• Title/Summary/Keyword: Indoor environment

Search Result 2,576, Processing Time 0.033 seconds

Design and Implementation of Big Data Cluster for Indoor Environment Monitering (실내 환경 모니터링을 위한 빅데이터 클러스터 설계 및 구현)

  • Jeon, Byoungchan;Go, Mingu
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.13 no.2
    • /
    • pp.77-85
    • /
    • 2017
  • Due to the expansion of accommodation space caused by increase of population along with lifestyle changes, most of people spend their time indoor except for the travel time. Because of this, environmental change of indoor is very important, and it affects people's health and economy in resources. But, most of people don't acknowledge the importance of indoor environment. Thus, monitoring system for sustaining and managing indoor environment systematically is needed, and big data clusters should be used in order to save and manage numerous sensor data collected from many spaces. In this paper, we design a big data cluster for the indoor environment monitoring in order to store the sensor data and monitor unit of the huge building Implementation design big data cluster-based system for the analysis, and a distributed file system and building a Hadoop, HBase for big data processing. Also, various sensor data is saved for collection, and effective indoor environment management and health enhancement through monitoring is expected.

Evaluation of Indoor Thermal Environment of Houses using for heating in winter (도시가스 사용 주택의 동절기 실내온열환경 평가)

  • Park, Seok-Bong;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.125-131
    • /
    • 2005
  • This study identified satisfaction with gas heating and indoor thermal environment, targeting houses using gases for heating. 1) Thermal environment is relatively satisfactory except that indoor humidity is low. 2) A question that indoor temperature has to be decreased for saving energy was given and about two thirds of the respondents answered that temperature has to be lowered. When they were asked how to save energy 57% answered that they put on more clothes and 27% answered that they lower indoor temperature If consistent promotion on energy saving is implementer it's believed that energy can be effectively saved. 3) People wear simple clothes when they stay indoor because they think it is comfortable. However, for energy saving. they gave to wear warm clothes though they stay indoor.

Development of Guidelines for Indoor Environment in Apartment Remodeling Projects (아파트 리모델링의 실내환경 계획지침 개발)

  • Choi, Yoon-Jung
    • Journal of the Korean housing association
    • /
    • v.20 no.3
    • /
    • pp.1-10
    • /
    • 2009
  • The final aim of this study was to propose guidelines for the indoor environment of apartment remodeling projects. The first task of this study was to understand the major elements and the actual condition of the remodeling for apartment unit by carrying out in-depth interviews on residents and specialists. The open-access interviews were conducted with interior designers who have a wide experience of apartment remodeling and residents who live in recently remodeled apartment units. The second task was to evaluate the actual condition of the indoor environment and to analyze the main factors that affect the indoor environment in remodeled apartment units. Field measurements were carried out in twenty apartment units occupied after remodeling, recording indoor environment elements (indoor temperature, globe temperature, relative humidity, $CO_2$, CO, PM10, TVOC, HCHO, illumination, and equivalent noise level). Moreover, resident interviews and researcher observations were carried out to determine the contents of the remodeled unit and to investigate the architectural and living factors(like ventilation characteristics, etc.) related to the indoor environment. The results are as follows. The remodeling elements generally included the changing of lighting fixtures and finishing materials in all the spaces, the integration of the balcony into the children's room, the installation of furniture in the kitchen and the entrance, the changing storage furnitures and equipments in the bathroom. The average levels of each unit of relative humidity, $CO_2$, TVOC, HCHO, equivalent noise level, and illumination were proved to be on the whole in inadequate condition. The factors that affect these indoor elements were classified as remodeling factors (remodeling amounts, extent balcony integration, and lighting fixture exchange), ventilation characteristics, and living factors. According to these results, this research proposed the guidelines for the indoor environment in apartment remodeling projects.

