• Title/Summary/Keyword: Inertial Balance

Search Result 18, Processing Time 0.023 seconds

Reliability and Validity Study of Inertial Sensor-Based Application for Static Balance Measurement

  • Park, Young Jae;Jang, Ho Young;Kim, Kwon Hoi;Hwang, Dong Ki;Lee, Suk Min
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.3
    • /
    • pp.311-320
    • /
    • 2022
  • Objective: To investigate the reliability and validity of static balance measurements using an acceleration sensor and a gyroscope sensor in smart phone inertial sensors. Design: Equivalent control group pretest-posttest. Methods: Subjects were forty five healthy adults aged twenty to fifty-years-old who had no disease that could affect the experiment. After pre-test, all participants wore a waist band with smart phone, and conducted six static balance measurements on the force plate twice for 35 seconds each. To investigate the test-retest reliability of both smart phone inertial sensors, we compared the intra-correlation coefficient (ICC 3, 1) between primary and secondary measurements with the calculated root mean scale-total data. To determine the validity of the two sensors, it was measured simultaneously with force plate, and the comparision was done by Pearson's correlation. Results: The test-retest reliability showed excellent correlation for acceleration sensor, and it also showed excellent to good correlation for gyroscope sensor(p<0.05). The concurrent validity of smartphone inertial sensors showed a mostly poor to fair correlation for tandem-stance and one-leg-stance (p<0.05) and unacceptable correlation for the other postures (p>0.05). The gyroscope sensor showed a fair correlation for most of the RMS-Total data, and the other data also showed poor to fair correlation (p<0.05). Conclusions: The result indicates that both acceleration sensor and gyroscope sensor has good reliability, and that compared to force plate, acceleration sensor has unacceptable or poor correlation, and gyroscope sensor has mostly fair correlation.

Implementation and Design of Inertial Sensor using the estimation of error coefficient method for sensing rotation

  • Lee, Cheol
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.3
    • /
    • pp.95-101
    • /
    • 2020
  • We studied the Implementation and design of inertial sensor that enables to improve performance by reduce the noise of rotor which Angle of inclination. Analyze model equation including motion equation and error, signal processing filter algorithm on high frequency bandwidth with eliminates error using estimation of error coefficient method is was designed and the prototype inertial sensor showed the pick off noise up to 0.2 mV and bias error performance of about 0.06 deg/hr by the experiments. Accordingly, we confirmed that the design of inertial sensor was valid for high rotation.

A Review on the Mechanism of Human Postural Control (인간의 자세조절 메커니즘에 대한 연구)

  • Lee, Dong-Woo
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.1
    • /
    • pp.45-61
    • /
    • 2005
  • Stance is defined as any state in which the total mass of the body is supported by the feet. In order to maintain stance, the sum of gravito-inertial forces acting on the body must be registered by equal and opposite forces at the region of contact between the organism and the support surface. Balance is controlled by applying forces to the surface of support so as to maintain the body's center of mass vertically above the feet. for a muIti-segment organism, there can be a variety of ways in which balance can be controlled, since movements of different body segments can have similar effects on the control of balance. In general, the organism tends to have a body configuration that is aligned with gravito-inertial force when there are no external forces acting on it. If any segments of the body are not aligned with gravito-inertial force vector, a torque on that segment would tend to move the body's center of mass. The maintenance of postural stability is accomplished in humans by a complex neural control system. This requires organizing integrating and acting upon visual, vestibular, and somatosensory input, providing orientation information to the postural control system. The information necessary to control and coordinate movement is provided by the visual sense of eye position with respect to the surrounding surface layout, the vestibular sense of head orientation in the gravito-inertial space, and the somatic sense of body segment position relative to one another and to the support surface. In this study, perception and action capability was examined from various points of view. The underlying assumption of the study was that the change of postural configuration could be effected by organism, environment and task goal.

Performance Evaluation of Inertial Balance for Measuring Mass in Microgravity (마이크로중력환경에서 사용 가능한 관성저울의 성능평가)

  • Jang, Hyun-Jin;Lee, Joo-Hee;Choi, Jae-Hyuk;Park, Seul-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.12
    • /
    • pp.1395-1401
    • /
    • 2014
  • In an effort to develop and implement an inertial balance with high performance, the response characteristics of a load cell, which are some of the critical parameters for optimal system design, were evaluated using a sample object of approximately 100 g under microgravity conditions. To this end, a 15-m drop-tower was used to produce microgravity conditions, and the response characteristics of the load cell were investigated in terms of the variations in the magnitude of the deceleration of the sample object, noting that the mass of a living animal should be determined in microgravity. An analysis of the ratio of the inertial forces clearly demonstrated that the average velocity of a load cell plate should be higher than 0.5 m/s to meet the design requirements.

Conceptual Design and Demonstration of Space Scale for Measuring Mass in Microgravity Environment

  • Kim, Youn-Kyu;Lee, Joo-Hee;Choi, Gi-Hyuk;Choi, Ik-Hyeon
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.4
    • /
    • pp.419-425
    • /
    • 2015
  • In this study, a new idea for developing a space scale for measuring mass in a microgravity environment was proposed by using the inertial force properties of an object to measure its mass. The space scale detected the momentum change of the specimen and reference masses by using a load-cell sensor as the force transducer based on Newton's laws of motion. In addition, the space scale calculated the specimen mass by comparing the inertial forces of the specimen and reference masses in the same acceleration field. By using this concept, a space scale with a capacity of 3 kg based on the law of momentum conservation was implemented and demonstrated under microgravity conditions onboard International Space Station (ISS) with an accuracy of ${\pm}1g$. By the performance analysis on the space scale, it was verified that an instrument with a compact size could be implemented and be quickly measured with a reasonable accuracy under microgravity conditions.

