Levels and Related Factors of Airborne Fungi in Microbial and Chemistry Laboratories in Universities  

Hwang, Sung-Ho (Department of Environmental Health, School of Public Health and Institute of Health and Environment, Seoul National University)
Jo, Hyun-Woo (Department of Environmental Health, School of Public Health and Institute of Health and Environment, Seoul National University)
Park, Dong-Uk (Department of Environmental Health, Korea National Open University)
Yoon, Chung-Sik (Department of Environmental Health, School of Public Health and Institute of Health and Environment, Seoul National University)
Ryu, Kyong-Nam (Department of Environmental Health, School of Public Health and Institute of Health and Environment, Seoul National University)
Ha, Kwon-Chul (Department of Biochemistry and Health Science, Changwon National University)
Publication Information
Journal of Korean Society of Occupational and Environmental Hygiene / v.20, no.1, 2010 , pp. 41-46 More about this Journal
Abstract
The purpose of this study is to assess the level of fungi concentration in the university laboratories in Seoul, Korea, and to investigate factors contributing to these concentrations. The samples were taken from three spots in each laboratory; the top of sink, the center of laboratory, and the front of ventilation system, i.e fume hood at the chemical laboratory and clean bench/biosafety cabinet at the microbial laboratory. Air samples were collected using the single-stage Anderson sampler (Quick Take 30) at a flow rate of 28.3 l/min for 5 min on nutrient media in Petri-dishes located on the impactor. Fifty-two air samples were collected from 19 different laboratories (13 microbiology laboratories, 6 chemistry laboratories) in the university, and concentrations of airborne fungi showed no significant difference (p>0.05) between microbiology and chemistry laboratory, and also no significant difference at three locations (sink, center, front of ventilation system) in microbiology and chemistry laboratories. Average concentrations of fungi in 19 laboratories ranged from 7 to 459 cfu/$m^3$, with an overall Geometric Mean of 52 cfu/$m^3$. Airborne fungi concentrations of 6 samples (12 %) exceeded 150 cfu/$m^3$, the guideline of WHO. The ratios of Indoor/Outdoor for airborne fungi ranged from 0.2 to 4.8 (mean = 1.6). Related factors were measured such as relative humidity, temperature, and laboratory area. Temperature and laboratory area showed no significant relations to concentrations of airborne fungi except for relative humidity in the laboratory Concentrations of fungi were significant different (p<0.01) between rainy or cloudy and sunny. However, there was no significant difference between general ventilation and nongeneral ventilation.
Keywords
Airborne fungi; University; laboratory; Weather; Relative humidit;
Citations & Related Records
Times Cited By KSCI : 6  (Citation Analysis)
연도 인용수 순위
1 Lavoie J, Dunkerley CJ, Kosaltsky T, Dufresne A. Exposure to aerosolized bacterial and fungi among collectors of commercial, mixed residential, recyclable and compostable waste. Sci Total Environ 2006;370(1);23-28   DOI   ScienceOn
2 Mui, K.W., Wong, L.T., Hill, P.S. Risks of unsatisfactory airbome bacteria level in air-conditioned offices of subtropical climates. Build Environ 2008;43: 475-479   DOI   ScienceOn
3 National Institute for Occupational Safety and Health(NOSH). NIOSH Manual of Analytical Methods. 4th edition, DHHS Publication, 1994; 94-113
4 Rusca, S., C. N., D. P., O. A. : Effects of bioaerosol exposure on work-related symptoms among Swiss sawmill workers. Int Arch Occup Environ Health 2007; 1:12-17
5 환경부. 다중이용시설등의 실내공기질관리법 시행규칙, 환경부령 2004;제156호
6 Desai, M. S., Ghosh, S. K. : Aflatoxin related hazards among rice mill Workers. J Toxic: Toxin Reviews 1989;8:81-88   DOI
7 한국과학기술인연합. 국내 이공계 실험실 안전 실태파악을 위한 설문조사 결과 보고서. 한국과학기술인연합 과학기술정책자료집 3, 2003
8 American Conference of Governmental Industrial Hygienists (ACGIH). Bioaerosols Assessment and Control. ACGIH, Cincinnati, Ohio, 1999
9 American Conference of Govemmental lndustrial Hygienists (ACGIH). Threshold limit values for chemical substances and physical agents and biological exposure indices. ACGIH. Cincinnati. Ohio, 2001
10 Guo, H., Lee, S.C., Chan, L.Y. Indoor air quality investigation at air-conditioned and non-air conditioned markets in Hong Kong. Int. J. Science. Total. Environ 2004;323:87-98   DOI
11 Huseuh, P. R., Teng, L. J. and Yang, P. C. Persistence of a Multidrug-Resistant Pseudomoas aeruginosa Clone in an Intensive Care Bum Unit. J Clin Microbiol 1998;36(5):1347-1351
12 김기연, 노영만, 김윤신, 이철민, 심인숙. 일반사무실 실내공기 내 부유미생물의 분포 양상. 한국산업위생학회지 2008; 18(1):11-19
13 교육과학기술부. http://www.mest.go.kr/
14 김기연, 이창래, 김치년,원종욱, 노재훈. 종합병원의 실내공기에 분포하는 부유세균과 진균의 입경별 종류와 특성. 한국산업위생학회지 2006;16(2):101-109
15 김기연, 정연일, 김치년, 원종욱, 노재훈. 사료제조공장 내 공기 중 세균과 진균 분포에 관한 연구. 한국산업위생학회지 2007;17(4):335-342
16 김윤신, 이은규, 엽무종, 김기영, 다중이용시설에서의 실내 공기중 미생물 분포에 관한 연구. 한국환경위생학회지 2002;28:85-92   과학기술학회마을
17 박재범, 김기연, 장규엽, 김치년,이경종. 다중이용시설 내부에 분포하는 부유진균의 입경별 농도 특성. 한국환경위생학회지 2002;28(1):85-92   과학기술학회마을
18 송주희, 민진영, 조경아, 윤영희, 백남원. 서울시 일부종합병원의 공기 중 미생물 농도 분포. 한국환경보건학회지 2007;33(2):104-114   과학기술학회마을
19 조경아. 유아교육시설 내 실내 공기 중 호흡성 미생물에 관한 연구. 서울대학교 석사 학위논문, 2005
20 조준호, 백남원. 서울시 일부 지하철 역사 내 공기 중 진균농도에 관한 연구. 한국환경보건학회지 2009;35(6):487-494
21 World Health Organization (WHO). : Indoor air quality-biological contanminants. Report on a WHO meeting, WHO Regional Publications European series No.31. WHO, Copenhagen, Denmark, 1988.
22 Simmons, R.B., Price D.L., Noble, J.A., Crow, S.A., Aheam, D. G. : Fungal colonization of air filters from hospital. Am Ind Hyg Assoc J 1997;58:900-904   DOI   ScienceOn
23 Tsai, M. Y., Liu, H. M. : Exposure to culturable airbome bioaerosols during noodle manufacturing in central Taiwan. Sci Total Environ. Doi, 2008;10:1016
24 U.S. EPA, Interim Indoor Radon and Radon Decay Product Measurement Protocols, 1986:520:1-86-04