• 제목/요약/키워드: Insulating Oil

검색결과 221건 처리시간 0.036초

유동대전에 의한 절연유중의 정전기 방전기구와 대책에 관한 연구 (A Study on the Mechanism and Countermeasure of Electrostatic Discharge in Insulating Oil by Streaming Electrification)

  • 박광현;임헌찬;김두식;황명환;육재호;이덕출
    • 한국안전학회지
    • /
    • 제8권2호
    • /
    • pp.10-15
    • /
    • 1993
  • In this paper, it is studied the electrostatic discharge In Insulating oil for the purpose of the technical control of the streaming electrification resulted from the interface between an insulating liquid and a solid. The streaming current increases exponentially with flow rate and In region of lower than 50[$^{\circ}C$]but decreases at higher than the same temperature. The phenomena of electrostatic discharge appear at an interface between measuring tank and insulating oil when the seven sheets of gauzes are inserted in electrification apparatus. And those of partial or surface discharge are shown when eight sheets are inserted.

  • PDF

폐콘덴서의 절록유 중에 함유된 PCB 분석에 관한 연구 (A Study on PCB Analysis of Insulating Oil in Waste Condenser)

  • 김귀자;박재주
    • Environmental Analysis Health and Toxicology
    • /
    • 제4권1_2호
    • /
    • pp.11-17
    • /
    • 1989
  • A quantitative analytical method of highly concentrated PCB is established in the research. With the quantitative analytical method PCB of insulating oil was examined. The following conclusions are derived from this research. 1. The recovery ratio was 95.7% with the quantitative analytical method, which indicates it can be used for the analysis of PCB. 2. PCB concentration of insulation oil in waste condenser was found to be 21.2% thru 13.85% , which was highly concentrated. 3. PCB insulation oil in waste condenser was same as PCB-42.

  • PDF

식물유 및 광유를 사용한 배전변압기의 열열화에 따른 절연유의 코로나 개시전압 및 전기적 특성에 대한 연구 (A Study on Corona Inception Voltage and Dielectric Characteristics of Thermally Aged Mineral and Vegetable Insulation Oil in Medium Voltage Power Transformer)

  • 정중일;허창수
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1745-1750
    • /
    • 2017
  • Starting from the distribution transformer, the insulation oil for the oil immersed power transformer is being used to convert the vegetable oil from the existing mineral oil. Vegetable oil is better in temperature characteristics and insulation performance, is not toxic, and has better biodegradable characteristic than that of mineral oil. In order to investigate the corona inception voltage and dieclectic charateristics of the two insulating oils, three oil immersed transformers using mineral oil and vegetable oil were made and thermal cyclic aged. In this paper, the changes in the corona discharge inception voltage, chemical and electrical properties of the two sampled insulating oils from the transformers had been studied.

OF 케이블 절연유의 특성 변화에 따른 경년열화진단 (The Aging Diagnosis of OF Cable Insulation Oil by Characteristic Change)

  • 윤구섭;정우성;김철운;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.35-40
    • /
    • 1997
  • As demand of electric power are growing and transmission line limited owing to enlargement of the downtown area The eonfidence of underground transmission cable which shows gradual growth are high. It is found whether insulating ability is good or not. In this paper, The exper iment result is shown that the fall of insulating ability and take preventive measure through the analysis of tans, water content, dielectric breakdown voltage, total acid number, volume resistivity , and gas in the oil in an accordance with the characteristic change of oil used very much for insulating oil of cable.

  • PDF

X선 장치용 절연유의 방사선 유기전류에 관한 연구 (A Study on the Radiation Induced Current of X-ray Insulating Oil)

  • 김영일;정연택;이덕출
    • 대한전기학회논문지
    • /
    • 제38권7호
    • /
    • pp.549-556
    • /
    • 1989
  • Radiation induced current of the insulating oil used for X-ray tube housing was investigated in this paper. The X-ray induced current increased in proportion to the X-ray intensity and X-ray wave length and was greatly affected by the temperature of the insulating oil and the gap length` however, the current was not varied by the amount of the X-ray absorbed. The results suggest that one must consider the following problems as important factors for X-ray machine design and normal operation: cooling system of the X-ray tube housing, X-ray intensity, increasing temperature due to continuous operation, years used, and oil exchange and management.

