• Title/Summary/Keyword: Implantable sensors

Search Result 46, Processing Time 0.017 seconds

Wearable and Implantable Sensors for Cardiovascular Monitoring: A Review

  • Jazba Asad;Jawwad Ibrahim
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.7
    • /
    • pp.171-185
    • /
    • 2023
  • The cardiovascular syndrome is the dominant reason for death and the number of deaths due to this syndrome has greatly increased recently. Regular cardiac monitoring is crucial in controlling heart parameters, particularly for initial examination and precautions. The quantity of cardiac patients is rising each day and it would increase the load of work for doctors/nurses in handling the patients' situation. Hence, it needed a solution that might benefit doctors/nurses in monitoring the improvement of the health condition of patients in real-time and likewise assure decreasing medical treatment expenses. Regular heart monitoring via wireless body area networks (WBANs) including implantable and wearable medical devices is contemplated as a life-changing technique for medical assistance. This article focuses on the latest development in wearable and implantable devices for cardiovascular monitoring. First, we go through the wearable devices for the electrocardiogram (ECG) monitoring. Then, we reviewed the implantable devices for Blood Pressure (BP) monitoring. Subsequently, the evaluation of leading wearable and implantable sensors for heart monitoring mentioned over the previous six years, the current article provides uncertain direction concerning the description of diagnostic effectiveness, thus intending on making discussion in the technical communal to permit aimed at the formation of well-designed techniques. The article is concluded by debating several technical issues in wearable and implantable technology and their possible potential solutions for conquering these challenges.

Triboelectric Nanogenerators for Self-powered Sensors

  • Rubab, Najaf;Kim, Sang-Woo
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.79-84
    • /
    • 2022
  • Self-powered sensors play an important role in everyday life, and they cover a wide range of topics. These sensors are meant to measure the amount of relevant motion and transform the biomechanical activities into electrical signals using triboelectric nanogenerators (TENGs) since they are sensitive to external stimuli such as pressure, temperature, wetness, and motion. The present advancement of TENGs-based self-powered wearable, implantable, and patchable sensors for healthcare monitoring, human body motion, and medication delivery systems was carefully emphasized in this study. The use of TENG technology to generate electrical energy in real-time using self-powered sensors has been the topic of considerable research among various leading scholars. TENGs have been used in a variety of applications, including biomedical and healthcare physical sensors, wearable devices, biomedical, human-machine interface, chemical and environmental monitoring, smart traffic, smart cities, robotics, and fiber and fabric sensors, among others, as efficient mechanical-to-electric energy conversion technologies. In this evaluation, the progress accomplished by TENG in several areas is extensively reviewed. There will be a discussion on the future of self-powered sensors.

Current Development in Bio-implantable Sensors

  • Swarup, Biswas;Yongju, Lee;Hyojeong, Choi;Hyeok, Kim
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.403-410
    • /
    • 2022
  • Flexible and wearable sensing technologies have emerged as a result of developments in interdisciplinary research across several fields, bringing together various subjects such as biology, physics, chemistry, and information technology. Moreover, various types of flexible wearable biocompatible devices, such customized medical equipment, soft robotics, bio-batteries, and electronic skin patches, have been developed over the last several years that are extensively employed to monitor biological signals. As a result, we present an updated overview of new bio-implantable sensor technologies for various applications and a brief review of the state-of-the-art technologies.

Battery Power Switching System for Implantable Telemetry Systems (체내 삽입 텔리메터리 시스템용 전원 스위칭 시스템 개발)

  • Seo, Hee-Don
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1990 no.11
    • /
    • pp.118-121
    • /
    • 1990
  • This paper describes development of an implantable power switching system for biotelemetry system. This system is designed and manufactured to achieve as small size and low power dissipation as possible, using pulse powered circult and CMOS technology. The function of the power switching system is to connect the implantable battery to implanted sensors and, electronics systems by receiving intermittent command signals from external circuits. The power dissipation of this system was about $15{\mu}W$ for a stand-by operation.

  • PDF

A Study On the Automatic Cardiac Output Control Without Pressure Sensors for the motor-driven Totally Implantable TAH Using Motor-Current Waveform Analysis (모터구동형 완전이식 인공심장에서 전류파형의 분석에 의한 심박출량 자동제어 알고리즘의 개발)

  • Choe, Won-U;Kim, Hui-Chan;Min, Byeong-Gu
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.11
    • /
    • pp.130-135
    • /
    • 1992
  • In this paper a new cardiac output control method without pressure sensors is presented for the rotor-driven totally implantable TAH using motor-current wavelet analysis. Theoretical analysis and mock circulation system experiment results show that cardiac output of TAH, which is indeperdent of afterload and sensitively dependent to preload, is well controlled for the independently variable preload.

