• Title/Summary/Keyword: Indoor-air

Search Result 2,362, Processing Time 0.026 seconds

PM10 and Associated Trace Elements in the Subway Cabin of Daejeon by Instrumental Neutron Activation Analysis (기기 중성자방사화 분석을 이용한 대전 지하철 객차 내 PM10과 미량성분의 특성)

  • Jeong, Jin Hee;Lim, Jong Myoung;Lee, Jin-Hong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.8
    • /
    • pp.459-467
    • /
    • 2016
  • In order to assess the pollution status and distribution characteristics of PM and PM-bound species, PM10 samples were collected using mini-volume air sampler at the subway cabin in Daejeon city. Measurements of about 24 elements including toxic metals (e.g., As, Cr, Mn, V, Zn) in PM10 were made by instrumental neutron activation analysis and X-ray fluorescence. The average PM10 concentration was $59.3{\pm}14.5{\mu}g/m^3$ in the subway cabin with a range of 42.2 to $97.4{\mu}g/m^3$, while the associated elemental concentrations were varied in the range of $10^{-3}$ to $10^5ng/m^3$. It was found that the concentration of Fe ($12.5{\mu}g/m^3$) was substantially higher than any other element. The Fe concentration was apportioned by about 20% of the PM10 concentration. The results of factor analysis indicate that there are no more than six sources in the cabin (e.g., brake-nonferrous metal particle, resuspended rail dust, fuel combustion, vehicle exhaust, black carbon, Cr-related).

Levels and Related Factors of Airborne Fungi in Microbial and Chemistry Laboratories in Universities (일부 대학교 미생물실험실 및 화학실험실에서의 진균 분포 및 관련인자)

  • Hwang, Sung-Ho;Jo, Hyun-Woo;Park, Dong-Uk;Yoon, Chung-Sik;Ryu, Kyong-Nam;Ha, Kwon-Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • The purpose of this study is to assess the level of fungi concentration in the university laboratories in Seoul, Korea, and to investigate factors contributing to these concentrations. The samples were taken from three spots in each laboratory; the top of sink, the center of laboratory, and the front of ventilation system, i.e fume hood at the chemical laboratory and clean bench/biosafety cabinet at the microbial laboratory. Air samples were collected using the single-stage Anderson sampler (Quick Take 30) at a flow rate of 28.3 l/min for 5 min on nutrient media in Petri-dishes located on the impactor. Fifty-two air samples were collected from 19 different laboratories (13 microbiology laboratories, 6 chemistry laboratories) in the university, and concentrations of airborne fungi showed no significant difference (p>0.05) between microbiology and chemistry laboratory, and also no significant difference at three locations (sink, center, front of ventilation system) in microbiology and chemistry laboratories. Average concentrations of fungi in 19 laboratories ranged from 7 to 459 cfu/$m^3$, with an overall Geometric Mean of 52 cfu/$m^3$. Airborne fungi concentrations of 6 samples (12 %) exceeded 150 cfu/$m^3$, the guideline of WHO. The ratios of Indoor/Outdoor for airborne fungi ranged from 0.2 to 4.8 (mean = 1.6). Related factors were measured such as relative humidity, temperature, and laboratory area. Temperature and laboratory area showed no significant relations to concentrations of airborne fungi except for relative humidity in the laboratory Concentrations of fungi were significant different (p<0.01) between rainy or cloudy and sunny. However, there was no significant difference between general ventilation and nongeneral ventilation.

Relationship between Endotoxin Level of in Swine Farm Dust and Cellular Immunity of Husbandry Workers (돈사 분진 함유 내독소 수준과 축사 작업자들의 세포면역력간 상관성 분석)

  • Kim, Hyoung Ah;Kim, Ji Youn;Shin, Kyeong Min;Jo, Ji Hoon;Roque, Katharine;Jo, Gwang Ho;Heo, Yong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.4
    • /
    • pp.393-401
    • /
    • 2013
  • Objectives: Endotoxins in dust generated in occupational settings is known to contribute to the occurrence of respiratory illness among workers. The relationship between the level of endotoxins in total dust or respirable particulates collected from swine farms and immunological markers related with respiratory allergy was evaluated among swine husbandry workers. Materials and Methods: Peripheral blood samples were collected from ten workers at ten swine farms at Gyeonggi province, Korea. Peripheral mononuclear cells were stimulated with phorbol 12-myristate 13-acetate and ionomycin for 48 hours. The levels of various cytokines produced at culture supernatants were determined using a commercially available ELISA kit. The concentration of particulate matter($PM_{10}$) in the indoor air of the swine farms was evaluated using a PVC membrane filter and mini volume air sampler, and endotoxin levels in the dust were measured by Limulus Amebocyte Lysate Kinetic QCL method. Results: Levels of endotoxins in the total dust were categorized into high(geometric mean: $109.35EU/m^3$) and low concentrations (geometric mean: $0.95EU/m^3$) for five swine farms. Interleukin-4 levels were higher in the high endotoxin group than in the low endotoxin group, while interferon-${\gamma}$ levels were lower in the high endotoxin group than in the low endotoxin group. The ratio (interferon-${\gamma}$ to interleukin-4), indicating immunologic skewedness against allergic reactivities, was lower in the high endotoxin group($1.15{\pm}0.60$) than the low endotoxin group($3.09{\pm}2.38$). In addition, the level of interleukin-13, another cytokine contributing to the occurrence of allergic responses, was significantly higher in the at the high endotoxin group($1.12{\pm}0.37ng/m{\ell}$) than in the low endotoxin group($0.37{\pm}0.04ng/m{\ell}$). Hematologic assessment showed significantly lower cellularity in the number of total leukocytes, neutrophils, and eosinophils in the high endotoxin group than in the low endotoxin group. Conclusions: Even though a sufficient number of swine workers and farms were not investigated, this study generlly suggests that the immunological function of swine farm workers exposed to high levels of endotoxin could be modulated toward allergic reactivities.

