultaneous determination of four marker compounds, liquiritin, nodakenin, hesperidin, and glycyrrhizin in Bojungikgi-tang (Buzhongyiqi-tang in Chinese, Hochuekkito in Japanese), a traditional Korean herbal prescription. The column for optimizing HPLC separation was used a Gemini $C_{18}$ column at column oven temperature of $40^{\circ}C$ with 1.0% (v/v) aqueous acetic acid (A) and 1.0% (v/v) acetic acid in acetonitirle (B) by gradient flow. The flow rate was 1.0 ml/min and the detector was a photodiode array (PDA) set at 254 nm, 280 nm, and 335 nm. Calibration curves of four components were acquired with $r^2$ values ${\geq}0.9999$. The recoveries were found to range 92.11~105.68% with relative standard deviations (RSDs, %) value less than 2.50%. The RSD values of intraand inter-day precision were 0.07~2.50% and 0.16~1.99%, respectively. The contents of liquiritin, nodakenin, hesperidin and glycyrrhizin in Bojungikgi-tang were 3.85~3.92 mg/g, 2.27~2.32 mg/g, 4.14~4.19 mg/g, and 3.39~3.45 mg/g, respectively. The established simultaneous analysis method will be effective for quality control of Bojungikgi-tang.

Adaptive illumination change compensation method for multi-view video coding (다시점 비디오 부호화를 위한 적응적인 조명변화 보상 방법)

  • Hur, Jae-Ho;Cho, Suk-Hee;Hur, Nam-Ho;Kim, Jin-Woong;Lee, Yung-Lyul
    • Journal of Broadcast Engineering
    • /
    • v.11 no.4 s.33
    • /
    • pp.407-419
    • /
    • 2006
  • In this paper, an adaptive illumination change compensation method is proposed for multi-view video coding. In multi-view video, an illumination change can occur due to physically imperfect camera calibration, each different camera position and direction, and so on. These characteristics can cause a performance decrease in the multi-view video coding that uses an inter-view prediction by referring to the pictures obtained from the neighboring views. By using the proposed method, a compression ratio of the proposed method in the multi-view video coding is increased, and finally $0.1{\sim}0.6dB$ PSNR(Peak Signal-to-Noise Ratio) improvement was obtained compared with the case of not using the proposed method.

Evaluation on Extraction Conditions and HPLC Analysis Method for Ginsenosides in Panax ginseng (인삼의 추출조건 및 진세노사이드의 HPLC 분석법 평가)

  • Lee, Kyeong Hee;Lee, Dae Young;Lee, Seung Eun;Nam, Ki Yeul;Hwang, Gwang Bo;Kim, Hyung Don;Lee, Jae Won;Choi, Je Hun;Ahn, Young Sup;Kim, Seung Yu;Kim, Geum Soog
    • Korean Journal of Medicinal Crop Science
    • /
    • v.24 no.1
    • /
    • pp.47-54
    • /
    • 2016
  • Background : A new extraction method-heated ultrasonic extraction was qualitatively and quantitatively analyzed for the extraction of major ginsenosides from ginseng extract; this new high-performance liquid chromatography (HPLC) method was compared with the official extraction method of Korean industrial standards and standard for health functional food. Methods and Results : Ginsenoside compounds were analyzed for 35 minutes by the new HPLC analysis method using a Halo$^{(R)}$ RP-Amide column. The new HPLC analysis method was validated by the measurement of intra-day and inter-day precision, accuracy, limit of detection (LOD), and limit of quantification (LOQ) of each ginsenoside. The correlation coefficients (r2) for the calibration curves of the ginsenoside compounds were over 0.9997 in terms of linearity. The heated ultrasonic extraction method using ultrasonication for 30 minutes at $50^{\circ}C$ yielded higher amount of ginsenosides than the extraction method of the Korean industrial standards owing to the enhancement of extraction efficiency. Conclusions : Compared to the other extraction methods, the heated ultrasonic extraction method yielded a higher amount of ginsenoside Rb1 than Rg1 index compounds for the quality evaluation of ginseng roots.

