• 제목/요약/키워드: Impulse testing

검색결과 94건 처리시간 0.027초

Elastic modulus in large concrete structures by a sequential hypothesis testing procedure applied to impulse method data

  • Antonaci, Paola;Bocca, Pietro G.;Sellone, Fabrizio
    • Structural Engineering and Mechanics
    • /
    • 제26권5호
    • /
    • pp.499-516
    • /
    • 2007
  • An experimental method denoted as Impulse Method is proposed as a cost-effective non-destructive technique for the on-site evaluation of concrete elastic modulus in existing structures: on the basis of Hertz's quasi-static theory of elastic impact and with the aid of a simple portable testing equipment, it makes it possible to collect series of local measurements of the elastic modulus in an easy way and in a very short time. A Hypothesis Testing procedure is developed in order to provide a statistical tool for processing the data collected by means of the Impulse Method and assessing the possible occurrence of significant variations in the elastic modulus without exceeding some prescribed error probabilities. It is based on a particular formulation of the renowned sequential probability ratio test and reveals to be optimal with respect to the error probabilities and the required number of observations, thus further improving the time-effectiveness of the Impulse Method. The results of an experimental investigation on different types of plain concrete prove the validity of the Impulse Method in estimating the unknown value of the elastic modulus and attest the effectiveness of the proposed Hypothesis Testing procedure in identifying significant variations in the elastic modulus.

HVDC 케이블용 XLPE 절연 재료에 대한 DC/Impulse 중첩실험 시스템 구축 (Build-up of DC/Impulse Superposition Testing System for XLPE materials in HVDC cables)

  • 김정태;김동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1608-1609
    • /
    • 2011
  • In this study, in order to develop the evaluation method for XLPE materials for HVDC cables, DC/Impulse superposition testing system was builded up. Throughout the P-spice simulation, optimal values of the protection resistor for the DC generation system and the blocking capacitor for the Impulse generator were calculated. DC/Impulse superposition system showed good result maintaining their proper wave shapes and amplitudes. This system would be planned to apply to the evaluation of XLPE materials for HVDC cables.

  • PDF

Cost Effective Design of High Voltage Impulse Generator and Modeling in Matlab

  • Javid, Zahid;Li, Ke-Jun;Sun, Kaiqi;Unbreen, Arooj
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1346-1354
    • /
    • 2018
  • Quality of the power system depends upon the reliability of its components such as transformer, transmission lines, insulators, circuit breakers and isolators. The transient voltage due to internal or external reasons may affect the insulation level of the components. The insulation level of these components must be tested against these conditions. Different studies, testing of different electrical components against high voltage impulses and different industrial applications rely on the international manufactures for pulsed power generation and testing, that is quite expensive and large in size. In this paper a model of impulse voltage generator with capacitive load of pin type insulator is studied by simulation method and by an experimental setup. A ten stage high voltage impulse generator (HVIG) is designed and implemented for different applications. In this proposed model, the cost has been reduced by using small and cheap capacitors as an alternative for large and expensive ones while achieving the same effectiveness. Effect of the distributed capacitance in each stage is analyzed to prove the effectiveness of the model. Different values of front and tail resistances have been used to get IEC standard waveforms. Results reveal the effectiveness at reduced cost of the proposed model.

도로동공 탐지에 적합한 GPR 타입 선정에 관한 연구 (A Study on the Selection of GPR Type Suitable for Road Cavity Detection)

  • 김연태;최지영;김기덕;박희문
    • 한국도로학회논문집
    • /
    • 제19권5호
    • /
    • pp.69-75
    • /
    • 2017
  • PURPOSES : The purpose of this study is to evaluate different types of Ground Penetrating Radar (GPR) testing for characterizing the road cavity detection. The impulse and step-frequency-type GPR tests were conducted on a full-scale testbed with an artificial void installation. After analyzing the response signals of GPR tests for detecting the road cavity, the characteristics of each GPR response was evaluated for a suitable selection of GPR tests. METHODS : Two different types of GPR tests were performed to estimate the limitation and accuracy for detecting the cavities underneath the asphalt pavement. The GPR signal responses were obtained from the testbed with different cavity sizes and depths. The detection limitation was identified by a signal penetration depth at a given cavity for impulse and step-frequency-type GPR testing. The unique signal characteristics was also observed at cavity sections. RESULTS : The impulse-type GPR detected the 500-mm length of cavity at a depth of 1.0 m, and the step-frequency-type GPR detected the cavity up to 1.5 m. This indicates that the detection capacity of the step-frequency type is better than the impulse type. The step-frequency GPR testing also can reflect the howling phenomena that can more accurately determine the cavity. CONCLUSIONS :It is found from this study that the step-frequency GPR testing is more suitable for the road cavity detection of asphalt pavement. The use of step-frequency GPR testing shows a distinct image at the cavity occurrences.

