Browse > Article
http://dx.doi.org/10.5370/KIEE.2014.63.10.1461

Performance Verification and Improvement of UHF Sensor for the Increasement of the Partial Discharge Detection Reliability  

Kim, Won-Gyu (Dept. of Electronics and Electrical Engineering, Kyungpook National University)
Kim, Min-Soo (Hyosung Corporation Power System Performance Unit)
Baek, Young-Sik (Dept. of Electronics and Electrical Engineering, Kyungpook National University)
Publication Information
The Transactions of The Korean Institute of Electrical Engineers / v.63, no.10, 2014 , pp. 1461-1466 More about this Journal
Abstract
GIS(Gas Insulated Switchgear) is important power apparatus which have strong dielectric strength, supply electric power and is a part of the power system. Most substation type is configured as GIS. Recently, because of continuous increasement of GIS demand resulted from high quality & big capacity of electric power, the necessity of the preventive & diagnosis system is being expanded gradually. GIS partial discharge occurred on the UHF band is detected effectively by the method to IEC 60270 that recommend to be able to detect the apparent minimum discharge, 5 pC. Additionally, the UHF sensor should be installed to detect PD signal if Partial discharge signal, 5 pC occur in every part of GIS. Currently PD diagnosis system applying UHF sensor for GIS with various voltage level like 154 kV, 345 kV, 765 kV have been operated. And it is necessary to measure and analyze insulation breakdown phenomenon of inside GIS exactly. In this paper, we proposed Fat-dipole patch UHF sensor that is developed and more sensitive, excellent wide-range characteristic than the exising UHF sensor. And we performed KERI (Korea Electrotechnology Research Institute) reference test, which showed the excellent result for the all tests.
Keywords
GIS(Gas Insulated Switchgear); Fat-dipole patch; PD(Partial Discharge); UHF sensor;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 "Power Office Total Information System", the Korea Electric Power Cooperation, 2013.
2 Jin-yeol Yoon, Gi-jun Park, and Sun-geun Goo, "Partial Discharge Detection of GIS Technology Research. (Final Report), 2002. 08.
3 Mun-Gyu Choi, Hanju Cha, "UHF Sensor Location Optimization for Partial Discharge Signals Detection Method" Trans. KIEE, Vol. 63, No.3, MAR. 2014   과학기술학회마을   DOI   ScienceOn
4 Seung-Min Lee, "A Study of the Method for External Noise Shielding using the GIS UHF Sensor Module Applied to the Partial Discharge Signal Sensitivity and Method of Frequency Transforming in the Internal GIS", Trans, KIEE, Vol. 59, No.4, APR. 2010.   과학기술학회마을
5 Jae-Ryong Jung, En-Tae Lyu, Min-Soo Kim, Young-Jun Choi, "Research of UHF Sensor Optimal Arrangement for 25.8kV C-GIS", KIEE Summer conference, JUL. 2010.
6 Taesik Choi, Jae Ryong Jung, Min Soo Kim, Jung Bae Kim and Hak Sung Lee, "Development of the On-line iPDM System for the PD Diagnosis for 25.8kV C-GIS", International Conference on Condition Monitoring and Diagnosis, D2-08, APR. 2008.
7 http://www.rfdh.com/rfdb/vswr.htm
8 Won-pyo Song, Jung-Bae Kim, Min-Soo Kim, Jae-Ryong Jung, "UHF Narrow Band Type Partial Discharge Diagnosis Method for the Internal Insulation Performance Verification of the Gas Insulated Switchgear", Trans. KIEE, Vol. 54C, No.9, SEP. 2005.   과학기술학회마을