Quality Evaluation of Modified Bo-Yang-Hwan-O-Tang by Capillary Electrophoresis and High-performance Liquid Chromatography

  • Chen, Jianbo;Wu, Enqi;Zhu, Hongmei;Lee, Kwan-Jun;Chu, Van Men;Cho, Cheong-Weon;Kim, Young-Ho;Park, Yong-Ki;Lee, Won-Jae;Kang, Jong-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.8
    • /
    • pp.2666-2670
    • /
    • 2011
  • High-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) were used to identify five active components in the modified herbal decoction Bo-Yang-Hwan-O-Tang (mBHT), i.e., amygdalin, decursin, paeoniflorin, salvianolic acid B, and calycosin-7-O-${\beta}$-D-glycoside. These components were identified by comparing their retention times and mass spectra with those of reference compounds. The conditions of both analytical methods were optimized and validated. Sufficient separation of target analytes was achieved using a buffer consisting of 40 mM sodium borate and 60 mM sodium dodecylsulfate (SDS) containing 10% methanol (pH 9.5) at 250 nm for CE analysis and gradient elution with a water-methanol mobile phase and ultraviolet (UV) photodiode array detector (DAD) at 250 nm for HPLC analysis. The mBHT components were determined within 65 min by HPLC and 16 min by CE. All calibration curves showed high linearity (R > 0.999) within the ranges tested. Intra-day and inter-day precision were less than 1.6% and 1.8% for HPLC and 2.5% and 4.8% for CE, respectively. The accuracy of the methods ranged from 98.8% to 102.3% for HPLC and from 95.9% to 108.2% for CE.

Simultaneous Analysis of Six Compounds in Yijin-tang by HPLC-PDA (HPLC-PDA을 이용한 이진탕 중 6종 성분의 동시분석)

  • Kim, Seong-Sil;Kim, Jung-Hoon;Shin, Hyeun-Kyoo;Seo, Chang-Seob
    • Herbal Formula Science
    • /
    • v.21 no.1
    • /
    • pp.71-79
    • /
    • 2013
  • Objectives : Yijin-tang has been used in the treatment of gastrointestinal diseases such as irritable bowel syndrome, gastritis, and gastric ulcer. In this study, a high-performance liquid chromatography (HPLC) method was established for simultaneous analysis of six compounds, liquiritin, glycyrrhizin, hesperidin, 6-gingerol, homogentisic acid, and 3,4-dihydroxybenzaldehyde in Yijin-tang, a traditional Korean herbal medicinal preparation. Methods : A Gemini C18 column was used for the separation of six constituents at $40^{\circ}C$. The mobile phase using gradient elution consist of two solvent systems, 1.0% acetic acid in water (A) and 1.0% acetic acid in acetonitrile (B). The flow-rate was 1.0 mL/min and injection volume was $10{\mu}g$. The detector was a photodiode array (PDA) detector set at 254 nm and 280 nm. Results : The calibration curves of six compounds showed good linearity in various concentration ranges ($R^2{\geq}0.9997$). The limits of detection (LOD) and limits of quantification (LOQ) were 0.028-$0.192{\mu}g/mL$ and 0.093-$0.540{\mu}g/mL$, respectively. The RSD (%) of the intra and inter day validations were 0.03-0.84% and 0.05 -1.00%, respectively. Recovery was 96.14-01.90% and RSD (%) was less than 1.5%. Conclusions : The established simultaneous analysis methods will help management to improve the quality of Yijin-tang.

Evaluation of the Immune-Stimulating Activity of Samul-tang, a Traditional Korean Herbal Medicine, Standardized by HPLC-PDA

