• 제목/요약/키워드: Indoor Air Temperature

검색결과 667건 처리시간 0.03초

Correlation of Air Pollutants and Thermal Environment Factors in a Confined Pig House in Winter

  • Choi, Hong L.;Kim, Ki Y.;Kim, Hyunook
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제18권4호
    • /
    • pp.574-579
    • /
    • 2005
  • Optimal management of indoor air quality in a confined pig house, especially in winter, is indispensable for preventing infectious respiratory disease to workers and animals. This study was performed to elucidate the correlation of aerial contaminants and climate factors in a confinement. It was observed that indoor air contaminants ion in the confinement was the highest at 2:00-5:00 pm in a day, followed by 8:00-11:00 pm and 8:00-11:00 am. This was attributed to the increase of pig activities in the afternoon. The concentration of total dust and total airborne bacteria was found to have a significant correlation with temperature and relative humidity (p<0.05). Correlation of total dust and total airborne bacteria, total dust and ammonia, and total dust and odor were shown statistically significant at 95% confidence level. In conclusion, temperature and total dust concentration correlated significantly with all the parameters except for hydrogen sulfide ($H_2S$). This could be explained by the fact the dryness of pig feces by increase of interior temperature and resuspension of feed deposited on the floor by the pig activity, resulted in high generation of dust which adsorbed and carried the airborne bacteria and odor compounds in a confined pig house. It was proved that the adsorptive capacity of dust with ammonia ($NH_3$) was higher than that with hydrogen sulfide ($H_2S$).

BLE 기반 RSSI와 SoC 내부 또는 국부 온도의 상관관계 (Correlation Analysis between BLE-based RSSI and SoC Internal or Local Temperature)

  • 김성창;이민정;오성빈;심준수;김진호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 춘계학술대회
    • /
    • pp.89-91
    • /
    • 2022
  • 실내에서 측위를 위해 주로 사용되는 무선 센서 네트워크(WSN)는 수신 신호 강도(RSSI)의 정확성에 의존한다. 이 RSSI는 간섭을 유발하는 여러 요인에 민감하며, 그 중 온도가 실내/외 환경에서 RSSI에 큰 영향을 미친다는 국외 연구 사례가 있다. 실내에서는 열원이나 공조 시스템으로 인해 실내 공간의 온도가 고르지 않으며, 특정 위치에서는 잦은 온도 변화가 발생한다. 특히, 실내 화재 상황 시 대피 경로 안내를 위해 정확한 측위 시스템이 요구되지만 Receiver 주변에서의 화재로 인해 국부적으로 높은 온도가 형성되어 RSSI 값에 영향을 미칠 수 있다. 본 논문에서는 SoC 내부 및 국부 온도와 RSSI의 상관관계 분석을 통해 RSSI에 미치는 영향을 연구하고자 한다.

  • PDF

老人福祉施設의 冬.夏節期 室內 溫熱環境 測定 및 溫熱感 評價 (An Study on the Evaluation of Thermal Indoor Environment and Thermal Sensations during Winter and Summer in Elderly Welfare Facilities)

  • 곽호;류우동;황광일;홍원화
    • 한국주거학회논문집
    • /
    • 제14권1호
    • /
    • pp.19-27
    • /
    • 2003
  • This study aims to survey the living spaces of the welfare facilities for the aged to get the objective relationships between the physical thermal environment and the users' subjective responses. The surveys were made twice in winter and once in summer during 2001 and 2002. An ambient temperature, relative humidity, air velocity, globe temperature were measured as physical elements of thermal environment and the ASHRAE Psychophysical Voting Scale were used as an evaluation index for subjective responses. As the results, the aged respond thermally comfortable, in spite of the differences among important factors such as thermal sensations, humidity sensations and air velocity sensations. Also the physical thermal environmental elements and the subjective responses indices exceed thermal comfort range calculated by PMV(Predicted Mean Vote) and PPD(Predicted Percentage Dissatisfied). It shows that the insulation of walls of the facilities is not enough for heating and cooling seasons, and the indoor environmental control is necessary.

열원 및 공조설비의 최적제어시스템 현장 적용성에 관한 연구 (A Study on the Application of the Optimal Control System for Heat Source and HVAC System)

  • 백승재;김진;안병천;송재엽
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1014-1019
    • /
    • 2009
  • The optimal control system for heat source and HVAC system has been developed for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as time varying indoor load and outdoor temperatures. The optimal set-points of control parameters are supply air temperature and chilled or hot water temperatures. The optimal control study has been implemented for biosafety laboratory by using TRNSYS simulation program in order to investigate energy performance for heat source and HVAC system.

  • PDF

경남지역 지하생활공간 중 미량 유해물질인 포름알데히드의 농도 분포 특성 (Characteristics of Formaldehyde Concentrations in the Underground Spaces in Gyungnam Province)

  • 하권철
    • 한국환경보건학회지
    • /
    • 제30권5호
    • /
    • pp.353-357
    • /
    • 2004
  • The purpose of this research is to characterize formaldehyde as trace toxic air pollutant in the underground spaces in Gyungnam province. Air samples of formaldehyde were taken in the three underground spaces for ten months from April 2003 to January 2004. The IAQ(Indoor Air Quality) of underground spaces were controled using central ventilation(supply/exhaust) system. The levels of GM of airborne formaldehyde concentrations in three sampling spaces were well below applicable standards, Korean Ministry of Environment, 0.1 ppm. However, some sample of airborne formaldehyde concentrations in underground spaces 'B' and 'C' were in excess of standard, due to the commercial products in shop, structural material, and the climate having high humidity and temperature. There are statistical differences in levels of formaldehyde by sampling spaces (p=0.086).

