• Title/Summary/Keyword: Index Profile

Search Result 633, Processing Time 0.026 seconds

Maintaining Optimal Voltage Profile by the Operation of UPFC (UPFC 운용에 의한 전력 시스템 최적 전압 유지)

  • Kim, Tae-Hyun;Moon, Chae-Joo;Park, Jong-Keun;Moon, Seung-Il;Seo, Jang-Cheol;Han, Byung-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.265-267
    • /
    • 2000
  • A method to compute the reactive powers of the added buses by the decoupled UPFC model for the optimal voltage profile is presented, by which the voltage magnitudes of PQ buses can get closer to the reference value(usually one p.u.). The performance index for assessing how much the voltage magnitude is closer to the reference value is defined as the squared sum of the present voltage minus the reference voltage multiplied by the weighting number associated with the relative importance of the buses. Numerical example in a 10-unit 39-bus power system with 2 UPFC's shows that the performance index can be very much reduced by operating multi UPFC's with the reactive powers for the optimal voltage profile proposed in this paper.

  • PDF

Dispersive White-light Interferometry for in-situ Volumetric Thickness Profile of Thin-film Layers and a refractive index (분산형 백색광 간섭계를 이용한 미세 박막 구조물의 삼차원 두께 형상 및 굴절률의 실시간 측정)

  • Ghim Y.S.;Kim S.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.23-24
    • /
    • 2006
  • We present a dispersive scheme of white-light interferometry that enables not only to perform tomographical measurements of thin-film layers but also to measure a refractive index without mechanical depth scanning. The interferometry is found useful particularly for in-situ 3-D inspection of micro-engineered surfaces such as liquid crystal displays, semi-conductor and MEMS structure, which requires for high-speed implementation of 3-D surface metrology.

  • PDF

A Study of Functional Evaluation in Stroke Patients (뇌졸중 환자의 기능평가에 대한 연구 -Modified Barthel Index 및 PULSES Profile에 의한 평가성적을 중심으로-)

  • Ahn Jung-Kuk;Lim Hye-Hyun;Ahn So-Yoon
    • The Journal of Korean Physical Therapy
    • /
    • v.4 no.1
    • /
    • pp.43-57
    • /
    • 1992
  • This study was conducted from August, 1980 to March, 9991 to the 40 subjects who were admitted to Kosin Medical Center and received rehabilitation treatment and discharged under the impression of stroke. The objectives are to evaluate the function of the activites of daily living and comprehensive function and find the status of rehabilitation treatment by Modified Barthel Index and PULSES Profile when first requested or rehabilitation treatment(T1), at 2 weeks after rehabilitation treatment(T2), at discharge(T3) and at the time of ambulatory treatment after 2 weeks(T4). The study materials were clinical charts and functional evaluation sheets, and the results are as follows : 21 subject$(52.5\%)$ were male, 19 subjects$(47.5\%)$ were female, and the age distribution was from 19 to 70 in age, the average age was 52.7. By the classification of diagnosis, 21 subjects$(52.5\%)$ were cerebral hemorrhage, 8 subjects$(20.2\%)$ were cerebral thrombosis, 6 subjects$(15.0\%)$ were cerebral embolism, and 5 subjects$(12.5\%)$ were cerebral infarction. The Barthel Index scores were 35.7, 54.5, 71.8, 88.7 on the average at T1, T2, T3, T4 respectively. The PULSES scores were 16.4, 13.7, 11.4, 8.7 on the average at T1, T2, T3, T4 respectively. Regarding the Pearson's correlation coefficient between the Barthel Index scores and the PULSES scores, it was -0.7991(P>0.001) at T1 and -0.8986(P>0.001) at T3, then beth of correlations were very high.

  • PDF

The Study on the Improvement of Antireflection Coating Efficiency According to the Angle of Incidence (입사각에 따른 반사방지막 성능 개선에 관한 연구)

  • Kim, Chang-Bong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4131-4136
    • /
    • 2015
  • This paper compares and calculates more precisely the averaged reflectance of antireflection coating with different structure of single and 6 layer assuming the incident angle of light changing from $8^{\circ}$ to $60^{\circ}$ not like normal incidence as usual case. The reflectivity of AR coating of 6 layers with 180 nm thickness having index profile suggested as linear and quintic function and single layer with same thickness having even index are calculated and compared, when the wavelength of incident light ranges from 400 nm to 1200 nm. As the results the AR coating with 6 layers having quintic(linear) function index profile shows the lower reflectance about 11.6 %(14.6 %) than other index profiles, which is approximately 8 % lower reflectance compared with single layer case(about 19.6 %). This results could be applied for the better antireflection coating design applying to optical devices and filters.