  • Seo, Chang-Seob;Ha, Hye-Kyung;Jung, Da-Young;Lee, Ho-Young;Shin, Hyeun-Kyoo
    • The Journal of Korean Medicine
    • /
    • v.32 no.3
    • /
    • pp.25-34
    • /
    • 2011
  • Objectives: We performed simultaneous determination of five constituents by HPLC in Samul-tang (SMT). Additionally, we investigated the immune-stimulatory potential of SMT on specific cellular and humoral immune responses in ovalbumin (OVA)-immunized mice. Methods: Reverse-phase chromatography using a Gemini C18 column operating at $40^{\circ}C$, and photodiode array (PDA) detection at 190-400 nm, were used for quantification of the five components of SMT. Mobile phase using a gradient flow consisted of two solvent systems. Solvent A was 1.0% (v/v) aqueous acetic acid and solvent B was acetonitrile with 1.0% (v/v) acetic acid. C57BL/6 mice were immunized intraperitoneally with OVA/alum ($100{\mu}g/200{\mu}g$) on days 1, 8, and 15. The extract of SMT (1000 mg/kg) was given to mice orally for 21 days (from day 1 to day 21). At day 22, OVA-, lipopolysaccharide (LPS)- and concanavalin A (Con A)-stimulated splenocyte proliferation and OVA-specific and total antibodies were measured in plasma. Results: Calibration curves were acquired with $r^2$>0.9999, and the relative standard deviation (RSD, %) for intra- and inter-day precision were both less than 3.5%. The recovery was in the range of 95.69-115.12%, with an RSD less than 6.0%. The contents of five components in SMT were 1.08-15.30 mg/g. SMT significantly enhanced Con A-induced splenocyte proliferation in OVA-immunized mice (p<0.01). Also, SMT significantly enhanced OVAspecific IgG, IgG1 and total IgM levels in plasma compared with the OVA-immunized group. Conclusions: The established method will be applied for the quantification of major components and immunestimulating activity in OVA-immunized mouse model of SMT.

Determination of Dibutyltin in Sediments Using Isotope Dilution Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry

  • Yim, Yong-Hyeon;Park, Ji-Youn;Han, Myung-Sub;Park, Mi-Kyung;Kim, Byung-Joo;Lim, Young-Ran;Hwang, Eui-Jin;So, Hun-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.3
    • /
    • pp.440-446
    • /
    • 2005
  • A method is described for the determination of dibutyltin (DBT) in sediment by isotope dilution using liquid chromatography inductively-coupled plasma/mass spectrometry (LC-ICP/MS). To achieve the highest accuracy and precision, special attentions are paid in optimization and evaluation of overall processes of the analysis including extraction of analytes, characterization of the standards used for calibration and LC-ICP/MS conditions. An approach for characterization of natural abundance DBT standard has been developed by combining inductively-coupled plasma/optical emission spectrometry (ICP/OES) and LC-ICP/MS for the total Sn assay and the analysis of Sn species present as impurities, respectively. An excellent LC condition for separation of organotin species was found, which is suitable for simultaneous DBT and tributyltin (TBT) analysis as well as impurity analysis of DBT standards. Microwave extraction condition was also optimized for high efficiency while preventing species transformation. The present method determines the amount contents of DBT in sediments with expanded uncertainty of less than 5% and its result shows high degree of equivalence with reference values of an international inter-comparison and a certified reference material (CRM) within stated uncertainties.

Simultaneous Quantification of Urinary L-, and D-Lactate by Reversed-Phase Liquid Chromatography Tandem Mass Spectrometry (액체크로마토그래프-탠덤질량분석기(LC-MS/MS)를 이용한 소변 내 D-, L- Lactate 분리 및 정량)

  • Moon, Chul Jin;Yang, Song Hyun
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.15 no.2
    • /
    • pp.59-64
    • /
    • 2015
  • Purpose: Lactate has two optical isomers, L-lactate and D-lactate. In human L-lactate is the most abundant enantiomer of lactate. As plasma and urinary levels of L-lactate is associated with inherited metabolic disorders in general, D-lactate have been linked to the presence of diabetes and inflammatory bowel disease. Previously developed techniques have shown several limitations to further evaluate D-lactate as a biomarker for this condition. In this paper, we describe a highly sensitive, specific and fast liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the analysis of D-, L-lactate in urine. Methods: D- and L-lactate were quantified using high performance liquid chromatography tandem mass spectrometry (LC-MS/MS) with labelled internal standard. Samples were derivatized with (+)-O,O'-diacety-L-tartaric anhydride (DATAN) and seperated on a Poroshell 120 EC-C18 column. Results: Quantitative analysis of D-, and L-lactate was achieved successfully. Calibration curves were linear (r>0.999) over $0.5-100{\mu}g/mL$. Stabilities for samples were within the 10% varation. Inter- and Intra-day assay variations were below 10%. Conclusion: The presented method proved to be suitable for the quantitation of D- and L-lactate and opens the possibility to explore the use of D-lactate as a biomarker.

