• Title/Summary/Keyword: Indoor-Outdoor Temperature

Search Result 265, Processing Time 0.024 seconds

CO2 Sensing Properties of SnO2-Cr2O3 Composite Nanofibers Via Electrospinning Method (전기방사법으로 합성된 SnO2-Cr2O3 복합나노섬유의 이산화탄소 가스감응 특성)

  • Lee, Jae-Hyoung;Kim, Jae-Hun;Kim, Jin-Young;Kim, Sang Sub
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.4
    • /
    • pp.289-295
    • /
    • 2017
  • Detection of $CO_2$ gas in both indoor and outdoor atmospheres is now becoming an important issue because of greenhouse effect and climate crisis. In this study, gas sensors based on $SnO_2-Cr_2O_3$ composite nanofibers were fabricated by the electrospinning method to detect $CO_2$ gas. The gas sensors showed a response to ppm level of $CO_2$ gas from room temperature to $200^{\circ}C$ while the highest response was observed at $150^{\circ}C$. The gas response is enhanced by the catalytic property of $Cr_2O_3$. Selective $CO_2$ detection is obtained through the chemical reaction of $Cr_2O_3$ to chromium carbonate. All the results suggest the $SnO_2-Cr_2O_3$ composite material is promising for the use of $CO_2$ gas sensors.

Fabrication and Verification of a Water Quality Sensor Equipped with Active RFID Function for Real Time Location (위치추적용 능동형 RFID 기능을 장착한 수질 측정 센서의 제작 및 검증)

  • Jung, Young-Sub;Chang, Hun;Kim, Jin-Young;Kang, Joon-Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.17 no.1
    • /
    • pp.113-120
    • /
    • 2009
  • Through the automatic sensing of the environment, USN technology can give the best services. In this work, we have developed an active RFID system and examined its performance. By implementing it into water quality sensors, we constructed a system that can detect diverse indoor/outdoor environment and provide information about the pollution level obtained from the temperature and PH sensors. Our RF system had an internal Print-on-PCB antenna for the miniaturization of the tag. We used a RF transceiver CC2510 chipset of TI company to realize the active RFID function. By using RSSI constants obtained, we performed the evaluation of real time location accuracy with a software written in Labview. Among 10 arbitrary locations, we obtained average measurement errors of 1.69 m in x axis and 1.66 m in y axis. This technology can be applied to logistics, environmental monitoring, prevention of missing children and various applications.

  • PDF

Intelligent and Responsive Window Opening-Closing Operation Process for Carbon Dioxide(CO2) Management of Secondary School Classroom (중등학교 교실의 이산화탄소(CO2) 관리를 위한 지능형 창호개폐 작동 프로세스)

  • Choi, Yoon-Young;Lee, Hyun-Soo
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.25 no.4
    • /
    • pp.19-30
    • /
    • 2018
  • The school classroom is a common living place where students spend 7 to 14 hours a day to prepare for their careers. Therefore, if the ventilation of the classroom is not properly performed, it may lead to the deterioration of learning ability due to the unclear air. The concentration of carbon dioxide in the classroom is reported to be high, and the increase in carbon dioxide concentration has a negative effect on the learner's academic performance. In this context, the purpose of this study is to propose a methodology for intelligent and responsive window opening-closing operation process that can reduce the concentration of $CO_2$ in the classroom in order to build a support space that can create an effective teaching-learning environment for adolescents. The specific objectives are as follows. First of all, we define the concept of window opening-closing operation. Secondly, twe develop the operation process of window opening-closing. Thirdly, we develop an algorithm for real-time window opening and closing (process) (Window Opening-Closing Operation Process). Finally, we verify the intelligent responsive window opening-closing operation process through developing examples of window opening-closing operation process using the parametric design program. This study is a preliminary study to develop algorithms necessary for window opening-closing operation. Based on the first-order algorithm, We simulated window opening-closing operations according to a hypothetical scenario. As a result, This study can show that the window is open and close depending on the $CO_2$ concentration, but the $CO_2$ concentration in the room is higher than outdoors. Consequentially, we suggest that it is necessary to develop an algorithm to supplement these results because window is often not working when the temperature difference between indoor and outdoor in winter is large.