  • PDF

광섬유 센서를 이용한 절연유내의 부분방전 위치검출에 관한 연구 (A Study on Partial Discharge Location in Insulating Oil using Optical Fiber Sensors)

  • 권태호;이종길;이준호
    • 한국전기전자재료학회논문지
    • /
    • 제16권9호
    • /
    • pp.838-841
    • /
    • 2003
  • This paper shows results on the application of optical fiber sensors(OFS) for locations of ultrasonic signals in silicon insulating oil. The OFS system based on the principle of Sagnac interferometry has been designed and established for this work. The hollowed cylindrical mandrel wound by single mode optical fiber was used as a sensing component and ultrasonic signals which simulate the partial discharge In the oil have been generated by PZT actuator operated with function generator. The experimental results shows that the OFS has a excellent performance for the PD location with resolutions less than 1$^{\circ}C$ error range in the miniature insulating oil tank.

식물성 절연유의 전력용 변압기 적용에 따른 문제점 고찰 및 전망 (Problem considerations and expectations in applying vegetable oil to power transformer)

  • 박현수;김지호;이향범
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.184-186
    • /
    • 2009
  • In past, transformer connection study was concentrated on efficiency improvement and life time broadening. But environmental side began to become important recently. In existing, quick transaction of mineral oil used to insulation oil of transformer is possibility to be difficult and causes environmental pollution in case of was outpoured and there is worry of fire occurrence. Accordingly, nonflammable performance becomes many interest in excellent vegetable oil because ignition point is high than mineral oil and environment friendly material. But, vegetable oil is cooling of transformer and insulation problem of insulating paper for cause of insulation oil special quality. Therefore, in this paper, special quality of vegetable oil that there are being a lot of mineral oil and the latest interest examined about problem and consideration item to be solved to analyzed comparison and applies vegetable oil to transformer for electric power.

  • PDF

역류산화공정을 이용한 고농도 PCBs 함유 절연유의 처리 (Treatment of Highly Concentrated PCB Containing Insulating Oil by Countercurrent Oxidation Process)

  • 이창순;김대익;유건상
    • 대한화학회지
    • /
    • 제61권4호
    • /
    • pp.143-150
    • /
    • 2017
  • 절연유에 높은 농도로 함유되어 있는 폴리염화바이페닐(PCB)을 처리하기 위해서 역류산화공정이 개발되었고 그 평가가 이루어졌다. 학산금속공업(주)로부터 구한 절연유 중의 PCBs의 함량은 1,512 ppm이었다. 역류산화공정은 산소의 흐름 속도와 반대되는 방향으로 자기 스스로 이동하는 자발적인 불꽃을 이용한다. 불꽃은 활성탄에 흡착되어 있는 PCBs를 제거함과 동시에 활성탄을 재생시킨다. 불꽃의 온도는 활성탄의 질량 손실과 역류산화공정 동안 배출되는 CO와 $CO_2$의 상대적인 비에 의해 결정하였고, 온도는 $650{\sim}850^{\circ}C$의 범위를 보였다. PCBs의 제거 효율은 무게비로 활성탄에 5%가 적재된 절연유를 1번의 역류산화공정을 거쳤을 때 99.99%이상을 나타내었다. 또한 60%의 절연유를 활성탄에 적재하여 3번의 연속적인 역류산화공정을 거쳤을 때 같은 제거 효율을 얻었다. 덧붙여서, 역류산화공정 동안 활성탄의 비표면적은 신탄의 수치와 비슷한 수준으로 회복되었다. 역류산화반응은 쉽고 경제적으로 절연유에 있는 고농도의 PCBs를 제거하는데 대단히 효과적이다는 것을 증명하였다.

방사선(放射線) 조사(照射) 중(中) 절연유(絶緣油)의 유기전류(誘起電流)에 관한 연구(硏究) (A Study on Radition-Induced Current in Insulating Oil during X-ray Irradiation)

  • 김영일;이덕출;정연택
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제11권1호
    • /
    • pp.33-41
    • /
    • 1988
  • This study was measured the radiation-induced current - X-ray dose, dose rate, X-ray quality, time, temperature, electric field characteristics and the dependence of gap length in insulating oil under of D.C. Voltage before, during and after X-ray irradiation. The obtained results can be summarized as following. 1. The radiation - induced current is more the dependence of X-ray quality (tube voltage) than quantity (tube current), the dependence of quantity is appeared at the high than low X-.ay tube voltage. 2. The dependence of dose rate is appeared at the more dose rate, and ${\triangle}\;=\;0.64{\sim}0.74$. 3. The higher temperature of insulating oil and X-ray tube voltage (X-ray quality) is increased, at the low electric field, the more radiation-induced current. 4. $G_{eq}-G_{o}(={\triangle}G)$ is increased at the low than high temperature, high than low X-ray quality. 5. The dependence of temperature is appeared before than during X-ray irradiation. 6. The RIC saturation region is appeared at the high than low insulating oil temperature during (1000 V/cm above) than before (4000 V/cm above) X-ray irradiation.

  • PDF