• Title/Summary/Keyword: Inner power

Search Result 842, Processing Time 0.026 seconds

Stability Analysis and Improvement of the Capacitor Current Active Damping of the LCL Filters in Grid-Connected Applications

  • Xu, Jinming;Xie, Shaojun;Zhang, Binfeng
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1565-1577
    • /
    • 2016
  • For grid-connected LCL-filtered inverters, dual-loop current control with an inner-loop active damping (AD) based on capacitor current feedback is generally used for the sake of current quality. However, existing studies on capacitor current feedback AD with a control delay do not reveal the mathematical relation among the dual-loop stability, capacitor current feedback factor, delay time and LCL parameters. The robustness was not investigated through mathematical derivations. Thus, this paper aims to provide a systematic study of dual-loop current control in a digitally-controlled inverter. At first, the stable region of the inner-loop AD is derived. Then, the dual-loop stability and robustness are analyzed by mathematical derivations when the inner-loop AD is stable and unstable. Robust design principles for the inner-loop AD feedback factor and the outer-loop current controller are derived. Most importantly, ensuring the stability of the inner-loop AD is critical for achieving high robustness against a large grid impedance. Then, several improved approaches are proposed and synthesized. The limitations and benefits of all of the approaches are identified to help engineers apply capacitor current feedback AD in practice.

Performance control analysis of concrete-filled steel tube sepa-rated spherical joint wind power tower

  • Yang Wen;Guangmao Xu;Xiazhi Wu;Zhaojian Li
    • Structural Engineering and Mechanics
    • /
    • v.87 no.2
    • /
    • pp.137-149
    • /
    • 2023
  • In this study, to explore the working performance of the CFST split spherical node wind power tower, two groups of CFST split spherical joint plane towers with different web wall thicknesses and a set of space systems were analyzed. The tower was subjected to a low-cycle repeated load test, and the hysteresis and skeleton curves were analyzed. ABAQUS finite element simulation was used for verification and comparison, and on this basis parameter expansion analysis was carried out. The results show that the failure mode of the wind power tower was divided into weld tear damage between belly bar, high strength bolt thread damage and belly rod flexion damage. In addition, increasing the wall thickness of the web member could render the hysteresis curve fuller. Finally, the bearing capacity of the separated spherical node wind power tower was high, but its plastic deformation ability was poor. The ultimate bearing capacity and ductility coefficient of the simulated specimens are positively correlated with web diameter ratio and web column stiffness ratio. When the diameter ratio of the web member was greater than 0.13, or the stiffness ratio γ of the web member to the column was greater than 0.022, the increase of the ultimate bearing capacity and ductility coefficient decreased significantly. In order to maximize the overall mechanical performance of the tower and improve its economy, it was suggested that the diameter ratio of the ventral rod be 0.11-0.13, while the stiffness ratio γ should be 0.02-0.022.

A CMOS Impulse Radio Ultra-Wideband Receiver for Inner/Inter-chip Wireless Interconnection

  • Nguyen, Chi Nhan;Duong, Hoai Nghia;Dinh, Van Anh
    • Journal of IKEEE
    • /
    • v.17 no.2
    • /
    • pp.176-181
    • /
    • 2013
  • This paper presents a CMOS impulse radio ultra-wideband (IR-UWB) receiver implemented using IBM 0.13um CMOS technology for inner/inter-chip wireless interconnection. The IR-UWB receiver is based on the non-coherent architecture which removes the complexity of RF architecture (such as DLL or PLL) and reduces power consumption. The receiver consists of three blocks: a low noise amplifier (LNA) with active balun, a correlator, and a comparator. Simulation results show the die area of the IR-UWB receiver of 0.2mm2, a power gain (S21) of 12.5dB, a noise figure (NF) of 3.05dB, an input return loss (S11) of less than -16.5dB, a conversion gain of 18dB, a NFDSB of 22. The receiver exhibits a third order intercept point (IIP3) of -1.3dBm and consumes 22.9mW of power on the 1.4V power supply.

Electrical Characteristics due to Inner Defect of Insulating Materials for Power Cable. (전력케이블 절연재료의 내부결함에 따른 전기적 특성)

  • Choi, Sang-Gi;Kim, Tag-Yong;Kim, Wang-Kon;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.27-30
    • /
    • 2003
  • Recently, on power system, it is used to high voltage of transmission and distribution due to safe power supply and have high quality and insulation in order to satisfy excellent insulator. Thus, according to underground of high voltage cable, is occurred break down by ground short. Therefore, it is used to high quality XLPE power cable to interrupt instantaneous voltage drop. If it appear inner defect for cable whose have high quality and insulation, it is reduced rapidly due to concentration of electrical field. After assemble to manufacture, in order to inspect cable condition, it is decided much inspection standard. In this paper, In inner defect of assembling cable at manufacture, for measure the variation of insulation condition by void. it tested the variation of insulating characteristics, using $\phi$-q-n distribution variation in partial discharge experiment.

  • PDF

Multi-Access Points Transmit Power Control Algorithm in Consideration of the Channel Estimation Error and the Multi Rate Service (채널추정 에러와 다중 전송률 서비스를 고려한 다수 개의 엑세스포인트 전송전력제어 알고리즘)

  • Oh, Changyoon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.25 no.4
    • /
    • pp.39-47
    • /
    • 2020
  • We propose a multi-access points transmit power control algorithm in consideration of the channel estimation error and the multi-rate service. In the real communication systems, the channel estimation at the receiver side is imperfect due to limited number of pilot symbol usage. Furthermore, the multi-rate service is supported. We theoretically prove the uniqueness and the convergence of the proposed algorithm in multi-rate service environment. The proposed algorithm composes of one inner loop part and one outer loop part. Simulation results show that 1) the inner loop algorithm guarantees convergence of the transmit power level and the multi-rate service, 2) the outer loop algorithm compensates for the channel estimation error.