Penicillium Diversity from Intertidal Zone in Korea

  • Park, Myung Soo;Lee, Seobihn;Oh, Seung-Yoon;Lim, Young Woon
    • 한국균학회소식:학술대회논문집
    • /
    • 2016.05a
    • /
    • pp.11-11
    • /
    • 2016
  • Penicillium species are commonly isolated from various outdoor and indoor environments, including marine environments such as sponges, algae and sand. Penicillium is especially important because numerous bioactive compounds have been isolated. Penicillium was the most common species in intertidal zone in Korea, however the diversity and ecological roles of Penicillium in intertidal zone are not clarified. We explored diversity and ecological roles of marine-derived Penicillium from tidal flat and sea sand in Korea. The diversity of marine-derived Penicillium from Korea was investigated using both culture-dependent and culture-independent approach by ${\beta}$-tubulin sequence. In addition, we evaluated optimal temperature, halo-tolerance, and enzyme activity of Penicillium strains, such as extracellular alginase, endoglucanase, ${\beta}$-glucosidase, and protease. For culture-dependent approach, a total of 182 strains of 62 Penicillium species were isolated, with 53 species being identified. The most common species was Penicillium oxalicum, followed by P. crustosum, P. brasilianum, P. koreense, and P. griseofulvum. Species richness and composition were not significantly different by season, substrates, and seaside. For culture-independent approach using Illumina sequencing, 73 OTUSs were detected. The most frequently observed species was P. antarcticum, followed by P. koreense, P. crustosum, and P. brevicompactum. Diversity of Penicillium was higher during winter season than during summer season and in western sea than in southern sea, respectively. Community structure was significantly different by season and sea side. 52 species were detected by both methods. Unique species were isolated from each of methods - 10 from culture methods and 21 from Illumina sequencing. Furthermore, salinity adaption of the Penicillium varied depending on species. Many Penicillium species showed endoglucanase, ${\beta}$-glucosidase, and protease activity. Some species including P. paneum and P. javanicum degraded the polycyclic aromatic hydrocarbons. Thus, our results demonstrate that intertidal zone in Korea harbors diverse Penicillium community and marine-derived Penicillium play important ecological roles as decomposers of organic material in marine environments.

  • PDF

An Experimental Study on Radiation/Convection Hybrid Air-Conditioner (복사-대류 겸용 하이브리드 냉방기에 대한 실험 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.288-296
    • /
    • 2019
  • Radiation cooling has used ceilings or floors as cooling surfaces. In such cases, to avoid moisture condensation on the surface, the surface temperature needs be higher than the dew point temperature or an additional dehumidifier is added. In this study, with a goal for residential application, intentional moisture condensation on the cooling surface was attempted, which increased the cooling capacity and improved the indoor comfortness. This method included two separate refrigeration cycles - convection-type dehumidifying cycle and the panel cooling cycle. Test results on the panel cooling cycle showed that, at the standard outdoor ($35^{\circ}C/24^{\circ}C$) and indoor ($27^{\circ}C/19.5^{\circ}C$) condition, the refrigerant flow rate was 8.8 kg/h, condensation temperature was $51^{\circ}C$, evaporation temperature was $8.8^{\circ}C$, cooling capacity was 376 W and COP was 1.75. Furthermore, the panel temperature was uniform within $1^{\circ}C$ (between $13^{\circ}C$ and $14^{\circ}C$). As the relative humidity decreased, the cooling capacity decreased. However, the power consumption remained approximately constant. In the convection-type dehumidification cycle, the refrigerant flow rate was 21.1 kg/h, condensation temperature was $61^{\circ}C$, evaporation temperature was $5.0^{\circ}C$, cooling capacity was 949 W and COP was 2.11 at the standard air condition. When both the radiation panel cooling and the dehumidification cycle operated simultaneously, the cooling capacity of the radiation panel cycle was 333 W and that of the dehumidification cycle was 894 W, and the COP was 1.89. As the fan flow rate decreased, both the cooling capacity of the radiation panel and the dehumidification cycle decreased, with that of the dehumidification cycle decreasing at a higher rate. Finally, a possible control logic depending on the change of the cooling load was proposed based on the results of the present study.

