Abstract
For grid-connected LCL-filtered inverters, dual-loop current control with an inner-loop active damping (AD) based on capacitor current feedback is generally used for the sake of current quality. However, existing studies on capacitor current feedback AD with a control delay do not reveal the mathematical relation among the dual-loop stability, capacitor current feedback factor, delay time and LCL parameters. The robustness was not investigated through mathematical derivations. Thus, this paper aims to provide a systematic study of dual-loop current control in a digitally-controlled inverter. At first, the stable region of the inner-loop AD is derived. Then, the dual-loop stability and robustness are analyzed by mathematical derivations when the inner-loop AD is stable and unstable. Robust design principles for the inner-loop AD feedback factor and the outer-loop current controller are derived. Most importantly, ensuring the stability of the inner-loop AD is critical for achieving high robustness against a large grid impedance. Then, several improved approaches are proposed and synthesized. The limitations and benefits of all of the approaches are identified to help engineers apply capacitor current feedback AD in practice.
Keywords
Active damping; Capacitor current feedback; Control delay; LCL filter; Stability;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 J. Dannehl, F. W. Fuchs, S. Hansen, and P. B. Thøgersen, “Investigation of active damping approaches for PI-based current control of grid-connected pulse width modulation converters with LCL filters,” IEEE Trans. Ind. Appl., Vol. 46, No. 4, pp. 1509-1517, Jul./Aug. 2010.   DOI
2 D. Pan, X. Ruan, C. Bao, W. Li, and X. Wang, “Capacitor-current-feedback active damping with reduced computation delay for improving robustness of LCL-type grid-connected inverter,” IEEE Trans. Power Electron., Vol. 29, No. 7, pp. 3414-3427, Jul. 2014.   DOI
3 J. Xu, S. Xie, J. Kan, and B. Zhang, "Research on stability of grid-connected LCL-filtered inverter with capacitor current feedback active damping control," in Proc. ICPE-ECCE Asia, pp. 682-687, 2015.
4 M. Orellana and R. Grino, "On the stability of discrete-time active damping methods for VSI converters with a LCL input filter," in Proc. IEEE IECON, pp.2378-2383, 2012.
5 X. Li, X. Wu, Y. Geng, X. Yuan, C. Xia, and X. Zhang, “Wide damping region for LCL-type grid-connected inverter with an improved capacitor-current-feedback method,” IEEE Trans. Power Electron., Vol. 30, No. 9, pp. 5247-5259, Sep. 2015.   DOI
6 R. Li, B. Liu, S. Duan, C. Zou, and L. Jiang, “Analysis and suppression of alias in digitally controlled inverters,” IEEE Trans. Ind. Informat., Vol. 10, No. 1, pp. 655-665, Feb. 2014.   DOI
7 D. Yang, X. Ruan, and H. Wu, “A real-time computation method with dual sampling modes to improve the current control performances of the LCL-type grid-connected inverter,” IEEE Trans. Ind. Electron., Vol. 62, No. 7, pp. 4563-4572, Jul. 2015.   DOI
8 Z. Zou, Z. Wang, and M. Cheng, “Modeling, analysis, and design of multifunction grid-interfaced inverters with output LCL filter,” IEEE Trans. Power Electron., Vol. 29, No. 7, pp. 3830-3839, Jul. 2014.   DOI
9 M. Wagner, T. Barth, R. Alvarez, C. Ditmanson, and S. Bernet, “Discrete-time active damping of LCL-resonance by proportional capacitor current feedback,” IEEE Trans. Ind. Appl., Vol. 50, No. 6, pp. 3911-3920, Nov./Dec. 2014.   DOI
10 W. Lu, N. Zhao, J. Wu, A. El Aroudi, and L. Zhou, “Filterbased perturbation control of low-frequency oscillation in voltage-mode H-bridge DC/AC inverter,” Int. J. Circ. Theor. Appl., Vol. 43, No.7, pp. 866-874, July 2015.   DOI
11 B. Lei, G. Xiao, X. Wu, Y. Kafle and L. Zheng, “Bifurcation analysis in a digitally controlled H-bridge grid-connected inverter,” Int. J. Bifurcat. Chaos, Vol. 24, No. 1, pp. 1-15, Jan. 2014.   DOI
12 X. Wu, G. Xiao, and B. Lei, “Simplified discrete-time modeling for convenient stability prediction and digital control design,” IEEE Trans. Power Electron., Vol. 28, No. 11, pp. 5333-5342, Nov. 2013.   DOI
13 B. Lei, G. Xiao, X. Wu, and L. Zheng, “A unified “scalar” discrete-time model for enhancing bifurcation prediction in digitally controlled H-bridge grid-connected inverter,” Int. J. Bifurcat. Chaos, Vol. 23, No. 7, pp. 1-17, Jul. 2013.   DOI