Simultaneous Analysis of Six Constituents in Oyaksungi-san using HPLC-PDA (HPLC-PDA를 이용한 오약순기산 중 6종 성분의 동시분석)

  • Seo, Chang-Seob;Kim, Jung-Hoon;Shin, Hyeun-Kyoo
    • Herbal Formula Science
    • /
    • v.20 no.2
    • /
    • pp.37-46
    • /
    • 2012
  • Objectives : Oyaksungi-san(Wuyaoshunqisan) has been used for treatment of stroke and rheumatoid arthritis in Korea. In this study, a simple and accurate high-performance liquid chromatography(HPLC) method was established for simultaneous determination of six main components, liquiritin, ferulic acid, naringin, hesperidin, neohesperidin, and glycyrrhizin in Oyaksungi-san, a traditional Korean herbal prescription. Methods : The analytical column for separation of six constituents was used a Gemini $C_{18}$ column maintained at $40^{\circ}C$. The mobile phase consisted of two solvent systems, 1.0% (v/v) acetic acid in $H_2O$ (A) and 1.0% (v/v) acetic acid in acetonitrile (B) by gradient flow. The flow rate was 1.0 mL/min and the detector was a photodiode array (PDA) set at 254 nm for glycyrrhizin, 280 nm for liquiritin, naringin, hesperidin, and neohesperidin, and 320 nm for ferulic acid. Results : Calibration curves were acquired with $r^2$ values ${\geq}0.9998$. The results of recovery test were 91.58%-105.90% with a relative standard deviations (RSDs, %) value less than 2.0%. The values of RSD for intra- and inter-day precision were 0.03%-1.72% and 0.03%-1.63%, respectively. The contents of the six compounds in Oyaksungi-san were 0.33-9.30 mg/g. Conclusions : The newly established HPLC method will be helpful to improve quality control of Oyaksungi-san.

Development of Quality Control Method for a Novel Herbal Medicine, HPL-1 using UHPLC (UHPLC를 이용한 새로운 한약제제 HPL-1의 품질관리법 개발)

  • Kim, Se-Gun;Lamichhane, Ramakanta;Lee, Kyung-Hee;Jung, Hyun-Ju
    • The Korea Journal of Herbology
    • /
    • v.30 no.3
    • /
    • pp.19-24
    • /
    • 2015
  • Objectives : HPL-1, a novel herbal medicine which is composed of five herbs such as Kalopanacis Cortex, Chaenomelis Fructus, Raphani Semen, Atractylodis Rhizoma and Pulvis Aconiti Tuberis Purificatum, was developed for treatment of osteoarthritis. This study is aimed to develop analytical method for consistent quality control of HPL-1 and validate chromatographic method. Methods : Chromatographic analysis was performed using ultra-high performance liquid chromatography - diode array detector (UHPLC-DAD) equipped with RP-amide column, column oven, and auto sampler. Marker compounds [protocatechuic acid, chlorogenic acid, liriodendrin, 3,5-dicaffeoylquinic acid, ${\beta}$-D-(3-O-sinapoyl)-fructofuranosyl-$\alpha$-D-(6-O-sinapoyl)glucopyranoside and benzoylmesaconine] were separated by step gradient elution of acetonitrile and 0.1% phosphoric acid/water. The method validation was evaluated by quantitative validation parameters of linearity, accuracy, precision, limit of detection (LOD) and limit of quantification (LOQ) according to KFDA guideline.Results : An optimized method for six marker compounds in HPL-1 was established by UHPLC-DAD. The correlation coefficient (R2) with each calibration curve was greater than 0.99. The LOD and LOQ were within the range of 0.008-0.090 and $0.023-0.274{\mu}g/mL$, respectively. The relative standard deviation (RSD) of intra- and inter-day variability were less than 4.0%. The result of recovery test was range from 93.3-106.3% with RSD < 4.0%.Conclusions : These results suggest that the quantitative UHPLC method is precise, accurate, effective for quality evaluation of HPL-1. The method may also contribute to improve quality of crude drug preparations used for treatment of various diseases.