• 제목/요약/키워드: Implant Patient

검색결과 990건 처리시간 0.026초

불량한 치조제에서의 임플랜트 시술증례 (IMPLANT REHABILITATION IN THE UNFAVORABLE ALVEOLAR RIDGE)

  • 박재범;안상헌;정수일;조병완;안재진
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제19권1호
    • /
    • pp.35-44
    • /
    • 1997
  • The most critical factor in determining which type of implant to be used would be the available bone of the patient. Usually a minimum of 5mm in the bone width and 8mm in the bone height is necessary to ensure primary implant stability and maintain the integrity of bone contact surface. Placement of implant is limited by the several anatomic strutures such as maxillary sinus, floor of the nose, inferior alveolar neurovascular bundle and nasopalatine foramen, etc. When severe resorption of alveolar ridge is encountered, implant placement would be a problematic procedure. A number of techniques to improve the poor anatomic situations have been proposed. This article reports 4 cases of patients using surgical procedures such as blade implant technique, cortical split technique in the anterior maxillary area, sinus lifting and lateral repositioning of inferior alveolar nerve, We treated dental implant candidates with unfavorable alveolar ridge utilizing various surgical techniques, resulted in successful rehabilitation of edentulous ridge.

  • PDF

Splinted or Non-splinted: 다수의 인접한 치아 결손부 수복을 위한 임플란트 보철 (Splinted and non-splinted implant-supported restorations : prosthetic considerations for restoring multiple adjacent teeth)

  • 윤형인
    • 대한치과의사협회지
    • /
    • 제54권3호
    • /
    • pp.198-205
    • /
    • 2016
  • The purpose of this paper was to investigate the significance of splinted and non-splinted implant-supported restorations with an internal connection for multiple consecutively missing teeth. Upon examination of the effects of fixture-abutment connection, the distribution of occlusal load was favorable in splinted implant-prosthesis with an external connection, but effect of strain distribution was not significant in splinted implant-prosthesis with an internal connection. In splinted implant-prostheses for short implants, strain distribution was not affected by the method of retention. For cement-retained prostheses, the effect of strain distribution due to splinting was not significant. In clinical studies, non-splinted prostheses with an internal connection for multiple consecutively missing teeth showed high survival rate, mild marginal bone loss, and stable periodontal condition. However, failure to achieve optimal proximal contact between single-unit prostheses may lead to food impaction, and veneer fracture may be inevitable when the framework provides inadequate support in the proximal region. In conclusion, splinted implant-prosthesis is not an indication in all cases, and clinical consideration of its use should be based on the patient's oral condition, such as location and number of implants, formation of proximal contact, canine guidance, existence of parafunctional habit, and oral hygiene, when multiple consecutively missing teeth are replaced by internal connection type implant.

  • PDF

Early implant failure: a retrospective analysis of contributing factors

  • Kang, Dae-Young;Kim, Myeongjin;Lee, Sung-Jo;Cho, In-Woo;Shin, Hyun-Seung;Caballe-Serrano, Jordi;Park, Jung-Chul
    • Journal of Periodontal and Implant Science
    • /
    • 제49권5호
    • /
    • pp.287-298
    • /
    • 2019
  • Purpose: The aim of this retrospective study was to determine the prevalence of early implant failure using a single implant system and to identify the factors contributing to early implant failure. Methods: Patients who received implant treatment with a single implant system ($Luna^{(R)}$, Shinhung, Seoul, Korea) at Dankook University Dental Hospital from 2015 to 2017 were enrolled. The following data were collected for analysis: sex and age of the patient, seniority of the surgeon, diameter and length of the implant, position in the dental arch, access approach for sinus-floor elevation, and type of guided bone regeneration (GBR) procedure. The effect of each predictor was evaluated using the crude hazard ratio and the adjusted hazard ratio (aHR) in univariate and multivariate Cox regression analyses, respectively. Results: This study analyzed 1,031 implants in 409 patients, who comprised 169 females and 240 males with a median age of 54 years (interquartile range [IQR], 47-61 years) and were followed up for a median of 7.2 months (IQR, 5.6-9.9 months) after implant placement. Thirty-five implants were removed prior to final prosthesis delivery, and the cumulative survival rate in the early phase at the implant level was 95.6%. Multivariate regression analysis revealed that seniority of the surgeon (residents: aHR=2.86; 95% confidence interval [CI], 1.37-5.94) and the jaw in which the implant was placed (mandible: aHR=2.31; 95% CI, 1.12-4.76) exerted statistically significant effects on early implant failure after adjusting for sex, age, dimensions of the implant, and type of GBR procedure (preoperative and/or simultaneous) (P<0.05). Conclusions: Prospective studies are warranted to further elucidate the factors contributing to early implant failure. In the meantime, surgeons should receive appropriate training and carefully select the bone bed in order to minimize the risk of early implant failure.