14 S. Yang, Q. Lei, F. Z. Peng, and Z. Qian, “A robust control scheme for grid-connected voltage-source inverters,” IEEE Trans. Ind. Electron., Vol. 58, No. 1, pp. 202-212, Jan. 2011.   DOI
15 D. Pan, X. Ruan, and C. Bao, “Optimized controller design for LCL-Type grid-connected inverter to achieve high robustness against grid-impedance variation,” IEEE Trans. Ind. Electron., Vol. 62, No. 3, pp. 1537-1547, Mar. 2015.   DOI
16 H. Zhao, Q.M.J. Wu, and A. Kawamura, “An accurate approach of nonlinearity compensation for VSI inverter output voltage,” IEEE Trans. Power Electron., Vol. 19, No. 4, pp. 1029-1035, July 2004.   DOI
17 J. Xu, S. Xie, and T. Tang, “Improved control strategy with grid-voltage feedforward for LCL-filter-based inverter connected to weak grid,” IET Power Electron., Vol. 7, No. 10, pp. 2660-2671, Oct. 2014.   DOI
18 P. Alemi, S.-Y. Jeong, and D.-C. Lee, “Active damping of LLCL filters using PR control for grid-connected threelevel T-type converters,” Journal of Power Electronics, Vol. 15, No. 3, pp.786-795, May 2015.   DOI
19 J.M. Guerrero, M. Leetmaa, F. Briz, A. Zamarron, and R.D. Lorenz, “Inverter nonlinearity effects in high-frequency signal-injection-based sensorless control methods,” IEEE Trans. Ind. Appl., Vol. 41, No. 2, pp. 618-626, Mar./Apr. 2005.   DOI
20 J. Xu, T. Tang, and S. Xie, “Research on low-order current harmonics rejections for grid-connected LCL-filtered inverters,” IET Power Electron., Vol.7, No.5, pp. 1227-1234, May 2014.   DOI
21 Y. Tang, P. C. Loh, P. Wang, F. H. Choo, F. Gao, and F. Blaabjerg, “Generalized design of high performance shunt active power filter with output LCL filter,” IEEE Trans. Ind. Electron., Vol. 59, No. 3, pp. 1443-1452, Mar. 2012.   DOI
22 J. Dannehl, C. Wessels, and F. Fuchs, “Limitations of voltage-oriented pi current control of grid-connected PWM rectifiers with LCL filters,” IEEE Trans. Ind. Electron., Vol. 56, No. 2, pp. 380-388, Feb. 2009.   DOI
23 X. Guo, X. You, X. Li, R. Hao, and D. Wang, “Design method for the LCL filters of three-phase voltage source PWM rectifiers,” Journal of Power Electronics, Vol. 12, No. 4, pp. 559-566, Jul. 2012.   DOI
24 F. Liu, Y. Zhou, S. Duan, J. Yin, B. Liu, and F. Liu, “Parameter design of a two-current-loop controller used in a grid-connected inverter system with LCL filter,” IEEE Trans. Power Electron., Vol. 56, No. 11, pp. 4483-4491, Nov. 2009.
25 M. Malinowski and S. Bernet, “A simple voltage sensorless active damping scheme for three-phase PWM converters with an LCL filter,” IEEE Trans. Ind. Electron., Vol. 55, No. 4, pp. 1876-1880, Apr. 2008.   DOI
26 J. Xu, S. Xie, and T. Tang, “Evaluations of current control in weak grid case for grid-connected LCL-filtered inverter,” IET Power Electron., Vol. 6, No. 2, pp. 227-234, Feb. 2013.   DOI
27 Y. Han, P. Shen, and J. M. Guerrero, “Stationary frame current control evaluations for three-phase grid-connected inverters with PVR-based active damped LCL filters,” Journal of Power Electronics, Vol. 16, No. 1, pp. 297-309, Jan. 2016.   DOI
28 J.B. Kwon, S.J. Yoon, and S. Choi, “Indirect current control for seamless transfer of three-phase utility interactive inverters,” IEEE Trans. Power Electron., Vol. 27, No. 2, pp. 773-781, Feb. 2012.   DOI
29 J. Xu, S. Xie, and T. Tang, “Active damping-based control for grid-connected LCL-filtered inverter with injected grid current feedback only,” IEEE Trans. Ind. Electron., Vol.61, No.9, pp. 4746-4758, Sep. 2014.   DOI
30 X Wang, F. Blaabjerg, and P. Loh, “Grid-current-feedback active damping for LCL resonance in grid-connected voltage source converters,” IEEE Trans. Power Electron., Vol. 31, No. 1, pp. 213-223, Jan. 2016.   DOI
31 L. A. Maccari Jr., J. R. Massing, L. Schuch, C. Rech, H. Pinheiro, R. C. L. F. Oliveira, and V. F. Montagner, “LMI-based control for grid-connected converters with LCL filters under uncertain parameters,” IEEE Trans. Power Electron., Vol. 29, No. 7, pp. 3776-3785, Jul, 2014.   DOI
32 J. Xu, S. Xie, and T. Tang, “Systematic current control strategy with pole assignment for grid-connected LCL-filtered inverters,” Journal of Power Electronics, Vol. 13, No. 3, pp. 447-257, May 2013.   DOI