Profile-based TRN/INS Integration Algorithm Considering Terrain Roughness (지형 험준도를 고려한 프로파일 기반 지형참조항법과 관성항법의 결합 알고리즘)

  • Yoo, Young Min;Lee, Sun Min;Kwon, Jay Hyun;Yu, Myeong Jong;Park, Chan Gook
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.2
    • /
    • pp.131-139
    • /
    • 2013
  • In recent years alternative navigation system such as a DBRN (Data-Base Referenced Navigation) system using geophysical information is getting attention in the military navigation systems in advanced countries. Specifically TRN (Terrain Referenced Navigation) algorithm research is important because TRN system is a practical DBRN application in South Korea at present time. This paper presents an integrated navigation algorithm that combines a linear profile-based TRN and INS (Inertial Navigation System). We propose a correlation analysis method between TRN performance and terrain roughness index. Then we propose a conditional position update scheme that utilizes the position output of the conventional linear profile type TRN depending on the terrain roughness index. Performance of the proposed algorithm is verified through Monte Carlo computer simulations using the actual terrain database. The results show that the TRN/INS integrated algorithm, even when the initial INS error is present, overcomes the shortcomings of linear profile-based TRN and improves navigation performance.

A Study on the Anti-Reflection Coating Effects of Polymer Eyeglasses Lens (폴리머 안경렌즈의 반사방지 코팅효과 연구)

  • Kim, Ki-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.216-221
    • /
    • 2017
  • Reducing optical reflection in the visible light range, in order to increase the share of transmitted light and avoid the formation of ghost images in imaging, is important for polymer lens applications. In this study, polymer lenses with refractive indices of n=1.56, 1.60, and 1.67 were fabricated by the injection-molding method with a polymer lens monomer, dibutyltin dichloride as the catalyst and an alkyl phosphoric ester as the release agent. To investigate their anti-reflection (AR) effects, various AR coating structures, viz. a multi-layer AR coating structure, tri-layer AR coating structure with a discrete approximation Gaussian gradient-index profile, and tri-layer AR coating structure with a quarter-wavelength approximation, were designed and coated on the polymer lens by an E-beam evaporation system. The optical properties of the polymer lenses were characterized by UV-visible spectrometry. The material properties of the thin films, refractive index and surface roughness, were analyzed by ellipsometry and AFM, respectively. The most effective AR coating structure of the polymer lens with low refractive index, n=1.56, was the both side coating of multi-layer AR coating structure. However, both side coating of the tri-layered discrete approximation Gaussian gradient-index profile AR coating structure gave comparable results to the both side coating of the multi-layer AR coating structure for the polymer lens with a high refractive index of n=1.67.

Derivation of the refractive index profile equation of K-Na ion-exchange waveguide by a rapid thermal method (급열법에 의한 K-Na 이온교환 도파로의 굴절율 분포식산출)

  • 강승민
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.237-241
    • /
    • 1990
  • A detailed theoretical and experimental study of k-na exchange in soda lime silicate glasses by RTP is presented. Concentration profiles i.e. index profiles are given by complementary error function added Gaussian function. The estimated diffusion coefficient is 1.54${\mu}{\textrm}{m}$2/min.

  • PDF

Customer Classification Method Using Customer Attribute Information to Generate the Virtual Load Profile of non-Automatic Meter Reading Customer (미검침 고객의 가상 부하패턴 생성을 위한 고객 속성 정보를 이용한 고객 분류 기법)

  • Kim, Young-Il;Ko, Jong-Min;Song, Jae-Ju;Choi, Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1712-1717
    • /
    • 2010
  • To analyze the load of distribution line, real LPs (Load Profile) of AMR (Automatic Meter Reading) customers and VLPs (Virtual Load Profile) of non-AMR customers are required. Accuracy of VLP is an important factor to improve the analysis performance. There are 2 kinds of methods to generate the VLP; one is using ALP (Average Load Profile) per each industrial code and PNN (Probability neural networks) algorithm; the other is using LSI (Load Shape Index) and C5.0 algorithm. In this paper, existing researches are studied, and new method is suggested. Each methods are compared the performance with same LP data of real high voltage customers.

Quality of Sleep and Serum Lipid Profile in Patients with Restless Legs Syndrome (하지불안증후군 환자의 수면의 질과 혈청지질 농도)

  • Bak, Yeon-Gyung;Park, Hyoung-Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.41 no.3
    • /
    • pp.344-353
    • /
    • 2011
  • Purpose: The purpose of this study was to compare the quality of sleep with the serum lipid profile in patients who have restless legs syndrome (RLS). Methods: The data were obtained from 116 patients with RLS through questionnaires and blood sampling. Results: The results of this study showed correlations between lower quality of sleep and serum lipid profile (LDL Cholesterol) in patients with RLS (r=.19, p=.040). There were correlations for scores of quality of sleep from the, Pittsburgh Sleep Quality Index (PSQI) sub-region between lower subjective sleep quality and serum lipid profile (LDL Cholesterol) (r=.20, p=.026), between fewer hours of sleep duration and serum lipid profile (Total Cholesterol) (r=-.21, p=.024), and, between higher daytime dysfunction and serum lipid profile (LDL Cholesterol) (r=.42, p<.001) of patients with RLS. Conclusion: Pati-ents with RLS have sleep disorders with lower quality of sleep and changes in the serum lipid profile for total cholesterol and LDL cholesterol. That is, patients with RLS have lower quality of sleep and dyslipidemia compared to persons without RLS. Further research is needed to monitor serum the lipid profile in early stage symptoms of midlife adult patients with RLS and especially older women.