• 제목/요약/키워드: Installation condition

검색결과 938건 처리시간 0.026초

인공어초 사후관리 현황과 발전방향 (Management after installation of artificial reefs;Present Condition and Development Scheme)

  • 이성일;안승환;김동선
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.160-161
    • /
    • 2005
  • It is important to manage artificial fish reefs with installation for restoration. The instruments of survey for artificial reefs condition(location, amount etc.) is Side Scan Sonar and Multi-beam sonar. The efficient and economic survey of the artificial reefs facility is the complete survey of the SSS(Side Scan Sonar) in all area first and then the survey of the artificial reefs by MBES(Multi Beam Echo Sounder) in the finding area.

  • PDF

콘크리트의 저항률 특성 분석 (Characteristic Analysis for Resistivity of Concrete)

  • 김성삼;최종규;김재성;고희석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.457-459
    • /
    • 2006
  • In this paper was analyzed and compared the resistivity characteristic of concrete between moisture condition and dry condition to measure the variation of resistivity by water after making concrete scale block. The resistivity was decreased when the moisture of concrete block was gradually increased.

  • PDF

전압강하를 고려한 저압간선의 설계 알고리즘 (Algorithm for the Low-Voltage Feeder Design in Consideration of Voltage Drop)

  • 고영곤;최홍규;조계술
    • 조명전기설비학회논문지
    • /
    • 제16권3호
    • /
    • pp.84-92
    • /
    • 2002
  • 저압간선의 굵기는 계통의 전압강하, 간선의 포설조건별 온도 보정계수를 적용한 허용 전류 및 간션의 임피 던스 값에 따라 결정된다. 따라서, 간선의 허용전류 값올 결정하기 위하여 간선의 포셜조건에 따른 적정 보정계 수가 적용되어야 하며, 저압간선의 정확한 임피던스 값을 분석하기 위하여 간선의 종류, 간선의 규격, 포셜조건 에 따른 온도, 표피효과 및 근접 효과 둥이 고려되어야 한다. 본 연구는 저압계통의 전압강하를 고려한 간선의 굵기 산정에 대한 체계적인 설계 흐름도를 제시 하였으며, 일반적인 계산 방식에 비하여 오차가 적은 계수로서 저압간선 굵기 선정 설계 실무에 적용할 수 있는 계산 방식을 연구하였다.

설비 투자비용의 관점에서 쿨루프와 옥상녹화의 비교 평가: 경북대학교 캠퍼스 사례를 중심으로 (Comparative Evaluation between Cool Roof and Green Roof in terms of Installation Cost: a Case Study of KNU Campus)

  • 김준우;엄정섭
    • 환경영향평가
    • /
    • 제21권6호
    • /
    • pp.927-939
    • /
    • 2012
  • Cool roofs are currently being emerged as one of important mechanism to save energy in relation to the building. Although green roof has already gained nation-wide recognition as a typical method of energy saving in the roof, this approach did not provide a realistic evidence that is economically feasible in terms of installation cost. This research is primarily intended to compare installation cost between the two techniques. This research proposes a comparative evaluation framework in a more objective and quantitative way for an installation cost between the two techniques. Kyungpook National University (KNU) was selected as a survey objective and an exhaustive and realistic comparison of installation cost between the two techniques was conducted, based on Life Cycle Cost analysis (initial investment cost, maintenance cost, dismantling and waste disposal expense). It was possible to identify that installation cost of cool roofs is 4.7 times cheaper than that of green roof. Also present value based on probabilistic approach was identified as 0.25 (4.95) higher than the installation cost on the assumption of constant price and interest. It is expected that much more installation cost for the large scale green roof will be required since small-size green roof selected as a survey objective in this study could be operated under less initial installation and maintenance condition.