Research and Development of RFIC Technology in Smart Temperature Information Material

  • Chang, Chih-Yuan;Hung, San-Shan;Chang, Yu-Chueh;Peng, Yu-Fang
    • Journal of Construction Engineering and Project Management
    • /
    • 제1권1호
    • /
    • pp.18-23
    • /
    • 2011
  • Conservation of energy and fuel is the trend in smart building design. Radio Frequency Integrated Circuit (RFIC) technology is often used in temperature sensing and signal transmission to manage indoor temperature, but it is rarely applied to the shell of the building. Heat retention and poor insulation in building shells are the largest causes of high energy consumption by indoor air conditioning. Through combining RFIC technology with temperature sensors, this study will develop smart temperature information material that can be embedded in concrete. In addition to accurately evaluating the effectiveness of shell insulation material, the already-designed Building Physiology Information System can monitor long-term temperature changes, leading to smarter building health management.

RESEARCH AND DEVELOPMENT OF RFIC TECHNOLOGY IN SMART TEMPERATURE INFORMATION MATERIAL

  • Chih-Yuan Chang;San-Shan Hung;Yu-Chueh Chang;Yu-Fang Peng
    • 국제학술발표논문집
    • /
    • The 4th International Conference on Construction Engineering and Project Management Organized by the University of New South Wales
    • /
    • pp.480-486
    • /
    • 2011
  • Conservation of energy and fuel is the trend in smart building design. Radio Frequency Integrated Circuit (RFIC) technology is often used in temperature sensing and signal transmission to manage indoor temperature, but it is rarely applied to the shell of the building. Heat retention and poor insulation in building shells are the largest causes of high energy consumption by indoor air conditioning. Through combining RFIC technology with temperature sensors, this study will develop smart temperature information material that can be embedded in concrete. In addition to accurately evaluating the effectiveness of shell insulation material, the already-designed Building Physiology Information System can monitor long-term temperature changes, leading to smarter building health management.

  • PDF

공동주택에 대한 Shaft Box형 이중외피의 적용에 관한 연구 (A Study on Application of Shaft-box Type Double Skin to Apartment Building)

  • 노지웅
    • KIEAE Journal
    • /
    • 제13권1호
    • /
    • pp.75-81
    • /
    • 2013
  • The balcony of our apartment building consists of unique construction similar to double skin. It is announced broadly that double skin is very effective system in improvement of natural ventilation and indoor thermal environment, and outdoor sound protection. So, for the improvement of indoor climate and energy saving, many peoples studied about environmental performance of our balcony construction. This study focus on shaft box facade, special form of box window construction. It consists of a system of box window with continuous vertical shafts that extend over a number of stories to create a stack effect. Proto-type was decided by analyzing various types of exiting apartments. Shaft box type balcony was created by setting up shaft space at a part of balcony. Air flow and contribution of air temperature were simulated, performance of shaft box type balcony was compared with existing balcony. Finally, we confirmed that shaft box type balcony has many possibility for improvement of indoor environment.

바닥면복사난방에서 Draft에 의한 쾌적열환경에 관한 연구 (A study on the comfort thermal environment by the Draft in floor panel heating system)

  • 이경희
    • 한국주거학회논문집
    • /
    • 제7권2호
    • /
    • pp.121-129
    • /
    • 1996
  • This study was to estimate how about various effects on the body thermal sensation as air velocity. clo. mean radiant temperature and resultant temperature are varied. The indoor thermal environment elements are measured under the five different of air velocity. Using the above considerations. the following results are obtained. ▶ The states, the air velocity under 0.5 m/s and 0.63 to 0.9 clo. were shown that the comfort zone of mean radiant temperature by 21.2~24.7C, the neutral point by 22.8C, the resultant temperature by 20.7-24.4C and the neutral point by 22.6C. ▶ On equal condition, the draft was occurred at a given air-velocity under 0.5m.s. It was also appeared the floor panel heating system affecting the body thermal sensation by the subject’s below-chest parts and the local discomfort by sensations on the feet and the knees.

  • PDF

침실 공기질 개선을 위한 강제 환기횟수에 관한 연구 (A study on Forced Ventilation Rate for Bedroom Indoor Air Quality Improvement)

  • 김동규;이성;김세환
    • KIEAE Journal
    • /
    • 제9권1호
    • /
    • pp.85-90
    • /
    • 2009
  • The indoor air quality is one of the most important issues of designing ventilation in high rise apartment buildings. This study suggested proper ventilation rate in the apartment bedroom where mechanical ventilation system has installed. Six university students(four male and two female) were participating in the experiment. Experiments were performed in environmental chamber. Experimental conditions were combinations from three ventilation rate 0, 0.4 and 0.7. Measurement items during 8 hours of experimental time were temperature, humidity, carbon dioxide concentrations and questionnaire surveyed aftrer sleeping. The concentration of Carbon Dioxide depending on ventilation rate in the chamber was analyzed for proper ventilation rate. The results of this paper can be summarized as follows. (1) When two persons experiment, 0.7 ventilation rate was in excess of 1000ppm. (2) When one person experiment, 0.7 and 0.4 ventilation rates were satisfied the criteria of IAQ. (3) It compared 0.4 with 0.7 in the ventilation rate, 0.4 ventilation rate could reduced about 80% of the power by fan similarity law.