• Title/Summary/Keyword: Inner loop

Search Result 314, Processing Time 0.031 seconds

Stability Analysis and Improvement of the Capacitor Current Active Damping of the LCL Filters in Grid-Connected Applications

  • Xu, Jinming;Xie, Shaojun;Zhang, Binfeng
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1565-1577
    • /
    • 2016
  • For grid-connected LCL-filtered inverters, dual-loop current control with an inner-loop active damping (AD) based on capacitor current feedback is generally used for the sake of current quality. However, existing studies on capacitor current feedback AD with a control delay do not reveal the mathematical relation among the dual-loop stability, capacitor current feedback factor, delay time and LCL parameters. The robustness was not investigated through mathematical derivations. Thus, this paper aims to provide a systematic study of dual-loop current control in a digitally-controlled inverter. At first, the stable region of the inner-loop AD is derived. Then, the dual-loop stability and robustness are analyzed by mathematical derivations when the inner-loop AD is stable and unstable. Robust design principles for the inner-loop AD feedback factor and the outer-loop current controller are derived. Most importantly, ensuring the stability of the inner-loop AD is critical for achieving high robustness against a large grid impedance. Then, several improved approaches are proposed and synthesized. The limitations and benefits of all of the approaches are identified to help engineers apply capacitor current feedback AD in practice.

Two-loop Hysteretic Control of $3^{rd}$ Order Buck Converter

  • Veerachary, M.;Sharma, Deepen
    • Journal of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.310-317
    • /
    • 2007
  • In this paper, an analysis and hysteretic controller design of a $3^{rd}$ order buck converter is presented. The proposed hysteretic controller consists of an inner current-loop, just like the conventional cascade control scheme, and an outer voltage-loop for load voltage regulation. Although it is possible to include an inner current loop from different branches of the converter, from the feasibility and operational point of view, the load side capacitor current would be the better choice. The addition of an inner current-loop improves the dynamic performance of the converter while preserving the robustness of the hysteretic control. The controller formulation and closed-loop converter performance analysis are validated through computer simulations. Few experimental results of the proposed converter are given and compared with the buck converter.

Design of Envelope Protection Algorithm for Helicopters (헬리콥터의 비행영역제한 알고리즘 설계)

  • Ko, Joon Soo;Park, Sungsu;Kim, Kyungmok
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.23 no.2
    • /
    • pp.63-68
    • /
    • 2015
  • This paper presents the algorithm for envelope protection of helicopters. The algorithm consists of two feedback control loops: inner loop and outer loop. As an inner loop control, model following control is designed to meet the ADS-33 handling qualities specification by minimizing the tracking errors between the responses of the actual model and those of the command filter. In order to implement envelope protection, saturation limiter is imposed to command channels in command filter, whose limits are computed corresponding to the envelope limit. Fast model predictive control is designed as an outer loop control to deal with saturation constraints generated by the inner loop envelope protection and also imposed by outer loop envelope protection variables. Simulation results show that the proposed algorithm yields good envelope protection performance.

Network Type Distributed Control of a System with Inner Loop Control Structure (내부 궤환 제어 구조를 갖는 시스템의 네트워크형 분산 제어)

  • Choi, Goon-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.100-108
    • /
    • 2014
  • In this paper, an idea of a network type distributed control of a system with inner loop control structure will be considered. Generally, in case of a control system with inner loop control structure, it is not easy to implement circuits and programming. Using network type distributed control structure, it will show how it is better than before. CAN(Controller Area Network) protocol which has been known that it has a high reliability on the signal in the various network protocols is used. Also, Arago's Disk System which has a inner loop control stucture is made to validate effectiveness of the proposed method.

Dynamic Compliance and its Compensation Control of HIVC Force Control System

  • Ba, Kai-xian;Yu, Bin;Li, Wen-feng;Wang, Dong-kun;Liu, Ya-liang;Ma, Guo-liang;Kong, Xiang-dong
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.1008-1020
    • /
    • 2018
  • In this paper, the dynamic compliance and its compensation control of the force control system on the highly integrated valve-controlled cylinder (HIVC), the joint driver of the hydraulic drive legged robot, is researched. During the robot motion process, the outer loop dynamic compliance control is applied on the base of hydraulic control inner loop and most inner loop control are the force or torque closed loop control. While the dynamic compliance control effectiveness of outer loop can be affected by the inner loop self-dynamic-compliance. Based on this problem, the dynamic compliance series composition theory of HIVC force control system as well as the analysis of its self-dynamic-compliance is proposed. And then the paper comes up with the compliance-enhanced control, which is a compound compensation control method of dynamic compliance with multiple series branches. Finally, the experiment results indicate that the control method mentioned above can enhance the dynamic compliance of HIVC force control system observably. This provides the compensation control method of inner loop dynamic compliance for the outer loop compliance control requiring the high accuracy and high robustness for the robot.

