• 제목/요약/키워드: Injection technique

Search Result 938, Processing Time 0.029 seconds

Injection Laryngoplasty (성대주입술)

  • Sun, Dong-Il
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.24 no.2
    • /
    • pp.88-95
    • /
    • 2013
  • In recent years, the application of injection laryngoplasty to a variety of laryngeal disorders has regained popularity. The technique of injection laryngoplasty has several appealing qualities including relative technical ease, low cost, and wide availability in many clinical settings. A growing number of injectable substances and injection methods have been developed. This review is intended to provide an updated discussion of indications, materials, and techniques for injection laryngoplasty.

  • PDF

Application of Intracytoplasmic Sperm Injection in Mammals

  • Li, Xiao Xia;Lee, Kyung Bon;Lee, Ji Hye;Kim, Keun Jung;Park, Kang Sun;Kim, Min Kyu
    • Reproductive and Developmental Biology
    • /
    • v.37 no.2
    • /
    • pp.85-89
    • /
    • 2013
  • For more than two decades, the intracytoplasmic sperm injection (ICSI) technique has been used as a valuable tool to provide opportunities for studying fertilization, treating human infertility, and producing transgenic animals. Not only in facilitating fertilization but also in propagating mammalian species, ICSI has enhanced the potential of assisted reproductive technologies in human. Polyspermic fertilization has been one of major problems in pig reproduction, but the ICSI helped to solve the problem, and used widely to generate transgenic piglets. Although the ICSI technique is considered to be a very useful tool in assisted reproductive technologies, including generation of transgenic animals, there are some disadvantages using the technique. In this review, we describe the ICSI technique and its application in animal production and human infertility, and discuss advantage and disadvantage of the technique in mammals.

A Case Study on Development of Automotive Interior Parts using Gas Assisted Injection Molding Process (가스사출성형을 이용한 자동차 내장부품 개발 사례에 관한 연구)

  • Kim H. S.;Lee D. K.
    • Transactions of Materials Processing
    • /
    • v.14 no.5 s.77
    • /
    • pp.452-459
    • /
    • 2005
  • Gas assisted injection molding (GAIM) is an innovative low-pressure injection molding technique that can provide numerous benefits such as reduced part warpage, excellent surface quality without sink marks, low injection pressure and greater design flexibility. However, adoptions of GAIM may cause unexpected defects since it requires many subtle design factors such as resin shot size, delay time and gas injection pressure, which wouldn't be considered in conventional injection molding process. Therefore, experiences applying GAIM should be collected and examined in order to establish design rules of the new technique. The purpose of this paper is to summarize developing cases of three automotive interior parts such as instrument panel, map pocket folding and center facia side panel so that possibilities and limitations of GAIM were examined. As a result, it is necessary to consider characteristics of GAIM at the initial stage of part design in order to obtain various advantages of the GAIM process without occurring severe defects, which would increase time and cost required to the part development.

Accuracy of Live Fluoroscopy to Detect Intravascular Injection During Lumbar Transforaminal Epidural Injections

  • Lee, Min-Hye;Yang, Kyung-Seung;Kim, Young-Hoon;Jung, Hyun-Do;Lim, Su-Jin;Moon, Dong-Eon
    • The Korean Journal of Pain
    • /
    • v.23 no.1
    • /
    • pp.18-23
    • /
    • 2010
  • Background: Complications following lumbar transforaminal epidural injection are frequently related to inadvertent vascular injection of corticosteroids. Several methods have been proposed to reduce the risk of vascular injection. The generally accepted technique during epidural steroid injection is intermittent fluoroscopy. In fact, this technique may miss vascular uptake due to rapid washout. Because of the fleeting appearance of vascular contrast patterns, live fluoroscopy is recommended during contrast injection. However, when vascular contrast patterns are overlapped by expected epidural patterns, it is hard to distinguish them even on live fluoroscopy. Methods: During 87 lumbar transforaminal epidural injections, dynamic contrast flows were observed under live fluoroscopy with using digital subtraction enhancement. Two dynamic fluoroscopy fluoroscopic images were saved from each injection. These injections were performed by five physicians with experience independently. Accuracy of live fluoroscopy was determined by comparing the interpretation of the digital subtraction fluoroscopic images. Results: Using digital subtraction guidance with contrast confirmation, the twenty cases of intravascular injection were found (the rate of incidence was 23%). There was no significant difference in incidence of intravascular injections based either on gender or diagnosis. Only five cases of intravascular injections were predicted with either flash or aspiration of blood (sensitivity = 25%). Under live fluoroscopic guidance with contrast confirmation to predict intravascular injection, twelve cases were predicted (sensitivity = 60%). Conclusions: This finding demonstrate that digital subtraction fluoroscopic imaging is superior to blood aspiration or live fluoroscopy in detecting intravascular injections with lumbar transforaminal epidural injection.

