• 제목/요약/키워드: Infrared light source

검색결과 114건 처리시간 0.03초

Resonant inelastic X-ray scattering of tantalum double perovskite structures

  • Oh, Ju Hyun;Kim, Jung Ho;Jeong, Jung Hyun;Chang, Seo Hyoung
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1225-1229
    • /
    • 2018
  • In this paper, we investigated the electronic structures and defect states of $SrLaMgTaO_6$ (SLMTO) double perovskite structures by using resonant inelastic x-ray scattering. Recently, $Eu^{3+}$ doped SLMTO red phosphors have been vigorously investigated due to their higher red emission efficiency compared to commercial white light emitting diodes (W-LED). However, a comprehensive understanding on the electronic structures and defect states of host SLMTO compounds, which are specifically related to the W-LED and photoluminescence (PL), is far from complete. Here, we found that the PL spectra of SLMTO powder compounds sintered at a higher temperature, $1400^{\circ}C$, were weaker in the blue emission regions (at around 400 nm) and became enhanced in near infrared (NIR) regions compared to those sintered at $1200^{\circ}C$. To elucidate the difference of the PL spectra, we performed resonant inelastic x-ray spectroscopy (RIXS) at Ta L-edge. Our RIXS result implies that the microscopic origin of different PL spectra is not relevant to the Ta-related defects and oxygen vacancies.

Moving Target Position Detecting System using Dual Line CCD and Photometric Interpolation

  • Ryu, Kwang-Ryol;Kim, Young-Bin
    • Journal of information and communication convergence engineering
    • /
    • 제7권3호
    • /
    • pp.366-371
    • /
    • 2009
  • A realization for an accurate position detecting system of a moving target in two dimensional plane using dual line CCDs and photometric interpolation is presented. The system is realized that the infrared LEDs are utilized for lighting source, a target size is recognized by the scanned data from CCD owing to blocking the radiated light path by placing the target between CCD and lighting source, a coordinate on the plane is found by plane trigonometry formed by the moving target and two CCD sensors, and the former scan data is used for the coordinate iteratively and the photometric interpolation is applied to sub-pixel of scanned image. The experimental results show that the experiment results in a success rate about 3 different size targets, 3, 5 and 7mmm on the test plane $210{\times}373mm$. The moving target positioning detected success rate is 93% in 3mm target, 5mm is 95.3%, and 7mm is 95.8% respectively. The photometric interpolation is enhanced to 1.5% in comparison to be unused.

Design of the IGRINS Calibration System

  • 오희영;김강민;이성호;장비호;이상은;박수종;육인수;천무영
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.155.2-155.2
    • /
    • 2011
  • We present development of the calibration system for IGRINS (the Immersion GRating Infrared Spectrograph). We mainly use Th-Ar and U hollow cathode lamp as the spectral calibration source and telluric features can be used additionally. For the flat source, we selected a 3000K tungsten halogen lamp with 2 inch integrating sphere. From Light Tools simulation, the result flat image through calibration optics satisfied <1% flatness error requirement. We also present mechanical design of calibration box that will be attached on the IGRINS dewar. Three moving stages are designed to perform switching mechanism between all of the observing modes - target observation, flat, precision RV measurement, and spectro-polarimetric observation.

  • PDF

Open-Tube에서 Zn확산을 이용한 GaAs에의 $p^+$층 형성 (Formation of $P^+-Layer$ in GaAs Using the Open-Tube Diffusion of Zn)

  • 심규환;강진영;민석기;한철원;최인훈
    • 대한전자공학회논문지
    • /
    • 제25권8호
    • /
    • pp.959-965
    • /
    • 1988
  • Zinc diffusion characteristics and its applicabilities have been studied using an open-tube system. Thermal decomposition of arsenide(As) at gallium arsenide(GaAs) wafer surface was well inhibited by using Ga: poly-GaAs: Zn compositon as a diffusion source. Junction depth was obtained as 4.6x10**7\ulcorner exp)-1.25/kT) where activation energy of diffusion was 1.25eV. From Boltzmann-matano analysis, it could be identified that concentration dependencies of Zn diffusivity well consisted with those of kick-out model. The ideality factor of p+-n junction formed by Zn diffusion was about 1.6 and infrared light intensity was linearly varied in the range of sixty folds. It is concluded frodm these results that Zn diffuses according to kick-out model, and open-tube method is applicable to compound semiconductor devices.

  • PDF

야시조명계통 요구도 분석 (Analysis of Requirements for Night Vision Imaging System)

  • 권종광;이대열;김환우
    • 한국군사과학기술학회지
    • /
    • 제10권3호
    • /
    • pp.51-61
    • /
    • 2007
  • This paper concerns about the requirement analysis for night vision imaging system(NVIS), whose purpose is to intensify the available nighttime near infrared(IR) radiation sufficiently to be caught by the human eyes on a miniature green phosphor screen. The requirements for NVIS are NVIS radiance(NR), chromaticity, daylight legibility/readability, etc. The NR is a quantitative measure of night vision goggle (NVG) compatibility of a light source as viewed through goggles. The chromaticity is the quality of a color as determined by its purity and dominant wavelength. The daylight legibility/readability is the degree at which words are readable based on appearance and a measure of an instrument's ability to display incremental changes in its output value. In this paper, the requirements of NR, chromaticity, and daylight legibility/readability for Type I and Class B/C NVIS are analyzed. Also the rationale is shown with respect to those requirements.

