• 제목/요약/키워드: Induced current

검색결과 2,675건 처리시간 0.029초

흰쥐 신경세포에서 억제성 및 흥분성 한약재가 유발한 이온전류의 특성 (Characterization of ion current induced by inhibitory and excitatory herbs in rat periaqueductal gray neuron)

  • 이충열;조선혜;서종은;한승호;조영욱;민병일;김창주
    • 대한한의학회지
    • /
    • 제19권2호
    • /
    • pp.450-467
    • /
    • 1998
  • To research the characteristics of ion currents induced by inhibitory and excitatory herbs of oriental medicine, we used nystatin-perforated patch clamp technique under voltage clamp condition in periaqueductal gray neuron dissociated from Sprauge-Dawley rat, 10-15 days old. The results are as follows. 1. Ion current induced by $10mg/m{\ell}$ of Bupleuri Radix was inhibited $59.50{\pm}4.29%$ by $10^{-4}M$ bicuculline(p>0.01) but inhibition of $10.75{\pm}4.77%$ by $10^{-4}M$ tubocurarine and $4.75{\pm}4.23%$ by $10^{-4}M$ verapamil had no statistical significance(p>0.05). So ion current induced by Bupleuri Radix revealed only GABA induced $Cl^-$ current, not acetylcholine and $Ca^{2+}$ current. 2. Ion current induced by $20mg/m{\ell}$ of Coptidis Rhizoma was inhibited $47.20{\pm}7.88%$ by $10^{-4}M$ bicuculline(p<0.01) but $3.20{\pm}2.33%$ inhibition by $10^{-4}M$ tubocurarine and $1.00{\pm}1.00%$ inhibition by $10^{-4}M$ verapamil had no significance(p>0.05). So ion current induced by Coptidis Rhizoma revealed only GABA induced $Cl^-$ current, not acetylcholine and $Ca^{2+}$ current. 3. Ion current induced by $20mg/m{\ell}$ of Ecliptae Herba was inhibited $55.00{\pm}4.92%$ by $10^{-4}M$ bicuculline (p<0.01), and also inhibited $15.00{\pm}4.26%$ by $10^{-4}M$ tubocurarine(p<0.05), but inhibition of $6.00{\pm}3.03%$ by $10^{-4}M$ verapamil had no significance(p>0.05). So ion current induced by Ecliptae Herba showed GABA activated $Cl^-$ current and acetylcholine activated cation current, not $Ca^{2+}$ current 4. Ion current induced by $5mg/m{\ell}$ of Liriopis Tuber was inhibited $15.20{\pm}4.57%$ by $10^{-4}M$ bicuculline<0.05) and also inhibited $14.00{\pm}3.00%$ by $10^{-4}M$ tubocurarine(p<0.05), but inhibition of $5.20{\pm}4.80%$ by $10^{-4}M$ verapamil had no significance(p>0.05). So ion current induced by Liriopis Tuber showed GABA. activated $Cl^-$ current and acetylcholine activated cation current, not $Ca^{2+}$ current. 5. Ion current induced by $5mg/m{\ell}$ of Aconiti Tuber was inhibited $97.00{\pm}1.34%$ by $10^{-4}M$ bicuculline(p<0.01), $80.00{\pm}9.83%$ by $10^{-4}M$ tubocurarine(p<0.01), and $24.00{\pm}6.18%$ by $10^{-4}M$ verapamil(p<0.05). So ion current induced by Aconiti Tuber revealed GABA activated $Cl^-$ current and acetylcholine activated cation current and $Ca^{2+}$ current. 6. Ion current induced by $10mg/m{\ell}$ of Zingiberis Rhizoma was inhibited $33.00{\pm}7.43%$ by $10^{-4}$ bicuculline(p<0.05), $10.20{\pm}1.83%$ by $10-^{-4}M$ tubocurarine(p<0.01), and $14.00{\pm}2.16%$ by $10^{-4}M$ verapamil(p<0.01) So ion current induced by Zingiberis Rhizoma revealed GABA activated $Cl^-$ current and acetylcholine activated cation outtent and $Ca^{2+}$ current. 7. Ion current induced by $10mg/m{\ell}$ of Boshniakiae Herba was inhibited $65.00{\pm}13.75%$ by $10^{-4}M$ bicuculline(p<0.05), $38.00{\pm}9.24%$ by $10^{-4}M$ tubocurarine(p<0.05), and $33.25{\pm}7.42%$ by $10^{-4}M$ verapamiHp<0.05). So ion current induced by Bpshniakiae Herba revealed GABA activated $Cl^-$ current and acetylcholine activated cation current and $Ca^{2+}$ current. These results suggest that a point of difference between inhibitory and excitatory herbs is existence of$Ca^{2+}$ current.

