• Title/Summary/Keyword: Installation site

Search Result 654, Processing Time 0.029 seconds

A Study on research of suitable site of Floated PV System (수상 태양광발전 적지조사 기법에 관한 연구)

  • Choi, Hyung-Cheol;Kim, Ye-Jin;Kim, Eun-Gi;Lee, Jong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1400-1401
    • /
    • 2011
  • RPS(Renewable Portfolio Standard) recently with the introduction of a new solar power development as the market expands, land shortage of solar power as an alternative site for installing solar water development has emerged. Solar water dams, reservoirs and water by taking advantage of available solar power development a new concept of private forest land in a way does not involve destruction of the forest land and water resources through efficient use of environmentally friendly energy production and water quality improvement There are a variety of benefits. This paper won the nation's first solar power to enforce the selection of the optimal location for solar power's award for planning theory and research techniques are intended to establish. Award of the solar system through the analysis of a few research-related materials and renewable energy systems project implementation process to establish an initial investigation techniques as well as the existing dam located about fitness will be assessed. In this study, solar water conducting business in the current analysis with considerable planning and installation of solar installation for the economic and environmental cost of the evaluation period and is expected to be able to give you one.

  • PDF

Preliminary investigation of a proposed site for SFCL installation in the power systems (전력계통에서의 초전도 한류기 설치를 위한 기초적 연구)

  • 김용학;윤용범;최효상;현옥배
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.2
    • /
    • pp.38-41
    • /
    • 2002
  • We have conducted Preliminary investigation to propose a suitable site for superconducting fault current limiter (SFCL) installation in the KEPCOs 154kV grid This investigation limited the application SFCL to the bus-tie position of the grid in the Seoul area. First, we calculated maximum Potential fault current for all substations. Then, among substations where the fault current exceeds the CB capacity, rye selected two substations where buses are being operated untied. For the selected two. S S/S and M S/S. fault currents at the M S/S were estimated to be 22.5㎄ and 24.3㎄ for two buses untied respectively, but 44.2㎄ if buses were tied. Simulation using a hypothetical SFCL of 5 Ohm impedance showed that it controlled the fault current up to 20. 1㎄ for bus-tie Position, 28.4㎄ and 29.9㎄ for both buses. respectively, each of which are under the capacity of the currently installed 31.5㎄ GIS. For both substations a SFCL with 5 Ohm impedance successfully controls the fault current under the CB capacity, and 10 Ohm SFCL may be recommendable to maximize the SFCL effect.

A Study on Making Upward Lighting Ratio Regulation for Lighting Zone Based on the Light Distribution of Streetlight Site Survey (가로등 배광의 실태조사를 통한 조명환경관리구역별 상향광속률 기준 마련을 위한 연구)

  • Lee, Young-Jin;Seo, Young-Seok;Oh, Min-Seok;Kim, Hway-Suh
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.10
    • /
    • pp.9-15
    • /
    • 2012
  • There have been light pollution standards just for architectural lighting and sign in the "Light Pollution Abatement Law" so far. However, both of them regulate only one of the three main light pollution elements-"Glare". Therefore, it is imperative to do research on the other two light pollution elements-"Upward" and "Light Trespass" and make proper restriction. Subsequently, this study focuses on the upward light from the street light and suggests its analysis method. Eventually, this study aims to make viable management which is suitable for the nation and, in addition, to suggest appropriate level of restriction to "Light Pollution Abatement Law" by doing site survey.

Optimal location of Batcher Plant using Modified Steiner point (수정된 Steiner Point를 이용한 Batcher Plant의 최적 위치 선정)

  • Ha, Kwon-Yeol;Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.10
    • /
    • pp.39-46
    • /
    • 2015
  • REMICON(Ready Mixed Concrete), the most essential material of construction work, is produced from facility called "Batcher plant." In order to produce Remicon, Batcher Plant needs to be supplied with basic raw material such as ballast, sand, cement, admixture and water. In remicon industry, overland transport vehicles are used during the whole manufacturing process from producing to infilling at the construction site. Thus, the transportation cost sums up be to 20 percent of whole manufacturing cost and transport capacity and distance travelled have direct and major effect on manufacturing costs. This paper suggests a method to find optimal location of batcher plant using modified Steiner point, suggesting the most effective and flexible connection through among construction site, aggregate, cement and remicon producing plant. This paper also proposes reducing of transport cost at maximum 60% by calculation through optimized plant location. The modified Steiner point theory proposed in this paper also can be applied to optimal location of a $2^{ry}$ substation or MCC panel for minimizing of power loss, voltage drop, line distance and etc.

Analysis on the Effect of Local Climate on the Unit-type Ground Heat Exchanger (지역 기후가 유닛형 지중열교환기 성능에 미치는 영향)

  • Bae, Sangmu;Kim, Jae-Min;Nam, Yujin
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.1
    • /
    • pp.67-76
    • /
    • 2019
  • A ground source heat pump (GSHP) system can stable system operation by using underground heat source and has high reliability for energy production. However, wide-spread of the GSHP system is delayed to high initial investment costs. In previous studies, horizontal and unit-type ground heat exchanger (GHX) have developed to overcome disadvantages such as high initial cost. However, these performances of GHXs are greatly influenced by climate and weather conditions. It is necessary to analyze the performance of GHX according to the ground temperature change in the installation site. In this study, the ground temperature of each installation site confirmed and performance of unit-type GHX quantitatively analyzed by numerical analysis. As the result, the performance of the unit type GHX was 33.9 W/m in Seoul, 34.2 W/m in Daejeon, and 37.2 W/m in Busan.The result showed the difference performance of GHX according to local climate was maximum of 9.7%.