Emissions of Odor, Ammonia, Hydrogen Sulfide, and Volatile Organic Compounds from Shallow-Pit Pig Nursery Rooms

  • Kafle, Gopi Krishna;Chen, Lide
    • Journal of Biosystems Engineering
    • /
    • v.39 no.2
    • /
    • pp.76-86
    • /
    • 2014
  • Purpose: The objective of this study was to measure emissions of gases (ammonia ($NH_3$), hydrogen sulfide ($H_2S$) and carbon dioxide ($CO_2$)), volatile organic compounds (VOC) and odor from two shallow pit pig nursery rooms. Gas and odor reduction practices for swine operations based on the literature were also discussed. Methods: This study was conducted for 60 days at a commercial swine nursery facility which consisted of four identical rooms with mechanical ventilations. Two rooms (room 1 (R1) and room 2 (R2)) with different pig numbers and ventilation rates were used in this study. The pig manure from both the R1 and R2 were characterized. Indoor/outdoor temperatures, ventilation rates/duration, $NH_3$, $H_2S$, $CO_2$, and VOC concentrations of the ventilation air were measured periodically (3-5 times/week). Odor concentrations of the ventilations were measured two times on two days. Three different types of gas and odor reduction practices (diet control, chemical method, and biological method) were discussed in this study. Results: The volatile solids to total solids ratio (VS/TS) and crude protein (CP) value of pig manure indicated the pig manure had high potential for gas and odor emissions. The $NH_3$, $H_2S$, $CO_2$ and VOC concentrations were measured in the ranges of 1.0-13.3, 0.1-5.7, 1600-3000 and 0.0-1.83 ppm, respectively. The $NH_3$ concentrations were found significantly higher than $H_2S$ concentrations for both rooms. The odor concentrations were measured in the range of $2853-4432OU_E/m^3$. There was significant difference in odor concentrations between the two rooms which was due to difference in pig numbers and ventilation duration. The literature studies showed that simultaneous use of dietary control and biofiltration practices will be more effective and environmentally friendly for gas and odor reductions from pig barns. Conclusions: The gas and odor concentrations measured in the ventilation air from the pig rooms indicate an acute need for using gas and odor mitigation technologies. Adopting diet control and biofiltration practices simultaneously could be the best option for mitigating gas and odor emissions from pig barns.

Source Proximity and Meteorological Effects on Residential Ambient Concentrations of PM2.5, Organic Carbon, Elemental Carbon, and p-PAHs in Houston and Los Angeles, USA

  • Kwon, Jaymin;Weisel, Clifford P.;Morandi, Maria T.;Stock, Thomas H.;Turpin, Barbara
    • Journal of Environmental Science International
    • /
    • v.25 no.10
    • /
    • pp.1349-1368
    • /
    • 2016
  • Concentrations of fine particulate matter ($PM_{2.5}$) and several of its particle constituents measured outside homes in Houston, Texas, and Los Angeles, California, were characterized using multiple regression analysis with proximity to point and mobile sources and meteorological factors as the independent variables. $PM_{2.5}$ mass and the concentrations of organic carbon (OC), elemental carbon (EC), benzo-[a]-pyrene (BaP), perylene (Per), benzo-[g,h,i]-perylene (BghiP), and coronene (Cor) were examined. Negative associations of wind speed with concentrations demonstrated the effect of dilution by high wind speed. Atmospheric stability increase was associated with concentration increase. Petrochemical source proximity was included in the EC model in Houston. Area source proximity was not selected for any of the $PM_{2.5}$ constituents' regression models. When the median values of the meteorological factors were used and the proximity to sources varied, the air concentrations calculated using the models for the eleven $PM_{2.5}$ constituents outside the homes closest to influential highways were 1.5-15.8 fold higher than those outside homes furthest from the highway emission sources. When the median distance to the sources was used in the models, the concentrations of the $PM_{2.5}$ constituents varied 2 to 82 fold, as the meteorological conditions varied over the observed range. We found different relationships between the two urban areas, illustrating the unique nature of urban sources and suggesting that localized sources need to be evaluated carefully to understand their potential contributions to $PM_{2.5}$ mass and its particle constituents concentrations near residences, which influence baseline indoor air concentrations and personal exposures. The results of this study could assist in the appropriate design of monitoring networks for community-level sampling and help improve the accuracy of exposure models linking emission sources with estimated pollutant concentrations at the residential level.