섬광의 복사온도 측정 장치의 설계 및 제작 (Design and Implementation of a Radiative Temperature Measurement System for a Flash Light)

  • 진정호;한승오;양희원;박승만
    • 한국광학회지
    • /
    • 제26권1호
    • /
    • pp.30-37
    • /
    • 2015
  • 섬광의 복사온도를 측정 할 수 있는 장치를 설계하고 제작하였다. 본 논문에서는 중 원적외선 영역에서 광원의 스펙트럼 복사휘도(spectral radiance)를 측정하여 두 영역의 복사휘도 비로부터 섬광의 복사온도를 구할 수 있는 장치를 설계 및 제작하였다. 중 원적외선 영역에서 파장에 따른 복사휘도를 측정하기 위하여 광학적 대역 투과필터로 입사광을 파장에 따라 분할하고 각각의 파장으로 분할된 광을 동시에 적외선 검출기로 검출하여 입력광의 파장에 따른 복사휘도를 측정하였다. 제작된 장비로 섬광의 온도를 측정한 결과 1393K와 1455K의 온도를 얻었다. 제작된 복사온도 측정 장치는 섬광의 광원 정보를 파악하는데 중요하게 활용될 수 있으며, 섬광의 효과를 위한 M&S에 활용될 수 있다.

수종 복합레진 내의 bis-GMA와 TEGDMA의 구성비가 레진 인레이 법에 의한 부가적 열처리시 복합레진의 표면 및 내부의 중합률 변화에 미치는 영향 (CORRELATION BETWEEN BIS-GMA : TEGDMA RATIO AND DEGREE OF CONVERSION IN VARIOUS LAYERS OF COMPOSITE AFTER ADDITIONAL HEAT CURING)

  • 박성호;정찬문
    • Restorative Dentistry and Endodontics
    • /
    • 제21권2호
    • /
    • pp.642-651
    • /
    • 1996
  • The purpose of this study was to evaluate the relationship between monomer compositions and the changes in the degree of conversion in the various layers of composites after additional heat curing. Four types of composites and 3 types of inlay ovens were used in this study. Composite was placed in a 4-mm thick teflon mold, and light cured from the top for 60 seconds. Ten samples were prepared for each composite ; 5 of these were additionally heat cured in an inlay oven as the manufacturer recommended. After light curing or light and heat curing, the samples were sectioned into four parts and assigned to groups A, B, C, or D according to their distance from the light source. These sections were then thinned to 50-$70{\mu}m$, and these wafers were analyzed with a Fourier Transform Infrared Spectrometer(FI-IR) to determine the degree of conversion. A standard baseline technique was used to calculate the degree of conversion. $^{13}C$ NMR spectra of bis-GMA, TEGDMA and bis-EMA, were acquired using a Varian Gemini spectrometer operated at 200 MHz. $CDCl_3$ solvent was used for qualitative analysis. The degree of conversion was affected by bis-GMA : TEGDMA ratio but it seemed to be also affected by other factors. When the composites were heat cured, significant increases in the degree of conversion were noted throughout the samples, but the amount of increase differed between materials. Thus, clinical performance of a heat-treated composite inlay may be different depending on materials.

  • PDF

근적외선 분광을 이용한 딸기의 당도예측모델 개발 (Development of Prediction Model for Sugar Content of Strawberry Using NIR Spectroscopy)

