• Title/Summary/Keyword: In-situ application

Search Result 566, Processing Time 0.03 seconds

Application of in-situ CaCO3 forming process on recycled fibers for optical property improvement (고지의 광학적특성 개선을 위한 in-situ 탄산칼슘처리기술의 적용)

  • Park, Dong-Hui;Lee, Min-Woo;Lee, Jong-Kyu;Ahn, Ji-Whan;Seo, Yung-Bum
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.4
    • /
    • pp.8-15
    • /
    • 2012
  • Optical property improvements for ONP (old newspaper) and OMG (old magazine) were attempted by application of in-situ $CaCO_3$ formation process on recycled fiber surfaces. Washing treatment of ONP and OMG resulted in 35~40% yield loss for around 6% brightness improvement. Washing plus bleaching process with $H_2O_2$ and FAS (formamidine sulfinic acid) improved brightness and ERIC values a little more with the same amount of yield loss as washing treatment. In-situ $CaCO_3$ formation method improved those optical properties much better than the washing plus bleaching method without loss of yield, and better than the case of adding high brightness PCC up to the same ash level. It can be said that the in-situ $CaCO_3$ formation method may be used as an effective alternative for upgrading optical properties of recycled fibers.

In-situ Application of Glossy Architectural Concrete (광택노출콘크리트의 현장 기술)

  • 정태웅;이현희;하재담;강창운
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.836-839
    • /
    • 1999
  • Glossy architectural concrete means high qulity concrete which develops marble-like gloss on the surface of concrete. In spite of many benefits of architectural concrete to R.C. structure such as appearance of natural stone, saving of envelope materials and reduction of building weight, the failure of in-situ application of architectural concrete by the absence of knowledge on the physical properties and form work for it can often be found in Korea. This study is to offer the basic materials on the mix proportion, vibrating, curing and treatment of concrete result from the mock up test and in-situ application of architectural concrete to embody high quality architectural concrete in Korea.

  • PDF

Concrete Pavement for the Access Road using Recycled Concrete Aggregate Crushed in-situ (현장파쇄 재생골재를 사용한 부체도로 콘크리트 포장)

  • Shim Jae Won;Kim Jin Cheol;Jo Kyu Seong;Choi Kang Sick
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.348-351
    • /
    • 2004
  • In this study, the recycled concrete aggregates crushed in-situ were used for the access road pcc (portland cement concrete) pavement. Based on laboratory results, the properties of materials, mixture proportioning, blend rates, and application conditions were investigated prior to trial application, and the various problems on recycled concrete aggregate under construction have been comprehensively checked.

  • PDF

Application of in situ gelling mucoadhesive delivery system for plasmid DNA as a macromolecule

  • Park, Jeong-Sook;Oh, Yu-Kyoung;Kim, Chong-Kook
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.236.1-236.1
    • /
    • 2002
  • Mucosal administration of drug or therapeutic gene is emerging as a new route of delivery for systemic and local therapeutics. Previously. in situ gelling system has been applied to chemical drug such as acetaminophen. insulin. prostaglandin E1. and clotrimazole. Plasmid DNA has not been delivered in form of in situ gelling vehicles. To improve the intranasal absorption of plasmid DNA. we designed delivery systems composed of provide of in 냐셔 gelling and mucoadhesive polymers. (omitted)

  • PDF

Application of In Situ Measurement for Site Remediation and Final Status Survey of Decommissioning KRR Site

  • Hong, Sang Bum;Nam, Jong Soo;Choi, Yong Suk;Seo, Bum Kyoung;Moon, Jei Kwon
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.173-178
    • /
    • 2016
  • Background: In situ gamma spectrometry has been used to measure environmental radiation, assumptions are usually made about the depth distribution of the radionuclides of interest in the soil. The main limitation of in situ gamma spectrometry lies in determining the depth distribution of radionuclides. The objective of this study is to develop a method for subsurface characterization by in situ measurement. Materials and Methods: The peak to valley method based on the ratio of counting rate between the photoelectric peak and Compton region was applied to identify the depth distribution. The peak to valley method could be applied to establish the relation between the spectrally derived coefficients (Q) with relaxation mass per unit area (${\beta}$) for various depth distribution in soil. The in situ measurement results were verified by MCNP simulation and calculated correlation equation. In order to compare the depth distributions and contamination levels in decommissioning KRR site, in situ measurement and sampling results were compared. Results and Discussion: The in situ measurement results and MCNP simulation results show a good correlation for laboratory measurement. The simulation relationship between Q and source burial for the source layers have exponential relationship for a variety depth distributions. We applied the peak to valley method to contaminated decommissioning KRR site to determine a depth distribution and initial activity without sampling. The observed results has a good correlation, relative error between in situ measurement with sampling result is around 7% for depth distribution and 4% for initial activity. Conclusion: In this study, the vertical activity distribution and initial activity of $^{137}Cs$ could be identifying directly through in situ measurement. Therefore, the peak to valley method demonstrated good potential for assessment of the residual radioactivity for site remediation in decommissioning and contaminated site.