THE LEVEL OF RESIDUAL MONOMER IN INJECTION MOLDED DENTURE BASE MATERIALS

  • Lee Hyeok-Jae;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.360-368
    • /
    • 2003
  • Statement of Problem: The residual monomer of denture base materials causes hypersensitivity on oral mucosa and intereferes with the mechanical properties of the cured resin. The amount of residual monomer is influenced by materials, curing cycle, processing method, and etc. Purpose: The aim of this study was to investigate the residual methyl methacrylate(MMA) content of injection molded denture base polymer, and to compare this with the self-cured resin and the conventional compression molded heat-cured resin. Materials and Methods: Disc shaped test specimens (50mm in diameter and 3mm thick) were prepared in a conventional flasking technique with gypsum molding. One autopolymerized denture base resins (Vertex Sc. Dentimex. Netherlands) and two heat-cured denture base resins (Vertex RS. Dentimex. Netherlands, Ivocap. Ivoclar Vivadent, USA) were used. The three types of specimens were processed according to the manufacturer's instruction. After polymerization, all specimens were stored in the dark at room temperature for 7 days. There were 10 specimens in each of the test groups. 3-mm twist drills were used to obtain the resin samples and 650mg of the drilled sample were collected for each estimation. Gas chromatography (Agillent 6890 Plus Gas Chromatograph, Agillent Co, USA) was used to determine the residual MMA content of 10 test specimens of each three types of polymer. Results: The residual monomer content of injection molded denture base resins was $1.057{\pm}0.141%$. The residual monomer content of injection molded denture base resins was higher than that of compression molded heat cured resin ($0.867{\pm}0.169%$). However, there was no statistical significant difference between two groups (p>0.01). The level of residual monomer in self cured resin($3.675{\pm}0.791$) was higher than those of injection molded and compression molded heat cured resins (p<0.01). Conclusion: With respect to ISO specification pass / fail test (2.2% mass fraction) of residual monomer, injection molding technique($1.057{\pm}0.141%$) is a clinically useful and safe technique in terms of residual monomer.

Synchronous Carrier-based Pulse Width Modulation Switching Method for Vienna Rectifier

  • Park, Jin-Hyuk;Yang, SongHee;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.604-614
    • /
    • 2018
  • This paper proposes a synchronous switching technique for a Vienna rectifier that uses carrier-based pulse width modulation (CB-PWM). A three-phase Vienna rectifier, similar to a three-level T-type converter with three back-to-back switches, is used as a PWM rectifier. Conventional CB-PWM requires six independent gate signals to operate back-to-back switches. When internal switches are operated synchronously, only three independent gate signals are required, which simplifies the construction of gate driver circuits. However, with this method, total harmonic distortion of the input current is higher than that with conventional CB-PWM switching. A reactive current injection technique is proposed to improve current distortion. The performance of the proposed synchronous switching method and the effectiveness of the reactive current injection technique are verified using simulations and experiments performed with a set of Vienna rectifiers rated at 5 kW.

Analysis on the Structure of Evaporative Diesel Spray by Using PIV Technique (화상상관법을 이용한 증발 디젤분무의 구조해석)

  • Yeom, Jeong-Kuk;Chung, Sung-Sik;Ha, Jong-Yul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.6
    • /
    • pp.74-79
    • /
    • 2004
  • The effects of change in injection pressure on spray structure have been investigated in high temperature and pressure field. To analyze the structure of evaporative diesel spray is important in speculation of mixture formation process. Also emissions of diesel engines can be controlled by the analyzed results. Therefore, this study examines the evaporating spray structure by using a constant volume vessel. The injection pressure is selected as the experimental parameter, is changed from 72 MPa to 112 MPa with a high pressure injection system(ECD-U2). The PIV(Particle Image Velocimetry) technique was used to capture flow variation of the evaporative diesel spray. A study on the mixture formation process of diesel spray was executed by the results of flow analysis in this study. Consequentially the large-scale vortex flow could be found in downstream spray and the formed vortex governs the mixture formation process in diesel spray.