A Study on the Assessment of the IAQ during Nightime (공동주택에서 취침 시 실내공기환경 평가에 관한 연구)

  • Kim, Dong-Gyu;Kim, Sam-Uell;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.93-98
    • /
    • 2007
  • Effort has been performed for latest 20 years to improve resident's comfort and indoor environment in building. And interest and effort to improve indoor air environment among various indoor environment elements have continuously increased since 1990s, because it is examined scientifically that various contaminants generated indoor affect human body. Specially, indoor air contaminants generated from apartments are those exhausted from resident's indoor environment, closing materials and household. Indoor air environment in buildings is different according to pollution degree, existence availability of pollution source, ventilation amount, and meteorology. It is known that other contaminants more than about 900 kinds generate according to a kind of work or action in a room. Specially, nowadays buildings are well insulated and confidentiality-centered for environment protection and economical side. So indoor air contaminants are generated from indoor air pollution sauces of unprepared ventilation, human body carbon dioxide emissions, and various building materials. when these are accumulated in long term human body, it is harmful to resident's health, but awareness for this is very insufficient. Because bedroom is space that people inhabit for a long time by unconscious state and indoor environment occupies important part for resident's health and quality of life at sleep, the actual condition of air quality is investigated, improvement countermeasure is considered, and ventilation amount is analyzed. In this study, putting case that the most longest stayed time is sleeping time when people inhabit in the apartment, the air quality according to volume of bedroom space at sleep was measured and analyzed, and the data acquired will be the basis for improvement on this.

Pattern Classification of PM -10 in the Indoor Environment Using Disjoint Principal Component Analysis (분산주성분 분석을 이용한 실내환경 중 PM-10 오염의 패턴분류)

  • 남보현;황인조;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.1
    • /
    • pp.25-37
    • /
    • 2002
  • The purpose of the study was to survey the distribution patterns of inorganic elements of PM-10 in the various indoor environments and analyze the pollution patterns of aerosol in various places of indoor environment using a pattern recognition method based on cluster analysis and disjoint principal component analysis. A total of 40 samples in the indoor had been collected using mini-vol portable samplers. These samples were analyzed for their 19 bulk inorganic compounds such as B, Na, Mg, Al, K, Ca, Ti, V, Cr, Fe, Ni, Cu, Zn, As, Se, Cd, Ba, Ce, and Pb by using an ICP-MS. By applying a disjoint principal component analysis, four patterns of the indoor air pollutions were distinguished. The first pattern was identified as a group with high concentrations of PM-10, Na, Mg, and Ca. The second pattern was identified as a group with high concentrations B, Mg, At, Ca, Fe, Cu, and Ba. The third pattern was a group of sites with high concentrations of K, Zn. Cd. The fourth pattern was a group with low concentrations PM-10 and all inorganic elements. This methodology was found to be helpful enough to set the criteria standard of indoor air quality, corresponding pollutants, and classification of indoor environment categories when making an indoor air quality law.

Characterization of Indoor Temperature and Humidity in Low-income Residences over a Year in Seoul, Korea

  • Lee, Daeyeop;Lee, Kiyoung;Bae, Hyunjoo
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.3
    • /
    • pp.184-193
    • /
    • 2017
  • People spend the majority of their time in indoor environments. Maintaining adequate indoor temperature and humidity is necessary to support health and improve quality of life. However, people with low incomes can be vulnerable because they may not be able to use effective cooling and heating systems in their homes. In this study, the indoor temperature and humidity in low-income residences over a year in Seoul, Korea was characterized. Indoor temperature and humidity were measured in three types of homes (12 rooftop residences, 16 basement residences, and 18 public rental apartments) occupied by low-income residents. Both differed significantly among the three types of residence, particularly during the summer and winter seasons. A regression model between indoor and outdoor temperature detected a heating threshold at $3.9^{\circ}C$ for rooftop residences, $9.9^{\circ}C$ for basement residences, and $17.1^{\circ}C$ for public rental apartments. During tropical nights and cold-wave advisory days, rooftop residences showed the most extreme indoor temperatures. This study demonstrates that people living in rooftop residences could be at risk from extreme hot and cold conditions.

