• Title/Summary/Keyword: Insulation Diagnosis test

Search Result 70, Processing Time 0.025 seconds

Study on Diagnosis for Transformers by Tan $\delta$ and Moisture of Insulation Oil According to Thermal Aging (절연유의 열열화에 따른 Tan $\delta$와 수분의 변화에 의한 변압기의 예방진단 연구)

  • HwangBo, Seung;Han, Min-Koo;Kwak, Hee-Ro;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.241-245
    • /
    • 1988
  • This paper reports the experiments regarding to diagnosis techniques for power transformers by measuring dissipation factor and moisture contents of mineral oils. Thermal aging environments of mineral oils were varied by the specially designed systems. Thermal aging of elevated temperature of $90^{\circ}C$ was performed for about 240 and 460 hours, respectively. Dissipation factor, permittivity, and water content were measured. Our test samples were not exposed to air. Dissipation factor increased while permittivity did not change. The level of dissipation factor determining the insulating quality of mineral oil was compared with the previous results of resistivity and several correction factor.

  • PDF

The Fault Diagnosis of a Transformer Using Neural Network and Transfer Function

  • Park, Byung-Koo;Kim, Jong-Wook;Kim, Sang-Woo;Park, Poo-Gyeon;Park, Tae-Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.127.2-127
    • /
    • 2001
  • A transformer is one of the most important elements in the power network. Transformer faults could cause costly repairs and be dangerous to personnel. To avoid this, its reliable operation has great significance and, therefore, the diagnosis system of the transformer is necessitated. The dissolved gas-in-oil analysis (DGA) is the worldwide popular method of detecting faults such as a hot spot or partial discharges inside the transformer. DGA, however, is not a reliable technique to identify aging phenomena and mechanical faults including insulation failure, inter-turn short, etc. To overcome the drawbacks of DGA, the transfer function method is used to identify effectively these kinds of the mechanical faults. The transformer has a unique transfer function independent of the shape of the input waveform, which can be evaluated through sweep test. This transfer function changes by winding ...

  • PDF

The first report of a study for Field Diagnosis of Large High Voltage Motors (대용량 고압전동기 현장진단연구(I))

  • Park, D.K.;Song, Y.C.;Kim, J.H.;Ryoo, H.S.;Sun, J.H.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1731-1733
    • /
    • 1998
  • This report is the first intermediate report of a series of field test result of large high voltage motors. Major specimens were 3.3/6.6kV class pump motor that was installed and operated for public water service by KOWACO(KOrea WAter resources COperation). The capacity of specimen motors were in range of several hundred kVA. Until now, we get the 22 field test result by testing technique discribed in IEEE standards and discharge-map technique reported by Japanese engineers. The test result were varied very wide range, and there was a tendency according to insulation material and manufacture.

  • PDF

Fundamental Study on the Maintenance Technology for SF6 Gas Condition using Pressure and UHF Sensors (UHF 및 가스센서를 이용한 SF6 가스 상태 감시기술 기초연구)

  • Ahn, Hee-Sung;Cho, Sung-Chul;Eom, Ju-Hong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.20-27
    • /
    • 2007
  • [ $SF_6$ ] gas for compacted power facilities has a important role as an insulation gas. It is very blown well that $SF_6$ gas has the superior characteristics as an insulation gas. For reliable operation of SF6-gas-based high and medium voltage equipment it is very important to keep the insulation ability within a safe range. And the experimental and measuring system were implemented. The test chamber designed to endure up to 3 atmospheric pressure. The analysis results of the experimental data shows that positive partial discharge can be detected by discharge current and UHF signal. Additionally it is shown the possibility that $CO_2$ gas sensor of semiconductor type can be detect the variation of $SF_6$ gas condition. The UHF sensor shows good feature to detect the variation of $SF_6$ gas condition for partial discharge and breakdown discharge.

Partial Discharge Measuring System of Mold Transformer (몰드변압기의 부분방전 측정 시스템)

  • Kang, Dong-Sik;Sun, Jong-Ho;Lim, Tae-Hoon;Hwang, Don-Ha;Kim, Yong-Joo;Kweon, Dong-Jin;Oeu, Soo-Young
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1891-1893
    • /
    • 2003
  • In order to development of diagnosis system for mold transformer, partial discharge measurement technique is recommended the best effective method for the evaluation of insulation condition. However, this technique was not applied to mold transformer yet. The purpose of this paper is to describe the method of partial discharge measurement for mold transformer. As we reviewed on-line test technique, sensor, transducer of pulse signal processing, set-up of test circuit for loading back device and now testing.

  • PDF

Assessment of Insulation Condition for Generator Rotor Windings (발전기 회전자 권선의 건전성 평가)

  • Lee, Young-Jun;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.59-60
    • /
    • 2006
  • A shorted-turn test was performed at the Pyungtaek combined cycle power plant on gas turbine generators. The test was conducted using a permanent flux probe and on-line shorted-turn diagnosis system. The permanent flux probe installed in the generator air gap senses the field winding slot leakage flux and produces a voltage proportional to the rate of change signature unique to each field winding. We have also applied a voltage waveform analysis technique that can identify the pole location, slot number and number of shorted-turn with each slot.

