Browse > Article
http://dx.doi.org/10.5012/bkcs.2011.32.8.2666

Quality Evaluation of Modified Bo-Yang-Hwan-O-Tang by Capillary Electrophoresis and High-performance Liquid Chromatography  

Chen, Jianbo (College of Pharmacy, Chungnam National University)
Wu, Enqi (College of Pharmacy, Chungnam National University)
Zhu, Hongmei (College of Pharmacy, Chungnam National University)
Lee, Kwan-Jun (College of Pharmacy, Chungnam National University)
Chu, Van Men (College of Pharmacy, Chungnam National University)
Cho, Cheong-Weon (College of Pharmacy, Chungnam National University)
Kim, Young-Ho (College of Pharmacy, Chungnam National University)
Park, Yong-Ki (Oriental medicine R&D center, Dongguk University)
Lee, Won-Jae (College of Pharmacy, Chosun University)
Kang, Jong-Seong (College of Pharmacy, Chungnam National University)
Publication Information
Abstract
High-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) were used to identify five active components in the modified herbal decoction Bo-Yang-Hwan-O-Tang (mBHT), i.e., amygdalin, decursin, paeoniflorin, salvianolic acid B, and calycosin-7-O-${\beta}$-D-glycoside. These components were identified by comparing their retention times and mass spectra with those of reference compounds. The conditions of both analytical methods were optimized and validated. Sufficient separation of target analytes was achieved using a buffer consisting of 40 mM sodium borate and 60 mM sodium dodecylsulfate (SDS) containing 10% methanol (pH 9.5) at 250 nm for CE analysis and gradient elution with a water-methanol mobile phase and ultraviolet (UV) photodiode array detector (DAD) at 250 nm for HPLC analysis. The mBHT components were determined within 65 min by HPLC and 16 min by CE. All calibration curves showed high linearity (R > 0.999) within the ranges tested. Intra-day and inter-day precision were less than 1.6% and 1.8% for HPLC and 2.5% and 4.8% for CE, respectively. The accuracy of the methods ranged from 98.8% to 102.3% for HPLC and from 95.9% to 108.2% for CE.
Keywords
Quality control; Modified Bo-Yang-Hwan-O-Tang; High-performance liquid chromatography; Capillary electrophoresis; Marker component;
Citations & Related Records

Times Cited By Web Of Science : 0  (Related Records In Web of Science)
Times Cited By SCOPUS : 0
연도 인용수 순위
  • Reference
1 Kim, E. H.; Kim, J.; Son, Y. O.; Chung, G. H.; Jang, Y. S. Immunopharmacol. Immunotoxicol. 2002, 24, 423.   DOI   ScienceOn
2 Lee, J. C.; Jun, H. N.; Kim, J.; Woo, W. H.; Jeong, W. Y.; Chung, G. H.; Jang, Y. S. Int. J. Clin. Chem. 2003, 329, 133.   DOI   ScienceOn
3 Jiang, W. Y. Trends Pharmacol. Sci. 2005, 26, 558.   DOI   ScienceOn
4 Normile, D. Science 2003, 299, 188.   DOI   ScienceOn
5 Wang, Z. G.; Ren, J. Trends Pharmacol. Sci. 2002, 23, 347.   DOI   ScienceOn
6 Malik, I. A.; Gopalan, S. Eur. J. Epidemiol. 2003, 18, 817.
7 Shekelle, P. G.; Morton, S. C.; Suttorp M. J.; Buscemi, N.; Friesen, C. Ann. Intern. Med. 2005, 142, 1042.   DOI
8 Liang, Y. Z.; Xie, P. S.; Chan, J. J. Chromatogr. B 2004, 812, 53.   DOI   ScienceOn
9 Xie, P. S. People's Medical Publishing House 2005, 18.
10 Chen, L. L.; Qi, J.; Chang, Y. X.; Zhu, D. N.; Yu, B. Y. J. Pharm. Biomed. Anal. 2009, 50, 127.   DOI   ScienceOn
11 Chen, L.; Wang, D. W.; Wu, J.; Yu, B. Y.; Zhu, D. N. J. Pharm. Biomed. Anal. 2009, 49, 267.   DOI   ScienceOn
12 Yi, S. N.; Tao, G.; Yin, S.; Li, F. M. J. Chromatogr. B 2003, 792, 147.   DOI   ScienceOn
13 Marchart, E.; Kopp, B. J. Chromatogr. B 2003, 792, 363.   DOI   ScienceOn
14 Gu, M.; Zhang, S. F.; Su, Z. G.; Chen, Y.; Fan, O. Y. J. Chromatogr. A 2004, 1057, 13.   DOI   ScienceOn
15 Sun, Y.; Guo, T.; Sui, Y.; Li, F. J. Chromatogr. B 2003, 792, 147.   DOI   ScienceOn
16 Egeberg, P. K.; Bergli, S. O. J. Chromatogr. A 2002, 950, 221.   DOI   ScienceOn