Determination of a Substation and Installation Site for applying Superconducting Cable/FCL to Real Power Grid (초전도케이블/한류기 실계통 적용 변전소 및 설치위치 선정 기술검토)

  • Yang, B.M.;Won, Y.J.;Kim, B.H.;Kang, J.W.;Yoon, J.Y.;Lee, S.R.;Moon, Y.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.55-59
    • /
    • 2009
  • In attempts to closely study the effect of high efficiency, friendly environment HTS(High Temperature Superconducting) cable and SFCL(Superconducting Fault Current Limiters) on power system, several projects were carried out around the world. Promising results have been achieved in terms of cable capacity and reliability. commercial HTS cable and SFCL, however, must not only be only be feasible, but meet practical requirements as well. To facilitate the transition of HTS cable technology from the Lab. to the Real Grid, a New project for applying 22.9kV HTS cables and SFCL to the commercial Power Grid supported by Government has just started in KEPCO. Target of this project is to operate two 22.9kV, 50MVA, 150MVA HTS cables and two 22.9kV 630A, 3000A SFCL in a KEPCO Grid in order to demonstrate its reliability and stable operation. This paper will present the technology for selecting appropriate site and its plan for installation & operating of 22.9kV HTS cables & SFCL in KEPCO Grid.

A Study on the Revision of the Cost accountingfor Sidewalk Block Pavement Maintenance and Repair Work (보도용 블록포장 유지보수 공사 원가산정기준 개정 연구)

  • Oh, Jae-Hoon;An, Bang-Yul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.271-272
    • /
    • 2021
  • The maintenance and repair work of sidewalk block pavement is a construction that requires a large amount of budget to be invested every year. It is important to establish an appropriate standards for estimating construction cost to ensure proper budgeting and quality. In this study, the standards for estimating the cost of maintenance and construction work for sidewalk blocks that can be applied to the construction volume classified according to the site conditions, construction type, and equipment use differentiated from new construction was established. As a result, the daily construction volume was presented by reflecting excavator and truck as equipment in the combination of paver and common worker. The re-installation was applied by separating the construction volume of sections with general blocks and induction/raised blocks based on the installation of sidewalk blocks after demolition. Generally if block cutting is necessary, the precision construction conditions using a cutting machine were taken into consideration to secure the construction quality. In addition, it has been revised to apply classified construction volume into A and B-Type depending on the park and site conditions.

  • PDF

Deriving Critical Management Factors based on Case Studies of Multi-trade MEP Ceiling Rack Prefabrication (복합공종 MEP 천정 선조립 공법 사례조사를 통한 단계별 중점관리사항 도출)

  • Lee, Dongmin;Jang, Sejun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.76-77
    • /
    • 2015
  • In construction industry, management of construction factors such as cost, schedule, quality and safety is the most important key for delivering successful projects. According to the Smart Market Report, a magazine specialized in construction industry, recently said 'Off-site Prefabrication' is a significant trend related with construction productivity in global construction industry. It is a kind of practice shift from On-site to Off-site. A lot of general contractors in oversea have been using 'Multi-trade MEP Ceiling Rack Prefabrication' method for getting benefits such as decreased cost & schedule and increased labor productivity. Thus, in this paper, critical management factors at each phase from design to installation was derived by researching case studies. Forwardly, it can be a basic guideline for applying Multi-trade MEP Ceiling Rack Prefabrication in Korea construction industry.

  • PDF

A Study on the Site Selection of Unmanned Post Office Considering the Operation Cost by the Mail Volume (우편물량 규모에 따른 운영비용 기준의 무인화 대상우체국 선정에 관한 연구)

  • Choi, Jiyoung;Lee, Jeong-hun
    • Korean Management Science Review
    • /
    • v.33 no.3
    • /
    • pp.1-18
    • /
    • 2016
  • Recently, ordinary mail is decreasing continuously by the development of ICT (Information and Communications Technology) including E-mail, messenger service, and etc. On the contrary, parcel post is increasing by the increase of online shopping, home shopping, and etc. Aside from these changes, the demand for various mail acceptance and delivery means is increasing with the increase of single households and dual-income couples. To overcome these environmental changes, Korea Post installs unmanned post offices which are composed of various unmanned mail acceptance and delivery postal systems. In this paper, we propose the methodological approach for the site selection of unmanned post office among the existing post offices and the installation standard of unmanned postal system considering the operation cost by the mail volume.

The Prospect and the Problems at Site of ABC-type Distribution (ABC 배전방식의 전망과 현장 적용상의 문제점 검토)

  • Park, Joung-Shin;Yi, Sue-Muk;Kang, Won-Koo;Kim, Seung-Don
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.504-506
    • /
    • 2000
  • In other advanced countries, an ABC-type distribution was employed few decades ago. It was, however, introduced, in this country, in late 1999. In order to apply it to the sites, several things have to be improved to comply with Korean distribution condition. It is very important to investigate the prospect and the problems in applying this type of distribution at site. To effectively employ it at site ASAP, follows have to be considered: easy installation of a transformer the development of branch gear, easy connections, the preventive diagnosis technique of insulating materials for ABC applications, etc. This paper describes the problems and the advanced plans of ABC-type distribution, and in construction.

  • PDF