Analysis of Microclimate and Conservation Environment of the Stone Buddha and Shrine in Unjusa Temple, Hwasun, Korea (화순 운주사 석조불감의 보존환경 및 미기상 분석)

  • Park, Sung-Mi;Lee, Chan-Hee;Lee, Myeong-Seong;Kim, Sa-Dug
    • Economic and Environmental Geology
    • /
    • v.42 no.1
    • /
    • pp.73-84
    • /
    • 2009
  • The stone Buddha and Shrine of Unjusa temple (Korean Treasure No. 797) at Hwasun formed in Koryo Dynasty is unique style which faces each other the back parts of south and north within the stone Shrine. The stone Buddha and Shrine is highly evaluated in historical, artistic and academic respects. But, the stone properties have been exposed in the open system various aspects of degradations weathered for a long time without specific protective facilities. To inquire into relative deterioration and environmental factor, air temperature and relative humidity of the stone Buddha and Shrine were monitored for a year of the indoor and outdoor, respectively. As a result, the temperature shows increase and decrease according to the seasons in the tendency to clear. While the relative humidity is high to keep all four seasons. Highly relative humidity environment induces dew condensation on the interior of stone Buddha and Shrine. The dew condensation is recorded at the spring, summer and winter season. The summer season is double the total of spring and winter season. In the case of summer, dew condensation is long time continued due to high temperature and relative humidity that is kept by more than nearly 100%. There is progress towards chemical weathering throughout dissolve rock properties and alteration on the rock surface. In the case of winter, dew condensation is not kept for a long time as summer. In the winter, which showing a below zero may add physical weathering throughout moisture that happen by dew condensation to repeat freezing and thawing. Therefore, the reduction plan of the relative humidity effect on dew condensation should be prepared.

Predicting Influence of Changes in Indoor Air Temperature and Humidity of Wooden Cultural Heritages by Door Opening on Their Conservation Environment (개방에 따른 실내 온습도 변화가 목조문화재 보존환경에 미치는 영향 예측)

  • Kim, Min-Ji;Shin, Hyun-Kyeong;Choi, Yong-Seok;Kim, Gwang-Chul;Kim, Gyu-Hyeok
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.798-803
    • /
    • 2015
  • This study was conducted to predict the effect of door opening in wooden cultural heritages (WCHs) on their conservation environment. For this prediction, measured relative humidity (RH) and surface wood moisture content (MC) of inner part of wood columns in open wooden building and neighboring closed wooden building were compared with minimum RH, including the duration of minimum RH, and MC required for spore germination and resultant growth of wood-degrading fungi reported in some literatures. Moisture conditions, namely RH of inside wooden building and MC of wood was unsuitable for decay and sap-stain fungi all the year round; however, moisture conditions during summer season was suitable for spore germination and resultant growth of surface mold fungi, regardless of door opening. When compared, the duration of minimum (75%) or higher RH and the number of wood columns with MC level greater than the minimum MC (15%) during summer season, the surface mold related to the conservation environment of inside wooden building was somewhat better in open building than in closed building. Rather, doors should be opened in closed building for reducing indoor RH as a necessary measure during summer season when outdoor RH is high.

Deterioration and Microclimate in the Shelter for the Gaetaesajiseokbulibsang (Standing Triad Buddha Statues in Gaetaesaji Temple Site), Nonsan, Korea (논산 개태사지석불입상의 손상도와 보호각 내부의 미기후 환경)