  • PDF

실리콘 산화막의 전류 특성 (Current Characteristics in the Silicon Oxides)

  • 강창수;이재학
    • 한국전기전자재료학회논문지
    • /
    • 제29권10호
    • /
    • pp.595-600
    • /
    • 2016
  • In this paper, the oxide currents of thin silicon oxides is investigated. The oxide currents associated with the on time of applied voltage were used to measure the distribution of voltage stress induced traps in thin silicon oxide films. The stress induced leakage currents were due to the charging and discharging of traps generated by stress voltage in the silicon oxides. The stress induced leakage current will affect data retention in memory devices. The oxide current for the thickness dependence of stress current and stress induced leakage currents has been measured in oxides with thicknesses between $109{\AA}$, $190{\AA}$, $387{\AA}$, and $818{\AA}$ which have the gate area $10^{-3}cm^2$. The oxide currents will affect data retention and the stress current, stress induced leakage current is used to estimate to fundamental limitations on oxide thicknesses.

플래시 EEPROM 응용을 위한 산화막 특성 (The Oxide Characteristics in Flash EEPROM Applications)

  • 강창수;김동진;강기성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.855-858
    • /
    • 2001
  • The stress induced leakage currents of thin silicon oxides is investigated in the VLSI implementation of a self learning neural network integrated circuits using a linearity synapse transistor. The channel current for the thickness dependence of stress current, transient current, and stress induced leakage currents has been measured in oxides with thicknesses between 41 ${\AA}$, 86${\AA}$, which have the channel width ${\times}$ length 10 ${\times}$1${\mu}$m, 10 ${\times}$0.3${\mu}$m respectively. The stress induced leakage currents will affect data retention in synapse transistors and the stress current, transient current is used to estimate to fundamental limitations on oxide thicknesses. The synapse transistor made by thin silicon oxides has represented the neural states and the manipulation which gaves unipolar weights. The weight value of synapse transistor was caused by the bias conditions. Excitatory state and inhitory state according to weighted values affected the channel current. The stress induced leakage currents affected excitatory state and inhitory state.

  • PDF

파랑에 의한 연안류의 수치모델에 관한 연구 (A Study on the Numerical Models of Wave induced Currents)

  • 이정만;김재중;박정철
    • 한국해양공학회지
    • /
    • 제12권3호통권29호
    • /
    • pp.75-85
    • /
    • 1998
  • A finite difference model for predicting time-dependent, wave-induced nearshore current is studied. The model includes wave refraction, wave-current interaction, bottom friction and wind effect. This model iteratively solved the linear the linear set of conservation of both mass and momentum, which were time averaged (over one wave period) and depth integrated, for mean velocities and free surface displacement. Numerical simulations of nearshore current under oblique wave attack, and for wave and wind induced current on a longshore periodic beach are carried out. Longshore velocities tend to zero in some distances outside the breaker line. And the peak velocity is shifted shoreward at the breaker line. The results represent the general characteristics of the nearshore current induced by wave.

  • PDF

SILC of Silicon Oxides

  • 강창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.428-431
    • /
    • 2003
  • In this paper, the stress induced leakage currents of thin silicon oxides is investigated in the ULSI implementation with nano structure transistors. The stress and transient currents associated with the on and off time of applied voltage were used to measure the distribution of high voltage stress induced traps in thin silicon oxide films. The stress and transient currents were due to the charging and discharging of traps generated by high stress voltage in the silicon oxides. The transient current was caused by the tunnel charging and discharging of the stress generated traps nearby two interfaces. The stress induced leakage current will affect data retention in electrically erasable programmable read only memories. The oxide current for the thickness dependence of stress current, transient current, and stress induced leakage currents has been measured in oxides with thicknesses between $113.4{\AA}$ and $814{\AA}$, which have the gate area 10-3cm2. The stress induced leakage currents will affect data retention and the stress current, transient current is used to estimate to fundamental limitations on oxide thicknesses.

  • PDF

The Trap Characteristics of SILC in Silicon Oxide for SoC

  • Kang C. S.
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 ICEIC The International Conference on Electronics Informations and Communications
    • /
    • pp.209-212
    • /
    • 2004
  • In this paper, The stress induced leakage currents of thin silicon oxides is investigated in the nano scale structure implementation for Soc. The stress and transient currents associated with the on and off time of applied voltage were used to measure the distribution of high voltage stress induced traps in thin silicon oxide films. The stress and transient currents were due to the charging and discharging of traps generated by high stress voltage in the silicon oxides. The channel current for the thickness dependence of stress current, transient current, and stress induced leakage currents has been measured in oxides with thicknesses between $41\square\;and\;113.4\square,$ which have the channel width x length 10x1um, respectively. The stress induced leakage currents will affect data retention and the stress current, transient current is used to estimate to fundamental limitations on oxide thicknesses. The weight value of synapse transistor was caused by the bias conditions. Excitatory state and inhitory state according to weighted values affected the channel current. The stress induced leakage currents affected excitatory state and inhitory state.

