• Title/Summary/Keyword: Incident rate

Search Result 333, Processing Time 0.025 seconds

The Dose Attenuation according to the Gantry Angle and the Photon Energy Using the Standard Exact Couch and the 6D Robotic Couch (Standard Exact Couch와 6D Robotic Couch를 이용한 광자선의 조사각에 따른 선량 감쇠에 대한 연구)

  • Kim, Tae Hyeong;Oh, Se An;Yea, Ji Woon;Park, Jae Won;Kim, Sung Kyu
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.79-85
    • /
    • 2016
  • The objective of this study is to increase the accuracy of dose transmission in radiation therapy using two types of treatment tables, standard exact couch (Varian 21EX, Varian Medical Systems, Milpitas, CA) and 6D robotic couch (Novalis, BrainLAB A.G., Heimstetten, Germany)). We examined the dose attenuation based on the two types of treatment tables and studied the dose of attenuation using the phase (In/Out) for the standard exact couch. We measured the relative dose according to the incident angle of a penetrative photon beam under a treatment table. The incident angle of the photon beam was from $0^{\circ}$ to $360^{\circ}$ in the increments of $5^{\circ}$. The reference angle was set to $0^{\circ}$. Furthermore, the relative dose of the 6D robotic couch was measured using 6 MV and 15 MV, and that of the standard exact couch was measured at the sliding rail position (In-Out) using 6 MV and 10 MV. In the case of the standard exact couch, the measured relative dose was 16.53% (rails at the "In position," $175^{\circ}$, 6 MV), 12.42% (rails at the "In position," $175^{\circ}$, 10 MV), 13.13% (rails at the "Out position," $175^{\circ}$, 6 MV), and 9.96% (rails at the "Out position," $175^{\circ}$, 10 MV). In the case of the 6D robotic couch, the measured relative dose was 6.82% ($130^{\circ}$, 6 MV) and 4.92% ($130^{\circ}$, 15 MV). The photon energies were surveyed at the same incident angle. The dose attenuation for an energy of 10 MV was 4~5% lower than that for 6 MV. This indicated that the higher photon energy, lesser is the attenuation. The results of this study indicated that the attenuation rate for the 6D robotic couch was confirmed to be 1% larger than that for the standard exact couch at 6 MV and $180^{\circ}$. In the case of the standard exact couch, the dose attenuation was found to change rapidly in accordance with the phase ("In position" and "Out position") of the sliding rail.

Effects of Jogihaeatag(調氣解瘀湯) on the Cerebral Cortex Neuron injured by XO/XA (조기해어탕(調氣解瘀湯)이 XO/XA에 의해 손상(損傷)된 대뇌피질(大腦皮質) 신경세포(神經細胞)에 미치는 영향(影響))

  • Lee Yong-Keun;Kang Hyung-Won;Lyu, Yeoung-Su
    • Journal of Oriental Neuropsychiatry
    • /
    • v.10 no.2
    • /
    • pp.29-45
    • /
    • 1999
  • As the average life span has been lengthened and the rate of senile population has been raised, chronic degenerative diseases incident to aging have been increased rapidly and become a social problem. With this social background, recently, oxygen radicals(OR) have toxic effects on Central Nervous System and Peripheral Nervous System and cause neuropathy such as Parkinson's Disease, Alzheimer Disease. The purpose of this study is to examine the toxic effects caused by Xanthine Oxidase(XO) and the effects of herbal extracts such as Jokihaeatang(JHT) on the treatment of the toxic effects. For this purpose, experiments with the cultured cell from the cerebrums of new born mice were done. The results of these experiments were as follows. 1. X0, an oxygen radical, decreased the survival rate of the cultured cells on NR assay, MTT assay and amount of neurofilaments and increased the amount of lipid peroxidation. 2. JHT have efficacy of increasing the amount of neurofilaments.

  • PDF

Implementation of Digital Directly Observed Treatment (DOT) System using a Smart Pillbox (스마트 약상자를 이용한 디지털 직접 복약 관리 시스템의 구축)

  • Kim, Beom-Joon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.5
    • /
    • pp.1213-1219
    • /
    • 2012
  • As Korea is expected to enter an aging society in near future, the number of patients who need a long-term prescribtion is expected to increase as well. In particular, Korea shows the highest in both the incident rate and the death rate among OECD member nations. The current situation requires more strict monitoring and management for patients' taking medicine, there are a few practical problems such as personnel expenses. Recently the concept of directly observed treatment (DOT) that is based on the IT technologies has been introduced. This paper, therefore, proposes a digital DOT system with a smart pillbox and drives key requirements for the smart pillbox that plays an important and essential role in the proposed digital DOT system.

