• Title/Summary/Keyword: Induction pump

Search Result 103, Processing Time 0.031 seconds

The Analysis of Liquid Metal Flow Characteristics in the Annular Passage of an Electromagnetic Pump

  • Kim, Chang-Eob;Jeon, Mun-Ho;Kwon, Jeong-Tae;Lim, Hyo-Jae;Lee, Suk-Won
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.270-275
    • /
    • 2010
  • An electromagnetic pump using a tubular induction motor (TLIM) has been proposed to pump liquid metal fluids. TLIM has been designed for liquid metal flow systems with a motor with a thrust force of 40~77[N]. The flow characteristics have been investigated by solving the Navier-Stokes equation, where the Lorentz force was included simply by considering it as a constant in the Navier-Stokes equation. A wood metal was chosen to simulate the liquid metal. The effect of Lorentz force on the flow rate was investigated. An experiment was conducted and its results were compared with those of the simulation. The simulation result showed an overestimation of about 17% compared with the experimental one.

Induction of Sexual Maturation in Female Eels (Anguilla japonica) Using an Osmotic Pump (Osmotic pump를 이용한 암컷 뱀장어(Anguilla japonica)의 성성숙 유도)

  • Kim, Jung-Hyun;Kim, Dae-Geun;Kim, Hyo-Won;Lee, Bae-Ik;Kim, Shin-Kwon;Jun, Je-cheon;Myeong, Jeong-In;Kim, Dae-Jung
    • Journal of Life Science
    • /
    • v.27 no.10
    • /
    • pp.1097-1103
    • /
    • 2017
  • For the artificial induction of the sexual maturation of Anguilla japonica, salmon pituitary extract (SPE) is continuously injected into females, and the eggs obtained from artificial sexual maturation are artificially fertilized with sperms and hatched. However, repeated injection of SPE in the abdominal cavity causes tremendous stress in females, which may prevent their complete sexual maturation and reduce the immune system function, ultimately resulting in death. In addition, the poor quality of the ovulated eggs can reduce the hatching and survival rate of larvae. In the present study, sexual maturation of females was induced by inserting an osmotic (OS) pump containing hormone analogs known to effectively induce sexual maturation into the abdominal cavity of female eels, and the effect of the OS pump on the induced sexual maturation was investigated. Our study results showed that the gonadosomatic index (GSI) was significantly higher in the fish subjected to SPE injection than those subjected to human chorionic gonadotropin (hCG), gonadotropin-releasing hormone analog (GnRHa), and methyl testosterone (MT) injections, either separately or in combination. In addition, a histological analysis showed that the oocytes in the SPE OS pump groups were more mature (entered the nuclear shift stage) than those in the other groups. These results suggest that an osmotic pump containing hormone analogs can be used to induce sexual maturation in female A. japonica artificially.

Analysis of Abnormal Signals for Induction Motor according to Operating Status of Fire Pumps (소방펌프의 운전상태에 따른 유도전동기의 이상 신호 분석)

  • Ku, Bonhyu;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.20-27
    • /
    • 2022
  • This article aims to develop an algorithm that detects fire pump defects by analyzing the current signals of an induction motor, which are triggered by changes in the flow rate and pressure of multistage volute pumps that are used for fire services. The operational status of the pumps was categorized into three: first, normal operation; second, a defect that is caused by a change in the current value; and third, a defect occasioned by a change in current, pressure, and flow rate. When a fire pump was in normal operation, the motor's operating current was measured between 5.06 A and 6.9 A, the flow rate was estimated at 0-0.27 m3/min, and the pressure ranged from 0 to 0.47 MPa. In the event that a defect was caused by an abnormal current value in the motor, it was attributed to the pump's adherence. Furthermore, if there was no source of water, the defect was considered to have been induced by phase-loss operation, no-load operation, or run-stop operation, with the current value of each scenario being measured at > 52.8 A, < 4.13 A, > 45.15 A, and < 3.8 A, respectively, placing its overall range between 0 and 50 A. The sources of defects were detected based on an analysis of the flow rate, pressure, and current, which represent the following causes: air inflow into the casing, inadequate suction of water, and reverse-phase operation, respectively. Each cause entailed the following values: when air seeped into the casing, the pressure was measured at 0.24 MPa irrespective of changes in the flow rate; when there was inadequate suction of water, the pressure was recorded between 0 and 0.05 MPa despite changes in the flow rate; and when the power line's reverse-phase loss was the cause of the defect, the pressure was measured at 0.33 MPa for a flow rate of 0 L/min, and a higher flow rate decreased the pressure to nearly 0 MPa. The results of this study will enable engineers to develop a pump defect detection algorithm that is based on an analysis of current, and this algorithm will facilitate the execution of a program that will control a fire pump defect detection system.

Experiments of Electromagnetic Pump using Linear Induction Motor (선형유도전동기를 이용한 전자기 펌프 실험)

  • Jeon, Mun-Ho;Kim, Jung-Hyun;Kim, Min-Seok;Kim, Chang-Eob
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.691-692
    • /
    • 2006
  • The electromagnetic pump can transfer molten metals by the electromagnetic force of LIM for molten metals, which are zinc, tin and aluminum. The speed and quantity of the flow are analyzed using magnetohydrodynamics. The molten zinc is used in the experiment and the experimental results are compared with the analysis.