  • 손재룡;이강진;강석원;양길모;서영욱
    • 산업식품공학
    • /
    • 제13권4호
    • /
    • pp.297-301
    • /
    • 2009
  • 본 연구에서는 딸기의 당도예측모델을 개발하기 위하여 수행하였으며, 딸기의 당도판정에 보다 적합한 조명장치를 설계하기 위해 조명의 영향을 구명하고, 딸기의 당도예측 모델을 개발하였으며, 주요연구 결과는 다음과 같다. 조명방법에 따른 당도 예측 성능을 비교한 결과 4개의 램프로 시료를 직접 조명하는 경우 $r_{SEP}$= 0.603, SEP = 0.502$^{\circ}$Bx으로 나타났으며, 광 화이버로 빛을 유인하여 국부적으로 시료에 점 조명한 경우(광 화이버 3개 사용)에는 $r_{SEP}$= 0.715, SEP = 0.433$^{\circ}$Bx으로서 후자가 더 좋은 성능을 나타내었다. 또한 램프 반사면의 금 코팅 유무에 따른 당도판정 성능시험을 실시한 결과 금 코팅된 할로겐램프를 사용한 경우 $r_{SEP}$= 0.837, SEP = 0.510$^{\circ}$Bx으로서 그렇지 않은 경우의 $r_{SEP}$= 0.756, SEP = 0.580$^{\circ}$Bx보다 양호한 결과가 나타나 금 코팅에 대한 당도판정 효과가 있는 것으로 나타났다. 딸기 당도판정을 위한 최적 회귀모델을 개발하기 위하여 PLSR과 PCR을 이용하였다. 전처리를 하지 않은 경우 $r_{SEP}$= 0.860, SEP=0.498$^{\circ}$Bx로 양호한 결과가 나타났으나, 가장 좋은 결과는 상기에서 언급된 최적의 조명상태에서 측정된 스펙트럼 데이터에 OSC 전처리를 한 경우 $r_{SEP}$= 0.891, SEP = 0.443$^{\circ}$Bx, LV=14로 가장 양호한 결과를 나타내었다. 한편, PCR을 이용한 당도 예측은 전처리를 하지 않은 경우 $r_{SEP}$= 0.845, SEP = 0.520$^{\circ}$Bx, LV=17으로서 DT 전처리에서의 $r_{SEP}$= 0.845, SEP = 0.521$^{\circ}$Bx, LV=17보다 오히려 높게 나타나 전처리에 따른 효과는 없는 것으로 나타났다.

Multi-Core Fiber Based Fiber Bragg Gratings for Ground Based Instruments

  • Min, Seong-Sik;Lindley, Emma;Leon-Saval, Sergio;Lawrence, Jon;Bland-Hawthorn, Joss
    • 천문학회보
    • /
    • 제40권1호
    • /
    • pp.53.2-53.2
    • /
    • 2015
  • Fiber Bragg gratings (FBGs) are the most compact and reliable method of suppressing atmospheric emission lines in the infrared for ground-based telescopes. It has been proved that real FBGs based filters were able to eliminate 63 bright sky lines with minimal interline losses in 2011 (GNOSIS). Inscribing FBGs on multi-core fibers offers advantages. Compared to arrays of individual SMFs, the multi-core fiber Bragg grating (MCFBG) is greatly reduced in size, resistant to damage, simple to fabricate, and easy to taper into a photonics lantern (PRAXIS). Multi-mode fibers should be used and the number of modes has to be large enough to capture a sufficient amount of light from the telescope. However, the fiber Bragg gratings can only be inscribed in the single-mode fiber. A photonic lantern bi-directionally converts multi-mode to single-mode. The number of cores in MCFBGs corresponds to the mode. For a writing system consisting of a single ultra-violet (UV) laser and phase mask, the standard writing method is insufficient to produce uniform MCFBGs due to the spatial variations of the field at each core within the fiber. Most significant technical challenges are consequences of the side-on illumination of the fiber. Firstly, the fiber cladding acts as a cylindrical lens, narrowing the incident beam as it passes through the air-cladding interface. Consequently, cores receive reduced or zero illumination, while the focusing induces variations in the power at those that are exposed. The second effect is the shadowing of the furthest cores by the cores nearest to the light source. Due to a higher refractive index of cores than the cladding, diffraction occurs at each core-cladding interface as well as cores absorb the light. As a result, any core that is located directly behind another in the beam path is underexposed or exposed to a distorted interference pattern from what phase mask originally generates. Technologies are discussed to overcome the problems and recent experimental results are presented as well as simulation results.

  • PDF

측면형 지정맥 인식기 설계 및 구현 (Design and Implementation of Side-Type Finger Vein Recognizer)

  • 김경래;최홍락;김경석
    • 한국인터넷방송통신학회논문지
    • /
    • 제21권3호
    • /
    • pp.159-168
    • /
    • 2021
  • 정보화 시대에 접어들면서 개개인의 신원을 정확하게 인식하여 인증하는 것은 정보 보호를 위해 매우 중요하기 때문에 신체를 활용한 생체인식의 활용이 점차 증가하고 있다. 그중 지정맥 인증 기술은 위조 및 복조하기 어려워 보안성과 정밀도가 높고 사용자 수용성이 용이하여 사회적 많은 관심을 받고 있다. 그러나 신원확인을 위한 알고리즘이나 주변의 빛의 환경에 따라 정확도가 떨어질 수 있다. 본 논문에서는 지정맥 측정 장치 중 활용성이 좋은 측면형 지정맥 인식기를 직접 설계하고 제작하여 높은 정확도와 인식률을 위해 DenseNet-201의 딥러닝 모델을 활용하여 인증하였으며 사용하는 적외선 광원과 주변 가시광선의 영향에 따른 지정맥 인증 기술의 성능을 시뮬레이션을 통해 분석하였다. 시뮬레이션은 전북대의 MMCBNU_6000과 직접 촬영한 지정맥 영상을 사용하고 EER을 이용하여 성능을 비교 분석한다.