An Approximation Method in Bayesian Prediction of Nuclear Power Plant Accidents (원자력 발전소 사고의 근사적인 베이지안 예측기법)

  • Yang, Hee-Joong
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.16 no.2
    • /
    • pp.135-147
    • /
    • 1990
  • A nuclear power plant can be viewed as a large complex man-machine system where high system reliability is obtained by ensuring that sub-systems are designed to operate at a very high level of performance. The chance of severe accident involving at least partial core-melt is very low but once it happens the consequence is very catastrophic. The prediction of risk in low probability, high-risk incidents must be examined in the contest of general engineering knowledge and operational experience. Engineering knowledge forms part of the prior information that must be quantified and then updated by statistical evidence gathered from operational experience. Recently, Bayesian procedures have been used to estimate rate of accident and to predict future risks. The Bayesian procedure has advantages in that it efficiently incorporates experts opinions and, if properly applied, it adaptively updates the model parameters such as the rate or probability of accidents. But at the same time it has the disadvantages of computational complexity. The predictive distribution for the time to next incident can not always be expected to end up with a nice closed form even with conjugate priors. Thus we often encounter a numerical integration problem with high dimensions to obtain a predictive distribution, which is practically unsolvable for a model that involves many parameters. In order to circumvent this difficulty, we propose a method of approximation that essentially breaks down a problem involving many integrations into several repetitive steps so that each step involves only a small number of integrations.

  • PDF

Effect of Horizontal Connection and Slope on Buckling Characteristics of Single Pipe (단관 파이프의 좌굴특성에 대한 수평연결재 및 기울기의 영향)

  • Lee, Jin Seop;Lee, Yeon Su;Oh, Tae Keun
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.2
    • /
    • pp.48-55
    • /
    • 2015
  • The number of collapse accidents relevant to form support since 2003 is 30 on the basis of statistical data from Ministry of Employment and Labor,. Total number of casualty was 138 (47 for deaths and 91 for injuries). The accident severity rate was high because the 4.6 casualties per one accident were occurred averagely although the incident rate was relatively low. Especially, one of form support members, the pipe supports have not been equipped adequately so that the accidents could have happened. In this regard, this study performed buckling test related to the effect of horizontal connection and slope in the single pipe which is one of typical pipe supports. The buckling load, which was estimated from the single pipe with the horizontal connectors theoretically and experimentally, was increased as more than 2 times compared to the buckling load obtained from the pipe supports without the connector. The buckling load was reduced as more than 26%, 34% slope of the single pipe comparing with 5% and 10% slope, respectively. Thus, the purpose of this study is to provide the guideline for installation and the maintenance of the pipe supports legally and institutionally to prevent the collapse accidents of the pipe supports.

A Study on the Shape of the Pattern Milled Using FIB (집속이온빔 연마에 의한 패턴의 형태에 관한 연구)

  • Jung, Won-Chae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.11
    • /
    • pp.679-685
    • /
    • 2014
  • For the measurements of surface shape milled using FIB (focused ion beam), the silicon bulk, $Si_3N_4/Si$, and Al/Si samples are used and observed the shapes milled from different sputtering rates, incident angles of $Ga^+$ ions bombardment, beam current, and target material. These conditions also can be influenced the sputtering rate, raster image, and milled shape. The fundamental ion-solid interactions of FIB milling are discussed and explained using TRIM programs (SRIM, TC, and T-dyn). The damaged layers caused by bombarding of $Ga^+$ ions were observed on the surface of target materials. The simulated results were shown a little bit deviation with the experimental data due to relatively small sputtering rate on the sample surface. The simulation results showed about 10.6% tolerance from the measured data at 200 pA. On the other hand, the improved analytical model of damaged layer was matched well with experimental XTEM (cross-sectional transmission electron microscopy) data.

