• Title/Summary/Keyword: Integrated module

Search Result 987, Processing Time 0.028 seconds

A Study of the DEVOPS Test Automation Module for Integrated Development Environment (통합 개발환경에서 데브옵스 기반 테스트 자동화 모듈 개발에 대한 연구)

  • Jung Kwang Lak;Kim Sun Joo
    • Convergence Security Journal
    • /
    • v.22 no.1
    • /
    • pp.3-9
    • /
    • 2022
  • The role of the integrated development environment is very important in software development of a development project. After many developers develop different modules, software product is completed through compile, debugging, integration, testing, and distribution. However, bugs and various issues in the development process cause problems such as quality deterioration of software product and dissatisfaction with requirements. So the need for automated testing to avoid these problems and improve quality has increased. In this study, we propose test automation modules of four perspectives to improve quality throughout the test automation in an integrated development environment. Each automation module operates through the tool chain of an integrated build framework implemented on the devops.

Mobile-based Universal Integrated Control Module for an Efficient Vehicle Control System (효율적인 차량제어를 위한 모바일기반의 범용 통합 제어모듈)

  • Hwang, Jae-Young;Lee, Ju-Han;Lee, Ho-Jin;Chung, Yeon-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.9
    • /
    • pp.1993-1998
    • /
    • 2010
  • This paper presents an integrated control module for controlling transportation machine and automatic navigation using a combined technology of mobile telematics and transportation machine telematics, i.e. Mobile In Vehicle (MIV). This development includes hardware implementation and its verification of control mechanism applied to vehicle. In particular, the module is designed to be versatile in such a way that it can collect various information and facilitate various options for convenience by supporting existing networks, such as TCP/IP, Wi-Fi and 3G mobile radio networks. The study offers its versatility, intelligence and cost-effectiveness by enabling the module to support network-independent service, whereas conventional modules operate only in a certain network. Based on this module, a multiple of subsequent convenient functions for transportation machine can further be developed for safe and intelligent transportation machines.

Analysis on Thermal Performance of BIPV in Spandrel (스펜드럴부 적용 BIPV 모듈의 열 특성 분석)

  • Kim, Ha-Ryeon;Kim, Jin-Hee;Kang, Gi-Hwan;Yu, Gwon-Jong;Kim, Jun-Tae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.364-369
    • /
    • 2011
  • Recently, the cases of BIPV(Building-integrated Photovoltaic) have been increased with interest in renewable energy application for buildings. PV System in building can perform a variety of roles as an energy supplier, exterior materials, aesthetic element and etc. To apply PV modules in buildings, various factors should be considered, such as the installation angle and orientation of PV module, shading, and temperature. The temperature of PV modules that are attached to building surfaces especially is one of the most important factors, as it affects both the electrical efficiency of a PV module and the energy load in a building. BIPV modules designed as finished material for spandrels are presented in this paper. The purpose of this study is to analysis on the thermal performance characteristics of BIPV modules. This study dealt with different types of BIPV modules depending on the backside material, such as clear glass and backsheet. The analysis of monitoring data shows that the PV module temperature was closely related to the solar radiation on the BIPV module surface, and the BIPV used at the backside also had an effect on the PV module temperature that in turn determines its thermal performance.

  • PDF

Design and Fabrication of a Ka-Band 10 W Power Amplifier Module (Ka-대역 10 W 전력증폭기 모듈의 설계 및 제작)

  • Kim, Kyeong-Hak;Park, Mi-Ra;Kim, Dong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.3
    • /
    • pp.264-272
    • /
    • 2009
  • In this paper, a Ka-band 10 W power amplifier module is designed and fabricated using MIC(Microwave Integrated Circuit) module technology which combines multiple power MMIC(Monolithic Microwave Integrated Circuit) chips on a thin film substrate. Modified Wilkinson power dividers/combiners are used for millimeter wave modules and CBFGC-PW-Microstrip transitions are utilized for reducing connection loss and suppressing resonance in the high-gain and high-power modules. The power amplifier module consists of seven MMIC chips and operates in a pulsed mode. for the pulsed mode operation, a gate pulse control circuit supplying the control voltage pulses to MMIC chips is designed and applied. The fabricated power amplifier module shows a power gain of about 58 dB and a saturated output power of 39.6 dBm at a center frequency of the interested frequency band.

A New Photovoltaic System Architecture of Module-Integrated Converter with a Single-sourced Asymmetric Multilevel Inverter Using a Cost-effective Single-ended Pre-regulator