Energy Saving Effect and Improvement of Indoor Thermal Environment through the Window Retrofit (창호 리트로피트를 통한 에너지 절감 및 실내 열환경 개선 효과 분석에 관한 연구)

  • Jeong, Jin-Woo;Ju, Jung-Hoon;Cho, Dong-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.3
    • /
    • pp.29-36
    • /
    • 2018
  • The goal of this study is to retrofit the windows of residential buildings and to activate the green remodeling by verifying energy saving and indoor thermal environment. As a result of analysis of the energy saving effect of 458 units window retrofits, it was possible to reduce the energy requirement by 48.20% ~ 54.97%. According to the improvement on indoor environment, it was possible to operate by reducing heating temperature and supply time. The actual gas consumption of the heating period was reduced by 25% compared with that of the window retarder to save 28,968 thousand won of heating energy cost. Resident's satisfaction surveys were conducted one year after window retrofit. More than 80% of the respondents answered that they satisfied the improvement on window performance, indoor thermal environment and indoor sound environment. As a result, we verified the energy saving effect and the improvement on the indoor environment through window retrofits.

A Review of Some Representative Techniques for Controlling the Indoor Volatile Organic Compounds

  • Kabir, Ehsanul;Kim, Ki-Hyun
    • Asian Journal of Atmospheric Environment
    • /
    • v.6 no.3
    • /
    • pp.137-146
    • /
    • 2012
  • Poor indoor air quality is now worldwide concern due to its adverse impacts on our health and environment. Moreover, these impacts carry a significant burden to the economy. Various technical approaches (e.g., biological, activated carbon fiber (ACF), photocatlytic oxidation (PCO), etc.) have gained popularity in controlling indoor volatile organic compounds (VOCs). This is because removing indoor VOC sources or increasing ventilation rates is often not feasible or economical. This review provides an overview of the various air purification technologies used widely to improve indoor air quality. Although most of these technologies are very useful to remove indoor VOCs, there is no single fully satisfactory method due to their diversity and presence at the low concentration. To achieve technical innovations and the development of specific testing protocols, one should possess a better knowledge on the mechanisms of substrate uptake at VOC concentrations.

A Comparative Study on Clinical Gait Abilities of Stroke Patients According to Indoor and Outdoor Environments

  • Hwang, Hyesun;Woo, Youngkeun;Chung, Yijung
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.3
    • /
    • pp.356-366
    • /
    • 2021
  • Objective: This study aimed to compare gait ability through gait evaluations in indoor and outdoor environments according to the general characteristics and walking ability of stroke patients. Design: Crossed-sectional study. Methods: The subjects of this study were 57 hospitalized stroke patients.The study subjects were asked to select an indoor environment and an outdoor environment in random order, and the Timed Up and Go Test (TUG), 10-Meter Walk Test (10MWT), Figure-Eight Walk Test (F8WT) and the Functional Gait Assessment (FGA) were used to assess each environment. Results: The TUG, 10MWT, F8WT time and number of steps, and FGA showed a significant decrease in gait ability in the outdoor environment compared to the indoor environment (p<0.05). Although the TUG, 10MWT, and the time required for the F8WT were statistically higher in the outdoor compared to the indoor environment at points 2, 3, and 4, but not 5 of the functional ambulatory category (FAC), significant increases in the number of steps of the F8WT were found in the outdoor compared to the indoor environment for only points 2 and 3 of the FAC (p<0.05). In the FAC 3 and 4, there was a statistically significant decrease in the outdoor compared to the indoor environment only in the FGA (p<0.05). Conclusions: Therefore, it has been shown that the gait ability of stroke patients is reduced in the outdoor environment compared to the gait ability in the indoor environment.

Management Policy and Control Technology for Indoor Air Quality in Korea (국내 실내공기질 관리정책의 변천 및 제어기술의 현황)

  • Bae, Gwi-Nam;Ji, Jun-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.4
    • /
    • pp.378-389
    • /
    • 2013
  • In Korea, studies on the indoor air quality have been conducted since mid of 1980s. The turning point occurred in 2003 by establishing the act of the indoor air quality management for public facilities. According to the law, the basic plan for indoor air quality management is prepared by government every five years, affecting greatly governmental policy and related academia and industries. Indoor air quality survey was mostly carried out among indoor air quality researches. After then, assessment of health effect and air cleaning technology were studied. Although various control technologies for particle, bioaerosol, odor, and hazardous chemicals have been applied to indoor environments, breakthrough technologies are needed to solve real problems facing at the applied environments. In the future, issue of indoor air quality is more interested and both management policy and control technology are key factors in order to realize comfort and healthy indoor environments.