  • PDF

Manufacturing of the Linear Induction EM Pump for the Liquid Sodium (액체소듐 구동용 선형유동전자펌프 제작)

  • 김희령;남호윤;황중선
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.434-437
    • /
    • 1999
  • An EM pump is used for the purpose of transporting the electrically conducting liquid sodium of the high temperature that is used as a coolant in the liquid metal reactor. In the present study, the pilot pump has been designed and manufactured for the high temperature of $600^{\circ}C$ by the equivalent circuit materials and the consideration of the materials and functions. The length and diameter of the pump are given as 84 cm and 10 cm each due to the fixed geometry of the circulation system to be installed. The characteristic of the developing pressure and efficiency is found out by using Laithewaite\`s standard design formula. It is shown that the developing pressure and efficiency are maximized at the frequency of 15 Hz from the curve. The annular channel gap of 3.95 mm is selected in the range of the reasonable hydraulic frictional loss. The components of the pump consist of the material for the high temperature. And then, the pump is manufactured to have the nominal flowrate of 40 1/min and developing Pressure of 1.3 bar.

  • PDF

A Study on the Characteristics of the Liner Electromagnetic Pump for Transferring Molten Zinc (용융아연 이송용 선형 전자기 펌프의 특성에 관한 연구)

  • Kim, S.W.;Hong, S.O.;Kim, C.E.;Shim, D.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.142-144
    • /
    • 1999
  • This work deals with an application of linear induction motor. In the process of making steel, the molten zinc is required to flow by electromagnetic force. For this purpose, the characteristics of a single sided linear induction motor are analyzed at various conditions.

  • PDF

Characteristic Analysis of a Small ALIP for the Developing of the Liquid Sodium (액체 소듐 순환 구동용 소형 환단면 선형유도전자펌프의 특성 분석)

  • Kim, Hee-Reyoung;Kim, Jong-Man;Nam, Ho-Yun;Hwang, Jong-Sun;Seo, Jang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.11a
    • /
    • pp.1-3
    • /
    • 1999
  • EM (ElectroMagnetic) pump is used for the purpose of transporting liquid sodium coolant with electrical conductivity in the LMR(Liquid Metal Reactor). (In the present study, pilot EM pump has been designed by using of equivalent circuit method which is commonly employed to analyze linear induction machines for the test of removal of residual heat. The length and diameter of the pump have fixed values of 840 mm and 101.6 mm each by taking account of geometrical size of circulation loop for the installation of EM pump. Flowrate versus developing pressure is related from Laithwaite's standard design formula and the characteristic analyses of developing force and efficiency are carried out according to change of input frequency. From the characteristic curve, input frequency of 13 Hz is determined as the design frequency. On the other hand, The annular air gap size of 6.05 mm is selected not to bring about too much hydraulic loss. Resultantly design analysis makes pump have the electrical input of 604 VA and the hydrodynamical capacity of 1.3 bars and 40 l/min.

  • PDF

Design of ALIP with Flowrate of 40 I/min for the Removal of Residual Heat (잔열 제거용 40 I/min급 환단면 선형유도전자펌프의 설계)

  • Kim, H.R.;Nam, H.Y.;Kim, Y.G.;Choi, B.H.;Kim, J.M.;Hwang, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.13-15
    • /
    • 1998
  • EM(Electro Magnetic) pump is used for the purpose of transporting liquid sodium coolant with electrical conductivity in the LMR(Liquid Metal Reactor). In the present study. pilot EM pump has been designed by using of equivalent circuit method which is commonly employed to analyze linear induction machines for the test of removal of residual heat. The length and diameter of the pump have fixed values of 840 mm and 101.6 mm each by taking account of geometrical size of circulation loop for the installation of EM pump. Flowrate versus developing pressure is related from Laithwaite's standard design formula and the characteristic analyses of developing force and efficiency are carried out according to change of input frequency. From the characteristic curve, input frequency of 13 Hz is determined as the design frequency. On the other hand, The annular air gap size of 6.05 mm is selected not to bring about too much hydraulic loss. Resultantly design analysis makes pump have the electrical input of 604 VA and the hydrodynamical capacity of 1.3 bars and 40 l/min.

  • PDF

Development of a Hydraulic Power Package Enclosed with an Electric Motor (모터 일체형 유압 파워 패키지의 개발)

  • Park, Y.H.;Lee, C.D.;Lee, J.K.
    • Journal of Power System Engineering
    • /
    • v.4 no.3
    • /
    • pp.55-61
    • /
    • 2000
  • In this study, a new design of an one-body type of an unbalanced-fixed- displacement type vane pump combined with an induction type electric motor was suggested. By the application of the new design scheme, it was possible to reduce the number of parts of the pump system and to cut down the volume of power package than that of already-used products. The case in this study enabled efficient heat transfer and electricity insulation of hydraulic fluid. Thus oil moves through the inside of the package for cooling and returns to the reservoir. Because of this design, it was difficult to measure the shaft-input torque. Therefore the package overall efficiency in the paper was evaluated with a ratio of hydraulic power and electric power.

  • PDF