Correlation between Allergic Rhinitis Prevalence and Immune Responses of Children in Ulsan: A Case-control Study (울산지역 초등학생의 알레르기비염 유병과 면역반응과의 상관성: 환자-대조군 연구)

  • Lee, Jiho;Oh, Inbo;Kim, Ahra;Kim, Minho;Sim, Chang sun;Kim, Yangho
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.4
    • /
    • pp.249-258
    • /
    • 2015
  • Objectives: This study aims to investigate the correlations between the prevalence of allergic rhinitis (AR) and cytokines among elementary school children in an industrial city, Ulsan, South Korea, and to identify major environmental risk factors associated with AR prevalence. Methods: We conducted a case-control study in June 2009 and February 2010 in order to evaluate the relationship between AR and related cytokines. Data on physician-treated prevalence over the past 12 months and potential risk factors for AR were compiled through a questionnaire from a survey of 339 schoolchildren living in different urban environments. Logistic regression analysis was carried out with propensity score matched data (n=180) to assess the influences of cytokines (IL-13, IL-33, IL-4 and IL-5) on AR prevalence and to determine which environmental factors affected AR. Results: In univariate analysis, the AR prevalence was influenced by family history of AR (mother and siblings), environmental factors (odor condition and irritated symptoms of air pollution), and indoor allergens (D. farinae and D. pteronyssinus). The t-test demonstrated that eosinophils, Immunoglobulin E (IgE), and interleukins (IL-13 and IL-5) were statistically significantly different according to treatment of allergic rhinitis over the preceeding 12 months. The results of the multiple logistic regression analysis showed that a statistically significant association between several factors (such as irritated symptoms of air pollution (OR 4.075, CI 1.735-9.568), IL-13 (OR 0.825, CI 0.734-0.928), odor condition (OR 2.409, CI 0.908-6.389), and AR history of siblings (OR 2.217, CI 0.999-4.921)) and the prevalence of AR was found after adjusting for confounders. Conclusion: These results suggest that AR prevalence is significantly associated with cytokine level, genetic background, and outdoor environmental factors. Although living in a polluted area and genetic background can contribute to an increased risk of childhood AR, cytokine level should be considered as an important factor in the treatment of AR in the last 12 months.

Two Way Set Temperature Control Impact Study on Ground Coupled Heat Pump System Energy Saving (양방향 설정온도 제어에 따른 지중연계 히트펌프 시스템의 에너지 절감량 평가 연구)

  • Kang, Eun-Chul;Lee, Euy-Joon;Min, Kyong-Chon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.10 no.2
    • /
    • pp.7-12
    • /
    • 2014
  • Government has recently restricted heating and cooling set temperatures for the commercial and public buildings due to increasing national energy consumption. The goal of this paper is to visualize a future two way indoor set temperature control impact on building energy consumption by using TRNSYS simulation modeling. The building was modelled based on the twin test cell with the same dimension. Air source ground coupled heat pump performance data has been used for modeling by TRNSYS 17. Daejeon weather data has been used from Korea Solar Energy Society. The heating set temperature in the reference room is $24^{\circ}C$ as well as the target room set temperature are $23^{\circ}C$, $22^{\circ}C$, $21^{\circ}C$ and $20^{\circ}C$. The cooling set temperature of the reference room is also $24^{\circ}C$ as well as the target room set temperature of $25^{\circ}C$, $26^{\circ}C$, $27^{\circ}C$ and $28^{\circ}C$. For the air source heat pump system, heating season energy consumption is $35.52kWh/m^2y$ in the reference room. But the heating energy consumption in the target room is reduced to 7.5% whenever the set temperature decreased every $1^{\circ}C$. The cooling energy consumption in the reference room is $4.57kWh/m^2y$. On the other hand, the energy consumption in the target room is reduced to 22% whenever the set temperature increased every $1^{\circ}C$ by two way controller. For the geothermal heat pump system, heating energy consumption in the reference room is reduced to 20.7%. The target room heating energy consumption is reduced to 32.6% when the set temperature is $22^{\circ}C$. The energy consumption in the target room is reduced to 59.5% when the set temperature is $26^{\circ}C$.