A Study on the Combustion Characteristic and Soot Distribution of a Common Rail Type D.I.Diesel Visualized Engine with Pilot Injection (파일럿 분사시의 커먼레일식 직분식 가시화 디젤엔진의 연소 및 Soot분포 특성에 관한 연구)

  • 이재용;한용택;이기형;이창식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.6
    • /
    • pp.37-43
    • /
    • 2003
  • The objective of this work is to investigate the effect of swirl, injection pressure and pilot injection on D.I. diesel combustion by using a transparent engine system. The test engine is equipped with common rail injection system to obtain high pressure and to control injection timing and duration. In this study, the combustion analysis and steady flow test were conducted to estimate the heat release rate from in-cylinder pressure. Soot distribution in diffusion flame according to swirl ratio, injection pressure and pilot injection was investigated by using LII technique. As the results, high injection pressure was found to shorten ignition delay as well as enhance peak pressure and heat release rate was greatly affected by injection timing and pilot injection. In addition, the results showed that the period of soot formation corresponded to the diffusion flame.

A Comparison of Two Techniques for Ultrasound-guided Caudal Injection: The Influence of the Depth of the Inserted Needle on Caudal Block

  • Doo, A Ram;Kim, Jin Wan;Lee, Ji Hye;Han, Young Jin;Son, Ji Seon
    • The Korean Journal of Pain
    • /
    • v.28 no.2
    • /
    • pp.122-128
    • /
    • 2015
  • Background: Caudal epidural injections have been commonly performed in patients with low back pain and radiculopathy. Although caudal injection has generally been accepted as a safe procedure, serious complications such as inadvertent intravascular injection and dural puncture can occur. The present prospective study was designed to investigate the influence of the depth of the inserted needle on the success rate of caudal epidural blocks. Methods: A total of 49 adults scheduled to receive caudal epidural injections were randomly divided into 2 groups: Group 1 to receive the caudal injection through a conventional method, i.e., caudal injection after advancement of the needle 1 cm into the sacral canal (n = 25), and Group 2 to receive the injection through a new method, i.e., injection right after penetrating the sacrococcygeal ligament (n = 24). Ultrasound was used to identify the sacral hiatus and to achieve accurate needle placement according to the allocated groups. Contrast dyed fluoroscopy was obtained to evaluate the epidural spread of injected materials and to monitor the possible complications. Results: The success rates of the caudal injections were 68.0% in Group 1 and 95.8% in Group 2 (P = 0.023). The incidences of intravascular injections were 24.0% in Group 1 and 0% in Group 2 (P = 0.022). No intrathecal injection was found in either of the two groups. Conclusions: The new caudal epidural injection technique tested in this study is a reliable alternative, with a higher success rate and lower risk of accidental intravascular injection than the conventional technique.

Optimization of injection molding to minimize sink index with Taguchi's Robust Design technique (다구찌의 강건설계 기법을 이용한 사출 성형품의 싱크 마크를 최소화하기 위한 사출성형 조건의 최적화)

  • Kwon, Youn Suk;Jeong, Yeong Deug
    • Design & Manufacturing
    • /
    • v.1 no.1
    • /
    • pp.17-21
    • /
    • 2007
  • In the manufacture and processing of large plastic materials, product quality is tested and verified through several techniques such as injection processing, residual stress through injection molding and shrinkage. With regards to the injection molding process, common problems such as inconsistent density is seen when different points of the product are discovered to have varying thickness levels. Sink marks in product are then evident. This occurs when there is poor molding conditions caused about by poor runner and packaging systems incorporated into the process. We designed the runner system which is possible balanced filling to cavities using CAE program $Moldflow^{TM}$ and then obtained optimal processing conditions by Taguchi's Robust Design technique.

  • PDF