• Title/Summary/Keyword: Initial electron

Search Result 677, Processing Time 0.028 seconds

Analysis of Dose Distribution According to the Initial Electron Beam of the Linear Accelerator: A Monte Carlo Study

  • Park, Hyojun;Choi, Hyun Joon;Kim, Jung-In;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.1
    • /
    • pp.10-19
    • /
    • 2018
  • Background: Monte Carlo (MC) simulation is the most accurate for calculating radiation dose distribution and determining patient dose. In MC simulations of the therapeutic accelerator, the characteristics of the initial electron must be precisely determined in order to achieve accurate simulations. However, It has been computation-, labor-, and time-intensive to predict the beam characteristics through predominantly empirical approach. The aim of this study was to analyze the relationships between electron beam parameters and dose distribution, with the goal of simplifying the MC commissioning process. Materials and Methods: The Varian Clinac 2300 IX machine was modeled with the Geant4 MC-toolkit. The percent depth dose (PDD) and lateral beam profiles were assessed according to initial electron beam parameters of mean energy, radial intensity distribution, and energy distribution. Results and Discussion: The PDD values increased on average by 4.36% when the mean energy increased from 5.6 MeV to 6.4 MeV. The PDD was also increased by 2.77% when the energy spread increased from 0 MeV to 1.019 MeV. In the lateral dose profile, increasing the beam radial width from 0 mm to 4 mm at the full width at half maximum resulted in a dose decrease of 8.42% on the average. The profile also decreased by 4.81% when the mean energy was increased from 5.6 MeV to 6.4 MeV. Of all tested parameters, electron mean energy had the greatest influence on dose distribution. The PDD and profile were calculated using parameters optimized and compared with the golden beam data. The maximum dose difference was assessed as less than 2%. Conclusion: The relationship between the initial electron and treatment beam quality investigated in this study can be used in Monte Carlo commissioning of medical linear accelerator model.

A Transmission Electron Microscopy Study of the Initial Stage of $NiSi_2$ Nucleation on the (001) Si ((001) Si에서 $NiSi_2$의 핵생성 초기 상태에 관한 투과전자현미경 연구)

  • Lee, Sang-Ho;Lee, Jeong-Yong
    • Applied Microscopy
    • /
    • v.24 no.4
    • /
    • pp.123-131
    • /
    • 1994
  • In this study the initial stage nucleation and growth of Ni silicide on (001) Si by evaporation and furnace annealing have been investigated by transmission electron microscopy. The pressure was $10^{-6}$ Torr during evaporation and annealing. And the annealing temperature to produce $NiSi_2\;was\;800^{\circ}C$. From the evaporated film, $NiSi_2$ nucleus has grown into Si substrate with an epitaxial orientation relationship. Interfaces between $NiSi_2$ and Si were A-type {111} interfaces and {100} $NiSi_2$ interfaces were also observed at the initial stage of nucleation. Ni silicide grew into Si substrate, but the nucleus partly grew into the evaporated film, with no facets, from the nuclei in the Si substrate. $NiSi_2$ nucleus with (111) habit planes was also observed.

  • PDF

Calculation of Energy Spectra for 6 MeV Electron Beam of LINAC Using MCNPX (MCNPX를 이용한 선형가속기의 6 MeV 전자선에 대한 에너지분포 계산)

  • Lee, Jeong-Ok;Jeong, Dong-Hyeok
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.224-231
    • /
    • 2006
  • The electron energy spectra for 6 MeV electron beam were calculated using a MCNPX code. The head of the linear accelerator (ML6M; Mitsubishi, Japan) was modelled for this study. The energy spectrum of the initial electron beam was assumed to be Gaussian and the mean energy was determined by evaluating the measured and calculated values of $R_{50}$ and dose profiles in air. The energy distributions for electrons and photons at the interested points in the head of the linear accelerator were calculated by appling the Initial beam parameters. The effect of contaminant photons on depth dose curves were estimated by the photon energy spectra at the end of the applicator.