A novel approach for predicting lateral displacement caused by pile installation

  • Li, Chao;Zou, Jin-feng;Li, Lin
    • Geomechanics and Engineering
    • /
    • 제20권2호
    • /
    • pp.147-154
    • /
    • 2020
  • A novel approach for predicting lateral displacement caused by pile installation in anisotropic clay is presented, on the basis of the cylindrical and spherical cavities expansion theory. The K0-based modified Cam-clay (K0-MCC) model is adopted for the K0-consolidated clay and the process of pile installation is taken as the cavity expansion problem in undrained condition. The radial displacement of plastic region is obtained by combining the cavity wall boundary and the elastic-plastic (EP) boundary conditions. The predicted equations of lateral displacement during single pile and multi-pile installation are proposed, and the hydraulic fracture problem in the vicinity of the pile tip is investigated. The comparison between the lateral displacement obtained from the presented approach and the measured data from Chai et al. (2005) is carried out and shows a good agreement. It is suggested that the presented approach is a useful tool for the design of soft subsoil improvement resulting from the pile installation.

Sensitive analysis of design factor for the optimum design of PVT system

  • Jeong, Yong-Dae;Nam, Yujin
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.5-11
    • /
    • 2015
  • Purpose: Recently, renewable energy system has been widely used to reduce the energy consumption and CO2 emission of building. A photovoltaic/thermal(PVT) system is a kind of efficient energy uses, which is combined with photovoltaic module and solar thermal collector. PVT system removes heat from PV module by through thermal fluid to raise the performance efficiency of the PV system. However, though PVT system has the merit of the improved efficiency in theoretical approach, there have been few performance analysis for PVT system using the dynamic energy simulation. In this study, in order to establish the optimum design method of this system, simulation was conducted by using individual system modules. Method: For the dynamic simulation, TRNSYS17 was used and local weather data was utilized. Furthermore, the system performance in various installation condition was calculated by case studies. Result: As a result, the amount of electric generation and heat production in each case was found by the simulation. The gap of system performance was also evident according to the installation condition.

실내 시험기에 의한 지오그리드의 시공 시 손상 평가 (Installation Damage Assessment of Geogrids by Laboratory Tester)

  • 진용범;변성원;전한용
    • 한국지반신소재학회논문집
    • /
    • 제5권4호
    • /
    • pp.43-47
    • /
    • 2006
  • 다짐조건을 달리하여 3가지 종류 지오그리드의 내시공성을 측정하였다. 이 실험은 ENV ISO 10722-1에 근거하여 실행되었다. 채움재와 관계없이 다짐횟수가 증가할수록 지오그리드의 인장강도는 감소하였으며, 지오그리드 종류에 따라 감소되는 경향이 다르게 나타남을 알 수 있었다. Woven 및 warp-knitted type 지오그리드의 경우 접합형 지오그리드에 비해 더 큰 감소경향을 나타내었다.

  • PDF

우리나라주택조명 실태조사 연구 (A Research on the Actual Condition of Korean Residential Lightings)

  • 지철근
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제2권1호
    • /
    • pp.59-64
    • /
    • 1988
  • 우리나라 주택 조명에 대하여 조도 수준을 조사한 결과, 평균적으로 도시지역은 추천치의 1/3, 농어촌 지방은 추천치의 1/10에도 못미치는 것으로 나타났다. 따라서, 능률적인 활동과 주민 복지의 견지에서 조명등의 설비와 용량의 상당한 증대를 통하여 적당한 조도 수준을 얻는 것이 요망된다.

  • PDF

거실의 조명환경에 관한 실태조사 (A reserch on the actual condition of living lighting)

  • 안옥희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1991년도 추계학술발표회논문집
    • /
    • pp.11-13
    • /
    • 1991
  • The purpose of this study is to investigate the actual condtions of illumination circumstances in living room and the evaluation of residents. The investigation has been carried out in the house at deagu city. The investigation was conducted at two term of 1985 and 1991 years.

  • PDF

우리나라 사무소조명의 실태조사연구 (A Research on the actual condition of Korean office lighting)

  • 지철근
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제2권2호
    • /
    • pp.47-54
    • /
    • 1988
  • 우리나라 사무실조명의 실태조사결과, 평균조도는 대체로 추천조도의 1/2에도 미달되는 빈약한 조명상태이다. 활동능률측면이나, 국민보건측면에서도 적절한 전정시설의 증설로 조도 수준의 향상이 절실히 요망된다.

  • PDF