  • PDF

Installation of Induced Current Measurement Systems in Substations and Analysis of GIC Data during Geomagnetic Storms

  • Choi, Kyu-Cheol;Park, Mi-Young;Ryu, Youngsoo;Hong, Youngsu;Yi, Jong-Hyuk;Park, Sung-Won;Kim, Jae-Hun
    • Journal of Astronomy and Space Sciences
    • /
    • 제32권4호
    • /
    • pp.427-434
    • /
    • 2015
  • Coronal Mass Ejections (CME), which originate from active regions of the Sun's surface, e.g., sunspots, result in geomagnetic storms on Earth. The variation of the Earth's geomagnetic field during such storms induces surface currents that could cause breakdowns in electricity power grids. Hence, it is essential to both monitor Geomagnetically Induced Currents (GICs) in real time and analyze previous GIC data. In 2012, in order to monitor the variation of GICs, the Korean Space Weather Center (KSWC) installed an induced current measurement system at SINGAPYEONG Substation, which is equipped with 765 kV extra-high-voltage transformers. Furthermore, in 2014, two induced current measurement systems were installed on the 345 kV high-voltage transformers at the MIGEUM and SINPOCHEON substations. This paper reports the installation process of the induced current measurement systems at these three substations. Furthermore, it presents the results of both an analysis performed using GIC data measured at the SINGAPYEONG Substation during periods of geomagnetic storms from July 2013 through April 2015 and the comparison between the obtained GIC data and magnetic field variation (dH/dt) data measured at the Icheon geomagnetic observatory.

요실금 치료용 자기 자극기의 자속밀도 및 유도전류 측정 (Measurement of Magnetic Flux and Induced Current in Magnetic Stimulation for Urinary Incontinence Treatment)

  • 한병희;최경무;조민형;이수열
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권4호
    • /
    • pp.318-326
    • /
    • 2009
  • A simple method for measuring magnetic flux and induced current in magnetic nerve stimulation for urinary incontinence treatment is proposed. Unlike electric nerve stimulation, direct measurement of the induced current in magnetic nerve stimulation is impossible. Since induced currents stimulate nerves or muscles in magnetic nerve stimulation, measuring induced current is very important in validating stimulation efficacy and securing safety. The magnetic flux measuring system is composed of 6 layers with pick-up coils of 7 by 7 in each layer, and the induced current measuring system is composed of 6 layers with 7 concentric circular coils in each layer. The proposed method can be used in the design or performance test of a magnetic nerve stimulator for many clinical applications such as urinary incontinence treatment, activation of peripheral nerves, and transcranial magnetic stimulation.

축소모델을 이용한 22.9kV-Y 배전선로의 유도뢰 분석 (Analysis on Induced Lightning of a 22.9kV-Y Distribution Line Using a Reduced Model)

  • 김점식;김도영;박용범;권신원;길경석
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.434-439
    • /
    • 2010
  • This study fabricated a simulation facility which reduced the structure of a current distribution line to 50:1 in order to analyze the induced lightning shielding effect of a 22.9kV-Y distribution line according to ground resistance capacity, grounding locations, etc. When installing an overhead ground wire, the standard for grounding a distribution line with a current of 22.9kV-Y requires that ground resistance in common use with the neutral line be maintained less than $50\Omega$every 200m span. The reduced line for simulation had 7 electric poles and induced lightning was applied to the ground plane 2m apart from the line in a direction perpendicular to it using an impulse generator. If induced voltage occurred in the line and induced current flowed through the line due to the applied current, the induced voltage and current of the 'A' phase were measured respectively using an oscilloscope. When all 7 electric poles were grounded with a ground resistance of less than $50\Omega$ respectively, the combined resistance of the line was $7.4\Omega$. When an average current of 230A was applied, the average induced voltage and current measured were 1,052V and 13.8A, respectively. Under the same conditions, when the number of grounding locations was reduced, the combined resistance as well as induced voltage and current showed a tendency to increase. When all 7 electric poles were grounded with a ground resistance of less than $100\Omega$, the combined resistance of the line was $14.9\Omega$. When an average current of 236A was applied, the average induced voltage and current of the 'A' phase calculated were 1,068V and 15.6A, respectively. That is, in this case, only the combined resistance was greater than when all 7 electrical poles were grounded, and the induced voltage and current were reduced. Therefore, it is thought that even though ground resistance is slightly higher under a construction environment with the same conditions, it is advantageous to ground all electric poles to ensure system safety.

송변전 설비주변에서의 자기장에 의한 인체에의 유도 전류 계산 (The Calculation of Induced Current at the Human Body due to Magnetic Field around Power System Equipment)

  • 한인수;박종근;명성호;이병윤;김응식;민석원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1755-1757
    • /
    • 1997
  • In this paper, a current calculation method based on Kirchhof's Current Law(KCL) and Kirchhof's Voltage Law(KVL) which is necessary to calculate magnetic fields and induced current around the human body is proposed in this paper. Using this method, we can solve the current values of the finite lines comprising the power system equipment. In the assumption that the current values induced in the human body are same, we calculate the induced current values.

  • PDF