  • PDF

Decomposition of Trchloroethylene/Air Mixture by Electron Beam Irradiation in a Flow Reactor (전자빔을 이용한 흐름반응기에서의 Trichloroethylene/Air 분해)

  • ;;;Tatiana Stuchinskaya
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.1
    • /
    • pp.97-104
    • /
    • 2001
  • Decomposition of trichloroethlyene(TCE) in electron beam irradiation was examined on order to obtain information on the treatment of VOC in air. Air containing vaporized TCE has been studied in a flow reactor with different reaction environments, at various initial TCE concentration and in the presence and absence of water vapor. Maximum decomposition was observed in oxygen reaction environment and the degree of decomposition was about 99% at 20kGy for 2,000ppm initial TCE. The concentration of TCE exponentially decreased with dose in air and pure oxygen. The effect of water vapor on TCE decomposition efficiency was examined. The decomposition rate of TCE in the presence of water vapor (5,600 ppm) was approximately 10% higher than that in the absence of water vapor. Dichloroacetic acid, dichloroacethyl chloride and dichloroethyl ester acid were identified as primary products of this reaction adn were decomposed and oxidized to yield CO and $CO_2$. Perchloroethylene, hexachloroethane, chloroform and carbon tetrachloride were also observed as highly chlorinat-ed by products.

  • PDF

Improvement of Alignment Accuracy in Electron Tomography

  • Jou, Hyeong-Tae;Lee, Sujeong;Kim, Han-Joon
    • Applied Microscopy
    • /
    • v.43 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • We developed an improved method for tilt series alignment with fiducial markers in electron tomography. Based on previous works regarding alignment, we adapted the Levenberg-Marquardt method to solve the nonlinear least squares problem by incorporating a new formula for the alignment model. We also suggested a new method to estimate the initial value for inversion with higher accuracy. The proposed approach was applied to geopolymers. A better alignment of the tilt series was achieved than that by IMOD S/W. The initial value estimation provided both stability and a good rate of convergence since the new method uses all marker positions, including those partly covering the tilt images.

Effect of Target Angle and Thickness on the Heel Effect and X-ray Intensity Characteristics for 70 kV X-ray Tube Target

  • Kim, Gyehong;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.272-276
    • /
    • 2016
  • To investigate the optimum x-ray tube design for the dental radiology, factors affecting x-ray beam characteristics such as tungsten target thickness and anode angle were evaluated. Another goal of the study was to addresses the anode heel effect and off-axis spectra for different target angles. MCNPX has been utilized to simulate the diagnostic x-ray tube with the aim of predicting optimum target angle and angular distribution of x-ray intensity around the x-ray target. For simulation of x-ray spectra, MCNPX was run in photon and electron using default values for PHYS:P and PHYS:E cards to enable full electron and photon transport. The x-ray tube consists of an evacuated 1 mm alumina envelope containing a tungsten anode embedded in a copper part. The envelope is encased in lead shield with an opening window. MCNPX simulations were run for x-ray tube potentials of 70 kV. A monoenergetic electron source at the distance of 2 cm from the anode surface was considered. The electron beam diameter was 0.3 mm striking on the focal spot. In this work, the optimum thickness of tungsten target was $3{\mu}m$ for the 70 kV electron potential. To determine the angle with the highest photon intensity per initial electron striking on the target, the x-ray intensity per initial electron was calculated for different tungsten target angles. The optimum anode angle based only on x-ray beam flatness was 35 degree. It should be mentioned that there is a considerable trade-off between anode angle which determines the focal spot size and geometric penumbra. The optimized thickness of a target material was calculated to maximize the x-ray intensity produced from a tungsten target materials for a 70 keV electron energy. Our results also showed that the anode angle has an influencing effect on heel effect and beam intensity across the beam.

Electron Crystallography of CaMoO4 Using High Voltage Electron Microscopy

  • Kim, Jin-Gyu;Choi, Joo-Hyoung;Jeong, Jong-Man;Kim, Young-Min;Suh, Il-Hwan;Kim, Jong-Pil;Kim, Youn-Joong
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.3
    • /
    • pp.391-396
    • /
    • 2007
  • The three-dimensional structure of an inorganic crystal, CaMoO4 (space group I 41/a, a = 5.198(69) A and c = 11.458(41) A), was determined by electron crystallography utilizing a high voltage electron microscope. An initial structure of CaMoO4 was determined with 3-D electron diffraction patterns. This structure was refined by crystallographic image processing of high resolution TEM images. X-ray crystallography of the same material was performed to evaluate the accuracy of the TEM structure determination. The cell parameters of CaMoO4 determined by electron crystallography coincide with the X-ray crystallography result to within 0.033-0.040 A, while the atomic coordinates were determined to within 0.072 A.