  • Manoharan, Mohana Sundar;Ahmed, Ashraf;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.222-231
    • /
    • 2017
  • In this paper, a new architecture for a cost-effective power conditioning systems (PCS) using a single-sourced asymmetric cascaded H-bridge multilevel inverter (MLI) for photovoltaic (PV) applications is proposed. The asymmetric MLI topology has a reduced number of parts compared to the symmetrical type for the same number of voltage level. However, the modulation index threshold related to the drop in the number of levels of the inverter output is higher than that of the symmetrical MLI. This problem results in a modulation index limitation which is relatively higher than that of the symmetrical MLI. Hence, an extra voltage pre-regulator becomes a necessary component in the PCS under a wide operating bias variation. In addition to pre-stage voltage regulation for the constant MLI dc-links, another auxiliary pre-regulator should provide isolation and voltage balance among the multiple H-bridge cells in the asymmetrical MLI as well as the symmetrical ones. The proposed PCS uses a single-ended DC-DC converter topology with a coupled inductor and charge-pump circuit to satisfy all of the aforementioned requirements. Since the proposed integrated-type voltage pre-regulator circuit uses only a single MOSFET switch and a single magnetic component, the size and cost of the PCS is an optimal trade-off. In addition, the voltage balance between the separate H-bridge cells is automatically maintained by the number of turns in the coupled inductor transformer regardless of the duty cycle, which eliminates the need for an extra voltage regulator for the auxiliary H-bridge in MLIs. The voltage balance is also maintained under the discontinuous conduction mode (DCM). Thus, the PCS is also operational during light load conditions. The proposed architecture can apply the module-integrated converter (MIC) concept to perform distributed MPPT. The proposed architecture is analyzed and verified for a 7-level asymmetric MLI, using simulation results and a hardware implementation.

Integrated Management System of Seismic Observatory Information based on XML (지진 관측소 정보의 XML기반 통합 관리시스템)

  • Lim, Jin-Seub;Jung, Soon-Key
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.8
    • /
    • pp.117-125
    • /
    • 2009
  • In this paper, an integrated management system of seismic observatory information based on XML is proposed. The number of organizations which have their own seismic stations eg. KMA, KIGAM etc is increasing since 1998. Related informations such as location, installed instruments. and operational profile are essential for efficient utilization of seismic data. It's not easy to provide the uniform type of information and has limitation to announce the updated information of station rapidly through individual information management system of each organization. In this paper, we propose an integrated management system of seismic observatory information which can support to manage information of their own seismic observatory by a person in charge via Web, to integrate that in nation-wide and to provide that for users. We investigated minimum information of observatory were needed to use seismic data and the analysis result was structured by using XML. The integrated management system consists of the observatory management module. information search module, and the latest information supply module etc. By using proposed system, seismic observatory information of each organization can be managed and be supplied efficiently in nation-wide.

Roof-attached Crystalline Silicon Photovoltaic Module's Thermal Characteristics (지붕 설치형 결정질 실리콘 태양전지모듈의 온도 특성)

  • Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong;Yoon, Soon-Gil
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.11-18
    • /
    • 2012
  • To expect accurately the maximum power of solar cell module under various installation conditions, it is required to know the performance characteristics like temperature dependence. Today, the PV (photovoltaic) market in Korea has been growing. Also BIPV (building integrated photovoltaic) systems are diversified and become popular. But thermal dependence of PV module is little known to customers and system installers. In IEC 61215,a regulation for testing the crystalline silicon solar cell module, the testing method is specified for modules. However there is limitation for testing the module with diverse application examples. In extreme installation method, there is no air flow between rear side of module and ambient, and it can induce temperature increase. In this paper, we studied the roof type installation of PV module on the surface of one-axis tracker system. We measured temperature on every component of PV module and compared to open-rack structure. As a result, we provide the foundation that explains temperature characteristics and NOCT (nominal operation cell temperature) difference. The detail description will be specified as the following paper.

Transient Characteristics of a Two-Phase Thermosyphon Loop for Multichip Module

  • Nam, Sang-Sig;Choi, Sung-Bong;Kim, Jae-Hee;Kwak, Ho-Young
    • ETRI Journal
    • /
    • v.20 no.3
    • /
    • pp.284-300
    • /
    • 1998
  • A new thermosyphon cooling module (TSCM) has designed, fabricated and tested to cool the multi-chip module consists of a cold plate and an integrated condenser. With an allowable temperature rise of $56^{\circ}C$ on the surface of the heater, the cooling module TSCM can handle a heat flux of about 2.7 $W/cm^2$ using R11 as working fluid. The transient characteristics of the cooling module have been proved to be excellent: that is, when a heat load is applied inside of the system, steady state can be achieved within 10 to 15 minutes. It has been found that the length of the vapor channel between the cold plate and the condenser in addition to the ambient and the condenser temperatures affect the system performance.

  • PDF

Effect of Chip Spacing in a Multichip Module on the Heat Transfer for Paraffin Slurry Flow

  • Choi, Min-Goo;Cho, Keum-Nam
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.9
    • /
    • pp.997-1004
    • /
    • 2000
  • The experiments were conducted by using water and paraffin slurry to investigate the effect of a chip spacing in the multichip module on the cooling characteristics from an in-line $4{\times}3$ array of discrete heat sources which were flush mounted on the top wall of a channel. The experimental parameters were chip spacing in a multichip module, heat flux of simulated VLSI chip, mass fraction of paraffin slurry, and channel Reynolds number. The removable heat flux at the same chip surface temperature decreased as the chip spacing decreased at the first and fourth rows. The local heat transfer coefficients for the paraffin slurry were larger than those for water, and the chip spacing on the local heat transfer coefficients for paraffin slurry influenced less than that for water. The enhancement factor for paraffin slurry showed the largest value at a mass fraction of 5% regardless of the chip spacing, and the enhancement factors increased as the chip spacing decreased. This means that the paraffin slurry is more effective than water for cooling of the highly integrated multichip module.

  • PDF