  • Kim, Ji-Young;Park, Sun-Mi;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.25 no.2
    • /
    • pp.179-196
    • /
    • 2009
  • The Gaetaesajiseokbulibsang (Treasure No. 219) consists of light gray and coarse to medium-grained granodiorite with feldspar phenocrysts in part. Magnetic susceptibility of the rock material was measured as 12.06(${\times}10^{-3}$ SI unit), being different from the granite($0.19{\times}10^{-3}$ SI unit) in the Mt. Cheonho. This indicates the raw material has been supplied from the outside. As a result of deterioration assessment, exfoliation of the Right Buddha, cement and dust of the Main Buddha were estimated as 35.2%, 21.1% and 25.0%. The ultrasonic velocity was measured as 2850.2m/s(Main Buddha), 2648.4m/s(Left Buddha) and 2644.5m/s(Right Buddha). The compressive strength calculated from the velocity showed low in the Right Buddha among three and the all pedestal parts which corresponds to the result of deterioration assessment. The indoor mean temperature and relative humidity of the shelter were $13.7^{\circ}C$ and 79.0%. It is evaluated that the indoor microclimate was stable and the shelter functioned to reduce climatic fluctuation of the outdoor. However, water condensation was occurred on the surface of the pedestal part during spring and summer, and freezing in winter season might also be done. These factors were probable to be a main cause of the surface exfoliation of the Triad Buddha Statues. Therefore, dehumidification and heating system in the shelter should be applied to prevent further deterioration.

  • PDF

Experimental Study on behavior of the Lightweight Air-foamed Soil Considering Freezing-thawing and Soaking Conditions (동결융해 및 수침조건을 고려한 경량기포혼합토의 거동 실험 연구)

  • Kang, Daekyu;Shin, Eunchul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.5
    • /
    • pp.37-46
    • /
    • 2016
  • In order to determine the variability of environmental characteristics of lightweight air-foamed soil using marine clay according to freezing-thawing and soaking conditions, unconfined compressive strength of the lightweight air-foamed soil samples made by changing the amount of cement under curing conditions of outdoor low temperature, underground or indoor wetting were observed. Compressive strength was not increased under freezing-thawing (temperature range of $-9.1^{\circ}C{\sim}17.2^{\circ}C$) regardless of the amount of cement but the more cement using, it was increased rapidly by underground curing conditions within 30 cm beneath ground level. Therefore, it is necessary to install insulation layer cutting off exterior cold air after construction of lightweight air-foamed soil in condition of freezing-thawing. Bulk density was increased too small under the long-time soaking condition, it tended to decrease rapidly when samples were dried up and had below 6% of water contents. But variability of compressive strength and bulk density was very small for preventing drying and keeping its wet state. The lightweight air-foamed soil that installed beneath ground water level or covered by soil can be evaluated as a long-term reliable construction material.

Levels and Related Factors of Airborne Fungi in Microbial and Chemistry Laboratories in Universities (일부 대학교 미생물실험실 및 화학실험실에서의 진균 분포 및 관련인자)

  • Hwang, Sung-Ho;Jo, Hyun-Woo;Park, Dong-Uk;Yoon, Chung-Sik;Ryu, Kyong-Nam;Ha, Kwon-Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • The purpose of this study is to assess the level of fungi concentration in the university laboratories in Seoul, Korea, and to investigate factors contributing to these concentrations. The samples were taken from three spots in each laboratory; the top of sink, the center of laboratory, and the front of ventilation system, i.e fume hood at the chemical laboratory and clean bench/biosafety cabinet at the microbial laboratory. Air samples were collected using the single-stage Anderson sampler (Quick Take 30) at a flow rate of 28.3 l/min for 5 min on nutrient media in Petri-dishes located on the impactor. Fifty-two air samples were collected from 19 different laboratories (13 microbiology laboratories, 6 chemistry laboratories) in the university, and concentrations of airborne fungi showed no significant difference (p>0.05) between microbiology and chemistry laboratory, and also no significant difference at three locations (sink, center, front of ventilation system) in microbiology and chemistry laboratories. Average concentrations of fungi in 19 laboratories ranged from 7 to 459 cfu/$m^3$, with an overall Geometric Mean of 52 cfu/$m^3$. Airborne fungi concentrations of 6 samples (12 %) exceeded 150 cfu/$m^3$, the guideline of WHO. The ratios of Indoor/Outdoor for airborne fungi ranged from 0.2 to 4.8 (mean = 1.6). Related factors were measured such as relative humidity, temperature, and laboratory area. Temperature and laboratory area showed no significant relations to concentrations of airborne fungi except for relative humidity in the laboratory Concentrations of fungi were significant different (p<0.01) between rainy or cloudy and sunny. However, there was no significant difference between general ventilation and nongeneral ventilation.