  • PDF

Characteristics of Ceramic Coupler for On-line Partial Discharge Measurement in High Voltage Rotating Machines (고압 회전기 On-line 부분방전 측정용 Ceramic Coupler 특성)

  • Gang, Dong-Sik;Yun, Dae-Hui;Kim, Yong-Ju;Lee, Hong-Sik;Yun, Yeong-Ho;Park, Jeong-Hu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.5
    • /
    • pp.204-212
    • /
    • 2002
  • In order to improve the reliability of high voltage rotating machines, it is necessary to understand the breakdown mechanism of stator windings. Especially partial discharge(PD) inception and growth are important in stator winding insulation. Recently, many research on the diagnosis of stator winding insulation for large rotating machines have been developed since the 1970s. Capacitive couplers have been the most widely used sensor for on-line partial discharge detection in rotating machines. This paper deals with the electrical on-line monitor characteristics of ceramic coupler(CC) which has been developed to continuously measure the PD activity in operating high voltage motor stator windings on site. We investigated the electrical characteristics(PD quantity, breakdown voltage and frequency response) to develop CC. This paper presents frequency characteristics and laboratory test result to compare conventional 80([F] epoxy-mica coupler(EMC) and 105[pF] CC for PD measurement with 6.6㎸ model stator windings.

Experimental Study on Prediction and Diagnosis of Leakage and Water Absorption in Water-Cooled Generator Stator Windings by Drying Process Analysis (수냉각 발전기 고정자 권선의 건조 과정 분석을 통한 누설 및 흡습 예측 진단에 관한 실험적 연구)

  • Kim, Hee-Soo;Bae, Yong-Chae;Lee, Wook-Ryun;Lee, Doo-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.9
    • /
    • pp.867-873
    • /
    • 2010
  • The failure of water-cooled generator stator windings as a result of insulation breakdown due to coolant water leaks and water absorption often occurs worldwide. Such failure can cause severe grid-related accidents as well as huge economic losses. More than 50% of domestic generators have been operated for over 15 years, and therefore, they exhibit signs of aging. Leaking and water-absorbing windings are often found during an overhaul. In an existing method for evaluating the integrity of generator stator windings, the drying process of the interior of the windings is ignored and only final leak tests are performed. In this study, it is shown that water leaks and water absorption in stator windings can be detected indirectly through vacuum pattern analysis in the vacuum drying mode, which is the used in the preparation stage of the leak test.

Insulation Characteristics and Thermography Diagnosis of Porcelain Insulators for the Distribution Systems (배전용 자기재 현수애자의 절연특성과 열화상 진단)

  • Joung, Jong-Man;Kim, Dong-Myeong;Choi, Myung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.4
    • /
    • pp.267-271
    • /
    • 2011
  • The insulating characteristics and temperature rise behaviors of porcelain suspension insulators were investigated. The testing insulators had used in the distribution systems normally and were sampled. Firstly, leakage current was measured and its impedance was calculated. The leakage current of good insulators is 0.2 mA and its impedance is 66 $M{\Omega}$. The worse insulators have lower impedance and the insulators having below 15 $M{\Omega}$ take place flashover at the high frequency voltage flashover test. Secondly, the temperature rise characteristics were analyzed depending on leakage current and its impedance. Surface temperature of insulators was measured for 30 minutes and until its saturation after voltage was applied. The temperature rise of insulators having 15 $M{\Omega}$ is about $14.5^{\circ}C$ above the ambient temperature. Lastly, the heating behaviors of 3 insulators in a string was analyzed. Any insulator in the string does not generate heat so far as it has at least one sound insulator. On the other hand, all the insulators in the string are bad if the string have any heating insulator.

Performance Verification and Improvement of UHF Sensor for the Increasement of the Partial Discharge Detection Reliability (부분방전검출 신뢰도 향상을 위한 UHF 센서개선 및 성능검증)

  • Kim, Won-Gyu;Kim, Min-Soo;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1461-1466
    • /
    • 2014
  • GIS(Gas Insulated Switchgear) is important power apparatus which have strong dielectric strength, supply electric power and is a part of the power system. Most substation type is configured as GIS. Recently, because of continuous increasement of GIS demand resulted from high quality & big capacity of electric power, the necessity of the preventive & diagnosis system is being expanded gradually. GIS partial discharge occurred on the UHF band is detected effectively by the method to IEC 60270 that recommend to be able to detect the apparent minimum discharge, 5 pC. Additionally, the UHF sensor should be installed to detect PD signal if Partial discharge signal, 5 pC occur in every part of GIS. Currently PD diagnosis system applying UHF sensor for GIS with various voltage level like 154 kV, 345 kV, 765 kV have been operated. And it is necessary to measure and analyze insulation breakdown phenomenon of inside GIS exactly. In this paper, we proposed Fat-dipole patch UHF sensor that is developed and more sensitive, excellent wide-range characteristic than the exising UHF sensor. And we performed KERI (Korea Electrotechnology Research Institute) reference test, which showed the excellent result for the all tests.