Retrospective Study of Tracheal Collapse 99 Cases Diagnosed by Radiography in Dogs (2002-2003) (개에서 방사선학적으로 진단된 기관협착 발생 조사 99례 (2002-2003))

  • 이기창;송경진;최호정;허진영;정주현;장진화;윤정희;최민철
    • Journal of Veterinary Clinics
    • /
    • v.21 no.3
    • /
    • pp.276-279
    • /
    • 2004
  • Ninety-nine dogs diagnosed as tracheal collapse were reviewed for 2002-2003 year at Veterinary Medical Teaching Hospital, Seoul National University with clinical records and radiographs. Dogs were ranged in age from 1 to 15 years old (average 8.23 years old) and in weight from 1.2kg to 10.3kg (average 3.3kg). The population included 58 females (6 spayed) and 41 males (8 castrated). It is highly predominant in Yorkshire terrier (64, 64.6%) followed by Pomeranian (10, 10.1 %), Poodle and Chihuahua (8, 8.1%), Maltese (4, 4.0%), mixed breed (3, 3.0%), Cocker Spaniel and Pug (1, 1.0%). The incident rate of female dogs (59%) exhibited relatively higher than that of male dogs (41%). The most prevalent occurrence location was thoracic inlet (60%) of all and carina region (15%), intrathoracic trachea (14%) and cervical trachea (11 %) showed similar rate. Conclusively, tracheal collapse was observed in completely matured or old small breed dogs, largely Yorkshire terrier, on thoracic inlet primarily regardless of gender. These tendencies were apparently similar to previous reports.

Passively Q-switched Erbium Doped All-fiber Laser with High Pulse Energy Based on Evanescent Field Interaction with Single-walled Carbon Nanotube Saturable Absorber

  • Jeong, Hwanseong;Yeom, Dong-Il
    • Current Optics and Photonics
    • /
    • v.1 no.3
    • /
    • pp.203-206
    • /
    • 2017
  • We report a passive Q-switching of an all-fiber erbium-doped fiber laser delivering high pulse energy by using a high quality single-walled carbon nanotube saturable absorber (SWCNT-SA). A side-polished fiber coated with the SWCNT is employed as an in-line SA for evanescent wave interaction between the incident light and the SWCNT. This lateral interaction scheme enables a stable Q-switched fiber laser that generates high pulse energy. The central wavelength of the Q-switched pulse laser was measured as 1560 nm. A repetition rate frequency of the Q-switched laser is controlled from 78 kHz to 190 kHz by adjusting the applied pump power from 124 mW to 790 mW. The variation of pulse energy from 51 nJ to 270 nJ is also observed as increasing the pump power. The pulse energy of 270 nJ achieved at maximum pump power is 3 times larger than those reported in Q-switched all-fiber lasers using a SWCNT-SA. The tunable behaviors in pulse duration, pulse repetition rate, and pulse energy as a function of pump power are reported, and are well matched with theoretical expectation.

MODEL CALCULATIONS OF THE UV - EXCITED MOLECULAR HYDROGEN IN INTERSTELLAR CLOUDS

  • Lee, Dae-Hee;Pak, Soo-Jong;Seon, Kwang-Il
    • Publications of The Korean Astronomical Society
    • /
    • v.20 no.1 s.24
    • /
    • pp.7-10
    • /
    • 2005
  • We have calculated 2448 interstellar cloud models to investigate the formation and destruction of high rotational level $H_2$ according to the combinations of five physical conditions: the input UV intensity, the $H_2$ column density, cloud temperature, total density, and the $H_2$ formation rate efficiency. The models include the populations of all the accessible states of $H_2$ with the rotational quantum number J < 16 as a function of depth through the model clouds, and assume that the abundance of $H_2$ is in a steady state governed primarily by the rate of formation on the grain surfaces and the rates of destruction by spontaneous fluorescent dissociation following absorption in the Lyman and Werner band systems. The high rotational levels J = 4 and J = 5 are both populated by direct formation into these levels of newly created molecules, and by pumping from J = 0 and J = 1, respectively The model results show that the high rotational level ratio N(4)/N(0) is proportional to the incident UV intensity, and is inversely proportional to the $H_2$ molecular fraction, as predicted in theory.

Characteristics of Alpha Particle Track on Cellulose Nitrate Film (Cellulose Nitrate의 알파입자비적특성(粒子飛跡特性))

  • Do, Jin-Yeol;Jun, Jae-Shik;Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.2
    • /
    • pp.61-66
    • /
    • 1984
  • A study on the characteristics of ${\alpha}$-particle track on cellulose nitrate film was carried out with a particular emphasis on the dependence of track diameter upon chemical etching condition. The track diameters etched in KOH solution appeared to be, on average, three times larger than those etched in NaOH under the same etching condition. The relationship between the track diameters and both etching time and the energy of incident ${\alpha}$-particles was also investigated. It is shown that the particle fluence rate is fairly independent of etching time as far as the condition of irradiation remains unchanged.

  • PDF