  • PDF

Self-powered Sensors based on Piezoelectric Nanogenerators

  • Rubab, Najaf;Kim, Sang-Woo
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.293-300
    • /
    • 2022
  • Flexible, wearable, and implantable electronic sensors have started to gain popularity in improving the quality of life of sick and healthy people, shifting the future paradigm with high sensitivity. However, conventional technologies with a limited lifespan occasionally limit their continued usage, resulting in a high cost. In addition, traditional battery technologies with a short lifespan frequently limit operation, resulting in a substantial challenge to their growth. Subsequently, utilizing human biomechanical energy is extensively preferred motion for biologically integrated, self-powered, functioning devices. Ideally suited for this purpose are piezoelectric energy harvesters. To convert mechanical energy into electrical energy, devices must be mechanically flexible and stretchable to implant or attach to the highly deformable tissues of the body. A systematic analysis of piezoelectric nanogenerators (PENGs) for personalized healthcare is provided in this article. This article briefly overviews PENGs as self-powered sensor devices for energy harvesting, sensing, physiological motion, and healthcare.

Manufacture of Custom IC and System for Multi-channel Biotelemeter (다채널 바이오텔레미터 개발을 위한 전용 IC 및 시스템 제작)

  • 서희돈;박종대
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.8
    • /
    • pp.172-180
    • /
    • 1994
  • Implantable biotelemetry systems are indispensable tools not only in animal research but also in clinical medicine as such systems enable the acquisition of otherwise unavailable physiological data. We present the manufacture of CMOS IC and its system for implantable multichannel biotelemeter system. The internal circuits of this system are designed not only to achieve as multiple functions and low power dissipation as possible but also to enable continuous measurement of physiological data. Its main functions are to enable continuous measurement of physiological data and to accomplish on-off power swiching of an implantable battery by receiving appropriate commanc signals from an external circuit. The implantable circuits of this system are designed and fabricated on a single silicon chip using $1.5\mu$m n-well CMOS process technology. The total power dissipation of implantable circuits for a continuous operation was 6.7mW and for a stand-by operation was 15.2$\mu$ W. This system used together with approriate sensors is expected to contribute to clinical medicine telemetry system of measuring and wireless transmitting such significant physiological parameters as pressure pH and temperature.

  • PDF

Proposition of a New Implantable Acoustic Sensor Based on Technology Evaluation of Fully Implantable Hearing Aids (완전 이식형 보청기 기술 평가 기반의 새로운 이식형 음향센서 제안)

  • Cho, Jin-Ho;Woo, Seong Tak;Lim, Hyung-Gyu;Jung, Eui Sung;Lee, Jyung Hyun;Lee, Seung-Ha;Seong, Ki Woong
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.178-184
    • /
    • 2014
  • Key components of implantable hearing aids are consist of an acoustic sensor that collect external sound by suppressing the body noise, a signal processor module for compensation algorithm of hearing loss, and a output transducer which has tiny size but have high efficiency, respectively. In the partial implantable hearing aids, technologies of transducer and signal processor are so matured that can be applied not too much difficulty. However, due to the difficulties in implantable acoustic sensor technology, such as minimization of masticatory sound and damage of sensor's membrane from external impact, practical use of fully implantable hearing aids have not successful so far. In this paper, we have proposed a novel implantable acoustic sensor which has trans-tympanic structure, and is verified that the proposed method can be very useful for fully implantable hearing aids by cadaveric experiments.

Design and Fabrication of Implantable LC Resonant Blood Pressure Sensor (인체 삽입용 LC 공진형 혈압 센서 디자인 및 제작)

  • Kim, Jin-Tae;Kim, Sung Il;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.3
    • /
    • pp.171-176
    • /
    • 2013
  • In this paper, we present a MEMS (micro-electro-mechanical system) implantable blood pressure sensor which has designed and fabricated with consideration of size, design flexibility, and wireless detection. Mechanical and electrical characterizations of the sensor were obtained by mathematical analysis and computer aided simulation. The sensor is composed of two coils and a air gap capacitor formed by separation of the coils. Therefore, the sensor produces its resonant frequency which is changed by external pressure variation. This frequency movement is detected by inductive coupling between the sensor and an external antenna coil. Theoretically analyzed resonant frequency of the sensor under 760 mmHg was calculated to 269.556 MHz. Fused silica was selected as sensor material with consideration of chemical and electrical reaction of human body to the material. $2mm{\times}5mm{\times}0.5mm$ pressure sensors fitted to radial artery were fabricated on the substrates by consecutive microfabrication processes: sputtering, etching, photolithography, direct bonding and laser welding. Resonant frequencies of the fabricated sensors were in the range of 269~284 MHz under 760 mmHg pressure.

Development of a transcutaneous system for implantable bio-signal measurement (생체신호계측을 위한 체내 이식형 무선송수신 시스템 개발)

  • Lee, Seung-Ha
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.23-28
    • /
    • 2008
  • In order to measure bio-signals, it is desirable to build a fully implantable system which connects directly to neural pathways or body tissue. A design scheme for fully implementable measurement system is proposed in this paper. Consisting of an implanted module and an external system, the proposed scheme delivers power and data between the two modules. The external module sends power via inductive link using a simple H-bridge type oscillator. Also, the implanted module sends measured data to the external system utilizing R/F communication technique at a frequency of ISM band. A stable communication and operation is achieved as the two types of channels are separated. Implemented in a compact size enough to be implanted in human body, the system exhibits good performance in experimental studies.