A Glance of Electron Tomography through 4th International Congress on Electron Tomography (International Congress on Electron Tomography에 대한 간략한 이해와 현황)

  • Rhyu, Im-Joo;Park, Seung-Nam
    • Applied Microscopy
    • /
    • v.38 no.3
    • /
    • pp.275-278
    • /
    • 2008
  • Electron tomography (ET) is an electron microscopic technique for obtaining a 3-D image from any electron microscopy specimen and its application in biomedical science has been increased thanks to development of electron microscopy and related technologies during the last decade. There are few researches on ET in Korea during this period. Although the importance of ET has been recognized recently by many researchers, initial approach to electron tomographic research is not easy for beginners. The 4th International Congress on Electron Tomography (4 ICET) was held on Nov $5{\sim}8$, 2006, at San Diego. The program dealt instrumentation, reconstruction algorithm, visualization/quantitative analysis and electron tomographic presentation of biological specimen and nano particles. 1 have summarized oral presentations and analyzed the posters presented on the meeting. Cryo-electron microscopic system was popular system for ET and followed conventional transmission electron microscopic system. Cultured cell line and tissue were most popular specimens analyzed and microorganisms including bacteria and virus also constituted important specimens. This analysis provides a current state of art in ET research and a guide line for practical application of ET and further research strategies.

Core-shell Poly(D,L-lactide-co-glycolide )/Poly(ethyl 2-cyanoacrylate) Microparticles with Doxorubicin to Reduce Initial Burst Release

  • Lee, Sang-Hyuk;Baek, Hyon-Ho;Kim, Jung-Hyun;Choi, Sung--Wook
    • Macromolecular Research
    • /
    • v.17 no.12
    • /
    • pp.1010-1014
    • /
    • 2009
  • Monodispersed microparticles with a poly(D,L-lactide-co-glycolide) (PLGA) core and a poly(ethyl 2-cyanoacrylate) (PE2CA) shell were prepared by Shirasu porous glass (SPG) membrane emulsification to reduce the initial burst release of doxorubicin (DOX). Solution mixtures with different weight ratios of PLGA polymer and E2CA monomer were permeated under pressure through an SPG membrane with $1.9\;{\mu}m$ pore size into a continuous water phase with sodium lauryl sulfate as a surfactant. Core-shell structured microparticles were formed by the mechanism of anionic interfacial polymerization of E2CA and precipitation of both polymers. The average diameter of the resulting microparticles with various PLGA:E2CA ratios ranged from 1.42 to $2.73\;{\mu}m$. The morphology and core-shell structure of the microparticles were observed by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The DOX release profiles revealed that the microparticles with an equivalent PLGA:E2CA weight ratio of 1:1 exhibited the optimal condition to reduce the initial burst of DOX. The initial release rate of DOX was dependent on the PLGA:E2CA ratio, and was minimized at a 1:1 ratio.

Ultrastructural Study on Differentiation of Plastid in Panax ginseng Root Tip (인삼(Panax ginseng) 근단의 색소본 분화에 관한 미세구조적 연구)

  • Jeong, Byung-Kap;Kim, Woo-Kap
    • Journal of Ginseng Research
    • /
    • v.16 no.1
    • /
    • pp.31-36
    • /
    • 1992
  • The ultrastructural changes and differentiation mechanism of chromoplasts and leucoplasts from Proplastids in root tip cells of Panax ginseng seedlings were studied with transmission electron microscope. Initial cells have so many proplastids with a few osmiophilic droplets and a lot of mitochon dria at early stage of germination, therefore electron density of cytoplasm is generally higher than that of the other cells just like periblem, plerome and root cap. Proplastids are observed in the initial cells, but only leucoplasts appeared in the central root cap cells. Because root cap cells are derived ultimately from initial cells, the cell organelles in the root cap cells are directly related by those of initial cells. This result postulates that leucoplast is diferentiated from proplastid, and this is the same with other's concepts. On the contrary, the precise observations of chromoplast with crystalline inclusions in the peripheral root cap cells can conclude the direct pathway of chromoplast development from proplastid. Because of the differences of these result from those of other experiments, new scheme of plastid development, direct differentiation of chromoplast from proplastid, can be postulated. And this is the originality of this research on the differentiation of plastids.

  • PDF