충격 햄머 실험에서 다자유도 주파수 응답 스펙트럼의 개선 (An Enhancement of Multi-Dof Frequency Response Spectrum from Impact Hammer Testing)

  • Ahn, Se-Jin;Jeong, Weui-Bong
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.363.2-363
    • /
    • 2002
  • The spectrum of impulse response signal from an impulse hammer testing is widely used to obtain frequency response function(FRF) of the structure. However the FRFs obtained from impact hammer testing have not only leakage errors but also finite record length errors when the record length for the signal processing is not sufficiently long. The errors cannot be removed with the conventional signal analyzer which treats the signals as if they are always steady and periodic. (omitted)

  • PDF

지수창함수를 사용한 임팩트햄머 실험에서 주파수응답함수의 왜곡과 개선책 (FRF Distortion Caused by Exponential Window Function on Impact Hammer Testing and Its Solution)

  • 안세진;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제13권5호
    • /
    • pp.334-340
    • /
    • 2003
  • Exponential window function Is widely used In impact hammer testing to reduce leakage error as well as to get a good S/N ratio. The larger its decaying rate is, the more effectively the leakage errors are reduced. But if the decay rate of the exponential window is too large, the FRF is distorted. And the modal parameters of the system can not be exactly identified by modal analysis technique. Therefore, it is a difficult problem to determine proper decay rate in impact hammer testing. In this paper, amount of the FRF distortion caused by exponential window is theoretically uncovered. A new circle fitting method is also proposed so that the modal parameters are directly extracted from impulse response spectrum distorted by the exponential-windowed impulse response data. The results by the conventional and proposed circle fitting method are compared through a numerical example.

충격량에 의한 고장메커니즘을 활용한 추간체유합보형재의 신뢰성 평가 방법 및 개선에 관한 연구 (A Research on the Reliability Assessment and Improvement of Spinal Cage using by the Failure Mechanism by the Impulse)

  • 유우진;이용윤;허성용;함중걸
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제14권4호
    • /
    • pp.243-247
    • /
    • 2014
  • The Spinal cage is the cage-shaped implantable medical device used to treat structural abnormalities caused by degenerative intervertebral disks. In order to secure enough space to provide the mechanical stability and the intervertebral fusion, after removing the intervertebral disc, the Spinal cage is transplanted between the intervertebral space. A hammer is used to push the spinal cage into a narrow space during the spinal cage transplant surgery. Due to the impact and pressure, damage occurs frequently on the spinal cage. In this study, a test model is constructed to measure the value of impulse generally applied on the Spinal cage. The figures of internal impulse before and after the improvement of the Spinal cage are then compared to suggest direction to improve the reliability of the spinal cage.

시간 정의구역 Born 근사에 의한 탄성매질에서의 결함에 관한 연구 (Characterization of Flaws in the Elastic Medium by Time Domain Born Approximation)

  • 이재열;이세경;이재옥;김영환
    • 비파괴검사학회지
    • /
    • 제3권1호
    • /
    • pp.5-11
    • /
    • 1983
  • The impulse response function are studied using time domain Born approximation in two cases; firstly when the material parameters of a flaw are constant, secondly when the parameters are varying with positions. From the impulse response functions, characteristics can be learned about a flaw with high symmetry.

  • PDF

충격햄머 가진으로 구한 주파수응답함수의 오차와 해결방법 (The errors and reducing method in the frequency response function from impact hammer testing)

  • 안세진;정의봉
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.71-77
    • /
    • 2002
  • The spectrum of impulse response signal which is obtained from an impulse hammer testing is used for frequency response function, nevertheless it has serious faults when the record length for the signal processing is not very long. The faults cannot be avoided with the conventional signal analyzer that is processing all the signals as if they are always periodic. The signals generated by the impact hammer are undoubtedly non-periodic because of the damping, and are acquired for limited recording time due to the memory as well as the computation performance of the signal analyzer. This paper will make clear the relation between the faults and the length of recording time, and propose the way for solving the faults.

  • PDF

22.9kV-Y 다중접지 배전계통 접지극의 임펄스 응답 특성 실증연구 (A Study On the Impulse Response Behavior of Ground Rods in Power Distribution System)

  • 강문호;장상옥;박상만;하동혁;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1858-1860
    • /
    • 2003
  • Ground rods as the discharge path are commonly installed to ensure the safety of human beings and facilities from the surge. Accordingly, proper grounding resistance are specified by the grounding types, and the specified resistance are also required to install the lightning protective facilities. it is needed to analyze the difference between these two resistance through the field test. Therefore, in this paper, the impulse response behavior of the ground rods is analyzed by constructing the test facilities and by testing the ground rods in multi-ground power distribution systems. The impulse responses were analyzed, in transient state, by testing the concrete poles as well since the grounding wires are installed in the concrete poles.

  • PDF