Fuzzy Modeling and Control of Wheeled Mobile Robot

  • Kang, Jin-Shik
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.3 no.1
    • /
    • pp.58-65
    • /
    • 2003
  • In this paper, a new model, which is a Takagi-Sugeno fuzzy model, for mobile robot is presented. A controller, consisting of two loops the one of which is the inner state feedback loop designed for stability and the outer loop is a PI controller designed for tracking the reference input, is suggested. Because the robot dynamics is nonlinear, it requires the controller to be insensitive to the nonlinear term. To achieve this objective, the model is developed by well known T-S fuzzy model. The design algorithm of inner state-feedback loop is regional pole-placement. In this paper, regions, for which poles of the inner state feedback loop are lie in, are formulated by LMI's. By solving these LMI's, we can obtain the state feedback gains for T-S fuzzy system. And this paper shows that the PI controller is equivalent to the state feedback and the cost function for reference tracking is equivalent to the LQ(linear quadratic) cost. By using these properties, it is also shown in this paper that the PI controller can be obtained by solving the LQ problem.

Missile two-loop acceleration autopilot design based on 𝓛1 adaptive output feedback control

  • He, Shao-Ming;Lin, De-Fu
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.15 no.1
    • /
    • pp.74-81
    • /
    • 2014
  • This article documents the design of a novel two-loop acceleration autopilot based on $\mathcal{L}_1$ adaptive output feedback control for tail-controlled missiles. The inner loop is an adaptive angle-of-attack tracking loop and the outer loop is the traditional PI controller for error compensation. A systematic low-pass filter design procedure is provided for minimum phase system and is applied to the inner loop design while the parameters of the outer loop are obtained from the multi-objective optimization problem. The effectiveness of the proposed autopilot is verified through numerical simulations under various conditions.

The Sinusoidal Ministep Drive Technique

  • Ukakimaparn, P.;Pongswatd, V.;Kummool, S.;Sriratana. W.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.466-466
    • /
    • 2000
  • This paper presents the sinusoidal current ministep technique to drive stepping motor. The stepping motor is coupling to the increment encoder to detect the position and speed of the stepping motor. The data from the encoder is decoded to sine and cosine signal and fed to the driver system. The driver system has two loops control, the inner loop and the outer loop. The inner loop is used to control the rotating of the stepping motor and the outer is used to control the speed of the motor. The rotating of the stepping motor is controlled with the sinusoidal signal. The test results of the inner loop control can control the revolution of the stepping motor is smooth and continuously with similar to the DC motor. The outer loop uses to control the speed of the stepping motor with control the DC voltages apply to the driver. The DC voltages that apply to the driver is controlled by the AC-DC converter The test results of the outer loop control, it can control the speed of motor which is provide the any load in the design.

  • PDF

인공위성용 태양전력 조절기의 병렬운전을 위한 전류제어 방식

  • Yang, Jeong-Hwan;Park, Hui-Seong;Park, Seong-U;Jang, Jin-Baek;Lee, Sang-Gon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.182.1-182.1
    • /
    • 2012
  • 태양전력 조절기는 태양전지에서 전력을 생성하여 배터리를 충전하고 인공위성의 모든 부하에 전력을 공급하는 역할을 한다. 이러한 태양전력 조절기는 신뢰성 확보와 대전류 처리를 위해 병렬운전한다. 병렬운전 시 전류가 각 태양전력 조절기에 균등하게 분배되지 않을 경우, 한 태양전력 조절기에만 과도한 전류가 흐르게 되고 해당 태양전력 조절기에 문제가 발생한다. 따라서 병렬운전 하는 각 태양전지 조절기에 전류를 균등하게 분배하기 위해 전류 제어기가 필요하다. 전류 제어 방식에는 Inner Loop방식과 Outer Loop 방식이 있다. Inner Loop방식은 전류 제어기가 태양전력 조절기의 전류를 제어하고, 전류 제어기의 기준 전압을 외부의 전압 제어기가 제어하는 방식이다. 한편, Outer Loop 방식은 전압 제어기가 태양전력 조절기의 전압을 제어하고, 전압 제어기의 기준 전압에 태양전력 조절기의 전류 정보를 더하여 전압을 제어하면서 간접적으로 전류를 제어하는 방식이다. 한편, 태양전지는 전압과 전류가 강한 비선형성 관계를 가지므로 태양전지의 동작점에 따라 태양전력 조절기의 소신호 특성이 변화하고, 이는 전류제어기 안정도에 심각한 영향을 미친다. 따라서 본 논문에서는 태양전지의 각 동작점에 관계없이 전류 제어기가 안정적으로 태양전력 조절기의 전류분배를 수행할 수 있도록 Inner Loop방식과 Outer Loop방식의 전류 제어기를 해석하고 두 방식을 비교한다.

  • PDF

Multi-Access Points Transmit Power Control Algorithm in Consideration of the Channel Estimation Error and the Multi Rate Service (채널추정 에러와 다중 전송률 서비스를 고려한 다수 개의 엑세스포인트 전송전력제어 알고리즘)

  • Oh, Changyoon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.25 no.4
    • /
    • pp.39-47
    • /
    • 2020
  • We propose a multi-access points transmit power control algorithm in consideration of the channel estimation error and the multi-rate service. In the real communication systems, the channel estimation at the receiver side is imperfect due to limited number of pilot symbol usage. Furthermore, the multi-rate service is supported. We theoretically prove the uniqueness and the convergence of the proposed algorithm in multi-rate service environment. The proposed algorithm composes of one inner loop part and one outer loop part. Simulation results show that 1) the inner loop algorithm guarantees convergence of the transmit power level and the multi-rate service, 2) the outer loop algorithm compensates for the channel estimation error.