The Influences of Fathers' Parenting Involvement and Maternal Inner Strength on Maternal Parenting Competence (아버지 양육참여와 어머니 내면의 힘이 어머니 양육효능감에 미치는 영향)

  • Choi, Mi-Kyung
    • Korean Journal of Childcare and Education
    • /
    • v.17 no.2
    • /
    • pp.47-68
    • /
    • 2021
  • Objective: This study investigated direct and indirect influences of fathers' parenting involvement on maternal parenting competence by exploring pathways between fathers' parenting involvement, maternal inner strength, and maternal parenting competence. Methods: A total of 329 mothers with 3-year-old children responded to online survey questionnaires, which included questions about fathers' parenting involvement, maternal inner strength, and maternal parenting competence. The data was analyzed by Pearson's correlation coefficients and Structural Equation Modeling. Results: It was observed that maternal inner strength perfectly mediated the association between father's parenting involvement and maternal parenting competence. More concretely, a direct effect of fathers' parenting involvement on maternal parenting competence was not found. It was also found that fathers' parenting involvement effects maternal parenting competence indirectly. The effect of fathers' parenting involvement on maternal inner strength was the greatest among all associations between fathers' parenting involvement, maternal inner strength, and maternal parenting competence. Conclusion/Implications: These findings have insights for research and practice, which emphasize the important considerations that enhancing maternal inner strength and the power of fathers' parenting involvement on maternal inner strength should be emphasized in order to improve maternal parenting competence.

Design of Triple Loop Current Control for Auxiliary Power Unit of Fuel Cell Train having Grid Connected Inverter Function (계통 연계 기능을 갖는 연료전지 철도차량 보조전원장치의 삼중 루프 전류 제어기 설계)

  • Kwon, Il-Seob;Baek, Seung-Woo;Kim, Hag-Wone;Cho, Kwan-Yual
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.4
    • /
    • pp.293-302
    • /
    • 2020
  • This study proposes a triple-loop current control method for the auxiliary power unit of fuel cell trains. The auxiliary power unit of fuel cell trains has a grid-connected function when power is supplied to the utility grid. Moreover, the auxiliary power unit of trains has a 1500 V DC link voltage; thus, PWM frequency cannot be increased to a high frequency. Owing to this low PWM frequency condition, creating a triple-loop design is difficult. In this study, a triple-loop controller is developed for a capacitor voltage controller in standalone mode that operates as an auxiliary power supply for trains and for a grid current controller in grid control mode with an inner capacitor voltage controller. The voltage controller employs an inductor current controller inner loop. To overcome low PWM frequency, a design method for the bandwidth of the capacitor voltage controller considering the bandwidth of the inner inductor current controller is described. The effectiveness of the proposed method is proven using PSIM simulation.

Two-loop Hysteretic Control of $3^{rd}$ Order Buck Converter

  • Veerachary, M.;Sharma, Deepen
    • Journal of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.310-317
    • /
    • 2007
  • In this paper, an analysis and hysteretic controller design of a $3^{rd}$ order buck converter is presented. The proposed hysteretic controller consists of an inner current-loop, just like the conventional cascade control scheme, and an outer voltage-loop for load voltage regulation. Although it is possible to include an inner current loop from different branches of the converter, from the feasibility and operational point of view, the load side capacitor current would be the better choice. The addition of an inner current-loop improves the dynamic performance of the converter while preserving the robustness of the hysteretic control. The controller formulation and closed-loop converter performance analysis are validated through computer simulations. Few experimental results of the proposed converter are given and compared with the buck converter.

Design and Fabrication of Light-Weight Composit Bus Bar (복합경량 부스바의 설계 및 제작)

  • Bae Joon-Han;Bea Duck-Kweon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.8
    • /
    • pp.334-340
    • /
    • 2006
  • Copper is widely used in electric wire, cable, conductor in electric devices. As the demand for electric power is increasing rapidly, electric power devices are getting amazingly bigger and complicated. The using of light-weight conductor can reduce the size and making cost of the electric devices. In high-frequency application, Electric current in a conductor tends to shift to the surface of the conductor, resulting in an uneven current distribution in the inner conductor. In the extreme case the current may essentially concentrate in the 'skin' of the inner conductor as a surface current. In high frequency application, therefore, inner area of copper conductor may replace with aluminum conductor, which reduces the weight of conductor. This paper describes the manufacture and evaluation of composite conductors made of copper and aluminum. The optimum extruding ratio was 16 at $300^{\circ}C$. The electrical resistance of manufactured composite bus bar was $57{\mu}{\Omega}$ at DC and $49.5{\mu}\{Omega}$ at 300Hz.

Analysis of a inner flow of ANDRICH type dryer (앤드리츠형 건조기의 내부 유동에 관한 해석)

  • Kim, T.S.;Choi, Y.H.;Choi, K.;Lee, Y.W.
    • Journal of Power System Engineering
    • /
    • v.10 no.2
    • /
    • pp.54-61
    • /
    • 2006
  • In order to prevent the environmental pollution, the dryers are commonly used to treat sludge that one of sewages is polluting the quality of water. Generally, the drying method is various as to the property of material and use. Rotary dryer is a good apparatus to treat them. The rotary dryer is the way that is to make substance transmission and heating using hot air between sludge particles and heated gas. In this paper, we performed a numerical analysis of the inner air flow of the ANDRICH type dryer through the changing rotational speed from 3rpm to 10rpm. A PIV can be applied to research a inner flow of ANDRICH type dryer.

  • PDF