Analysis of Microclimate and Conservation Environment of the Stone Buddha and Shrine in Unjusa Temple, Hwasun, Korea (화순 운주사 석조불감의 보존환경 및 미기상 분석)

  • Park, Sung-Mi;Lee, Chan-Hee;Lee, Myeong-Seong;Kim, Sa-Dug
    • Economic and Environmental Geology
    • /
    • v.42 no.1
    • /
    • pp.73-84
    • /
    • 2009
  • The stone Buddha and Shrine of Unjusa temple (Korean Treasure No. 797) at Hwasun formed in Koryo Dynasty is unique style which faces each other the back parts of south and north within the stone Shrine. The stone Buddha and Shrine is highly evaluated in historical, artistic and academic respects. But, the stone properties have been exposed in the open system various aspects of degradations weathered for a long time without specific protective facilities. To inquire into relative deterioration and environmental factor, air temperature and relative humidity of the stone Buddha and Shrine were monitored for a year of the indoor and outdoor, respectively. As a result, the temperature shows increase and decrease according to the seasons in the tendency to clear. While the relative humidity is high to keep all four seasons. Highly relative humidity environment induces dew condensation on the interior of stone Buddha and Shrine. The dew condensation is recorded at the spring, summer and winter season. The summer season is double the total of spring and winter season. In the case of summer, dew condensation is long time continued due to high temperature and relative humidity that is kept by more than nearly 100%. There is progress towards chemical weathering throughout dissolve rock properties and alteration on the rock surface. In the case of winter, dew condensation is not kept for a long time as summer. In the winter, which showing a below zero may add physical weathering throughout moisture that happen by dew condensation to repeat freezing and thawing. Therefore, the reduction plan of the relative humidity effect on dew condensation should be prepared.

The Realization on GAS Sensor Module for Inteligent Wireless Communication (지능형 무선통신용 가스 센서 모듈 구현)

  • Kim, Hyo-Chan;Weon, Young-Su;Cho, Hyung-Rae
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.6
    • /
    • pp.123-132
    • /
    • 2012
  • Gas sensors has been used very differently that depending on following purposes; Automotive (exhaust gas, fuel mixture gas, oxygen, particulates), agriculture / food industry (fresh, stored, CO2, humidity, NH3, nitrogen oxide gas, organic gas, toxic gas emitted from pesticides and insecticides), industrial / medical (chemical gas, hydrogen, oxygen and toxic gases), military (chemical weapon), environmental measurements (CO and other air pollution consisting of sulfur and nitrogen gas), residential (LNG, LPG, butane, indoor air, humidity). The types of industrial toxic substances are known about 700 species and many of these exist in gaseous form under normal conditions. he multi-gas detection sensors will be developed for casualties that detect the most important and find easy three kinds of gases in marine plant; carbon dioxide(CO2), carbon(CO), ammonia(NH3). Package block consists of gas sensing device minor ingredient, rf front end, zigbee chip. Develope interworking technology between the sensor and zigbee chip inside a package. Conduct a performance test through test jig about prototype zigbee sensor module with rf output power and unwanted emission test. This research task available early address when poisonous gas leaked from large industrial site and contribution for workers' safety at the enclosed space.

Analysis of Heat Emission from Hot Water Pipe for Greenhouse Heating System Design (온실 난방시스템 설계를 위한 온수난방배관의 방열량 분석)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.3
    • /
    • pp.204-211
    • /
    • 2019
  • The purpose of this study is to provide basic data for setting environmental design standards for domestic greenhouses. We conducted experiments on thermal environment measurement at two commercial greenhouses where hot water heating system is adopted. We analyzed heat transfer characteristics of hot water heating pipes and heat emission per unit length of heating pipes was presented. The average air temperature in two greenhouses was controlled to $16.3^{\circ}C$ and $14.6^{\circ}C$ during the experiment, respectively. The average water temperature in heating pipes was $52.3^{\circ}C$ and $45.0^{\circ}C$, respectively. Experimental results showed that natural convection heat transfer coefficient of heating pipe surface was in the range of $5.71{\sim}7.49W/m^2^{\circ}C$. When the flow rate in heating pipe was 0.5m/s or more, temperature difference between hot water and pipe surface was not large. Based on this, overall heat transfer coefficient of heating pipe was derived as form of laminar natural convection heat transfer coefficient in the horizontal cylinder. By modifying the equation of overall heat transfer coefficient, a formula for calculating the heat emission per unit length of hot water heating pipe was developed, which uses pipe size and temperature difference between hot water and indoor air as input variables. The results of this study were compared with domestic and foreign data, and it was found to be closest to JGHA data. The data of NAAS, BALLS and ASHRAE were judged to be too large. Therefore, in order to set up environmental design standards for domestic greenhouses, it is necessary to fully examine those data through further experiments.