Berg Balance Scale Score Classification Study Using Inertial Sensor (관성센서를 이용한 버그균형검사 점수 분류 연구)

  • Hong, Sangpyo;Kim, Yeon-wook;Cho, WooHyeong;Joa, Kyung-Lim;Jung, Han-Young;Kim, K.S.;Lee, S.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.1
    • /
    • pp.53-62
    • /
    • 2017
  • In this paper, we present the score classification accuracy of BBS(Berg Balance Scale) which is the most commonly used balance evaluation tool using machine learning. Data acquisition was performed using the Noraxon system and an inertial sensor of Noraxon system was attached to the body in 8 locations (left and right ankle, left and right upper buttocks, left and right wrists, back, forehead). Based on the 3-axis accelerometer of the inertial sensor, the feature vector STFT(Short Time Fourier Transform) and SAM(Signal Area Magnitude) were extracted. Then, the items of the BBS were divided into static movement and dynamic movement depending on the operation characteristics, and the feature vectors were selected according to the sensor attachment positions which affect the score for each item of the BBS. Feature vectors selected for each item of BBS were classified using GMM(Gaussian Mixture Model). As a result of the accuracy calculation for 40 subjects, 55.5%, 72.2%, 87.5%, 50%, 35.1%, 62.5%, 43.3%, 58.6%, 60.7%, 33.3%, 44.8%, 89.2%, 51.8%, 85.1%, respectively.

관성센서 출력 측정을 위한 AF 변환기 교정기법

  • Kim, Jeong-Yong;Cho, Hyun-Chul;Roh, Woong-Rae;Choi, Hyung-Don;Cho, Gwang-Rae
    • Aerospace Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.117-125
    • /
    • 2005
  • Generally, the inertial navigation and guidance unit uses AF(Analog-to-Frequency) converters which convert analog signals into frequency signals to enhance a measurement accuracy of gyroscope and accelerometer outputs. The confidence level of AF converter is guaranteed by a prudential decision of calibration procedure and a performance of periodic calibration test. In this paper, we focus on the synchronous charge balance type AF converter which has a separate positive or negative current input and its calibration method is described. The calibration tests are classified into the scale factor error calibration and the bias calibration. These tests are automatically performed by the calibration program.

  • PDF

Change of Balance Ability in Subjects with Pain-Related Temporomandibular Disorders

  • Ja Young Kim;Sang Seok Yeo
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.6
    • /
    • pp.321-325
    • /
    • 2022
  • Purpose: Temporomandibular disorder (TMD) is a condition defined as pain and dysfunction of temporomandibular joints and masticatory muscles. Abnormal interconnections between temporomandibular muscles and cervical spine structures can cause the changes of postural alignment and balance ability. The aim of this study was to investigate changes in static balance ability in subjects with painrelated TMD. Methods: This study conducted on 25 subjects with TMD and 25 control subjects with no TMD. Pressure pain thresholds (PPTs) of the masseter and temporalis muscles were measured using a pressure algometer. Static balance ability was assessed during one leg standing using an Inertial Measurement Unit (IMU) sensor. During balance task, the IMU sensors measured motion and transfer movement data for center of mass (COM) motion, ankle sway and hip sway. Results: PPTs of masseter and temporalis muscles were significantly lower in the TMD group than in the control group (p<0.05). One leg standing, hip sway, and COM sway results were significantly greater in the TMD group (p<0.05), but ankle sways were not different between group. Conclusion: We suggest pain-related TMD is positively related to reduced PPTs of masticatory muscles and to static balance ability. These results should be considered together with global body posture when evaluating or treating pain-related TMD.

Analysis and Training Contents of Body Balance Ability using Range of Motion of Lumbar Spine and Center of Body Pressure (요추 관절가동범위와 신체압력중심을 이용한 신체균형능력 분석 및 훈련 콘텐츠)

  • Goo, Sejin;Kim, Dong-Yeon;Shin, Sung-Wook;Chung, Sung-Taek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.279-287
    • /
    • 2019
  • In this paper, we attempted to analyze the balance ability of the body by measuring changes in body motion and plantar pressure distribution. So we developed a program that can measure and analyze range of motion and center of body pressure using inertial measurement unit(IMU) and FSR(Force Sensing Resistor) sensor, we also produced a contents that can help improve the balance ability. The quantitative values of range of motion and center of body pressure measured by this program are visualized in real time so that the user can easily recognize the results. In addition, the contents were designed to be adjusted according to the direction of improving the balance ability by adjusting the difficulty level based on the measured balance information. This can be achieved by increasing the concentration and participation will by using visual feedback method that proceeds while watching moving objects according to the user's motion.

Dynamic Analysis Design of Balance Shaft for Reducing Engine Inertia Force and Pitching Moment (엔진 관성력과 피칭모멘트 저감을 위한 밸런스샤프트의 동역학 설계)

  • Kim, Byeong Jun;Boo, Kwang Suk;Kim, Heung Seob
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.4
    • /
    • pp.307-313
    • /
    • 2022
  • The importance of engine vibration reduction is increasing as the vehicle interior noise becomes more serious due to higher output and lighten weight trends. Recently, the balance shaft attachment has been proposed as a representative method for the engine vibration reduction. The balance shaft is a device that cancels the vibrations generated in the reciprocating motion of the piston and the conrod by using an arbitrary eccentric mass, and can improve fuel efficiency and ride comfort at the same time. This paper proposes the unbalance amount and shape of the balance shaft to induce and offset the inertia force generated by the engine structure. The proposed two-shaped balance shaft was implemented as an ADAMS multi-body dynamics model, and the reduction of the inertial force in the actual behavior was confirmed through dynamic simulation.