Application of Real-Time Monitoring System to In-Situ Soil Remediation Project (원위치 지반오염정화사업에서의 실시간 모니터링 시스템의 적용 사례)

  • Jung, Seung-Yong;Kim, Byung-Il;Han, Sang-Jae;Kim, Soo-Sam;Hong, Sang-Ki
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1384-1389
    • /
    • 2005
  • A real-time monitoring system for in-situ soil remediation technologies is developed and then applied to electrokinetic remediation technique in the field trial tests during 150days. The developed system is consisted the controlled program based on internet web page, data logger, measurement instruments and so on. In the measured items there are pH, temperature, electrical current and potential, vacuum pressure. The results indicated that the system is successively applied to electrokinetic remediation technique, and further research considering economic view and multi purpose system for in-situ soil remediation technologies is needed.

  • PDF

Epitaxial growth of in-situ doped polycrystalline 3C-SiC for M/NEMS application (M/NEMS용 in-situ 도핑된 다결정 3C-SiC 박막 성장)

  • Kim, Kang-San;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.18-19
    • /
    • 2008
  • Polycrystalline(poly) 3C-SiC film is a promising structural material for M/NEMS used in harsh environments, bio and fields. In order to realize poly 3C-SiC based M/NEMS devices, the electrical properties of poly 3C-SiC film have to be optimized. The n-type poly 3C-SiC thin film is deposited by APCVD using HMDS$(Si_2(CH_3)_6)$ as single precursor and are in-situ doped using N2. Resistivity values as low as 0.014 $\Omega$cm were achieved. The carrier concentration increased with doping from $3.0819\times10^{17}$ to $2.2994\times10^{19}cm^{-3}$ and electronicmobility increased from 2.433 to 29.299 $cm^2/V{\cdot}s$.

  • PDF

In Situ Rescue Bypass for Iatrogenic Avulsion of Parent Artery during Clipping Large Pericallosal Artery Aneurysm

  • Park, Jae-Chan;Kang, Dong-Hun
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.1
    • /
    • pp.68-70
    • /
    • 2009
  • A case of large aneurysm arising from the distal end of an azygous A2 segment is presented. Multiple clip application inadvertently tore the aneurysmal neck, resulting in near avulsion of a right pericallosal artery origin. After an unsuccessful attempt to repair the avulsion, it was treated by occlusion of the origin of the pericallosal artery and an A4-A4 anterior cerebral artery in situ bypass without neurological deficits. The surgical technique and previous reports onside-to-side in situ bypass are discussed.

Developing 500 MHz NB 19F-13C Double Resonance Solid-State NMR Probe for in-situ Analysis of Liquid Crystal Display Panels

  • Choi, Sung-Sub;Jung, Ji-Ho;Park, Yu-Geun;Park, Tae-Joon;Park, Gregory Hyung-Jin;Kim, Yong-Ae
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.5
    • /
    • pp.1577-1580
    • /
    • 2012
  • The orientational and dynamic behavior of liquid crystal molecules on the alignment layer surfaces of liquid crystal display (LCD) devices is crucial to their performance, but there are only a few methods of experimentally elucidating the interactions between the liquid crystals and the alignment layers. Inspired by the natural and technical similarities between membrane proteins in lipid bilayers and liquid crystals in LCDs, we employed solid-state NMR methodologies originally developed for the study of membrane proteins in lipid bilayers for the in-situ analysis of liquid crystal display panels. In this article, we present a home-built 500 MHz narrowbore (NB) The orientational and dynamic behavior of liquid crystal molecules on the alignment layer surfaces of liquid crystal display (LCD) devices is crucial to their performance, but there are only a few methods of experimentally elucidating the interactions between the liquid crystals and the alignment layers. Inspired by the natural and technical similarities between membrane proteins in lipid bilayers and liquid crystals in LCDs, we employed solid-state NMR methodologies originally developed for the study of membrane proteins in lipid bilayers for the in-situ analysis of liquid crystal display panels. In this article, we present a home-built 500 MHz narrowbore (NB) $^{19}F-^{13}C$ double resonance solid-state NMR probe with a flat-square coil and the first application of this probe for the in-situ analysis of LCD panel samples. double resonance solid-state NMR probe with a flat-square coil and the first application of this probe for the in-situ analysis of LCD panel samples.