확장성(더블루멘) 보형물을 이용한 유방확대술 (Breast Augmentation using Expandable Implants)

  • 심형보;남상재;윤상엽
    • Archives of Plastic Surgery
    • /
    • 제32권4호
    • /
    • pp.416-420
    • /
    • 2005
  • Ideal results of augmentation mammaplasty consist of symmetry, natural shape, soft feeling and inconspicuous scar. In addition, patient's preferences about size and shape should be included. Static implants could not perfectly satisfy patients' desires for size and shape, but expandable implants enable to change the volume after the operation. From September 2001 to September 2004, 76 patients(150 breasts) underwent breast augmentation using permanent expandable implant. The procedure was unilateral in 2 women and bilateral in 74 women. Age ranged from 19 to 50 years(mean, 29 years). Fifty nine patients underwent simple augmentation mammaplasty, 7 patients were corrected of their severe asymmetry, 2 patients with the congenital breast deformity underwent mammaplasty using this, and 2 patients who had undergone unilateral mastectomy were reconstructed of their breasts using expandable implant. There were no definite complications such as capsular contracture, implant rupture, asymmetry. And there reported little dissatisfaction about the size. The permanent expandable implants might be good alternatives in cases of ordinary breast augmentation as well as tissue deficient patients, asymmetry, congenital anomaly, and breast reconstruction.

심미가 중요시되는 임플란트 치료시 타이타늄 링크-캐드캠 지르코니아 지대주 사용의 임상적 고려 (Clinical considerations of use of titanium link - CAD/CAM zirconia abutment for dental implant in esthetically important areas)

  • 김종엽
    • 대한치과의사협회지
    • /
    • 제54권2호
    • /
    • pp.123-133
    • /
    • 2016
  • Currently increasing use of implants, especially in anterior implant esthetics has become a major concern for both the patient and dentist. In the case of thin biotype if the thickness of the gingival soft tissue is less than 2mm, human eye can detect differences of colors depends on underlying materials. The zirconia abutment can be use not only for better esthetics but also for the hygienic because it is less attractive for the plaque deposition when it compare to the metals. Zirconia itself has many advantages as a biomaterial but also has frequent mechanical problems when it use for abutment of internal connection implant. For prevention or reduction of mechanical failures, use of titanium-link with zirconia super-structure which part that connects directly into the implant can be a good alternative. In this literature, I would like to review the clinical considerations of use of titanium link - CAD/CAM zirconia abutment for dental implant in esthetically important areas.

  • PDF

임프란트 지지 국소의치의 임상적 연구 (Clinical study of implant supported removable partial dentures)

  • 박원희
    • 대한치과의사협회지
    • /
    • 제47권4호
    • /
    • pp.184-190
    • /
    • 2009
  • OBJECTIVE The purpose of clinical study was to evaluate the survival of dental implants used in restoring patients with implant supported removable partial dentures (ISRPDs) of different configurations. MATERIALS AND METHODS The sample consisted of 20 consecutively treated partially edentulous patients, who, between 2003 and 2008, had a total of 84implants placed in different arch sites and who were treated with ISRPDs. The mean age was 57 years. Mean follow up time from delivery of ISRPDs was 3 years 2 months (range, 1 to 6 years). Osseointegration failure, postoperative complication of dental prosthesis, and the success rate of ISRPDs were retrospectively evaluated using clinical and radiographic examination. RESULT The overall implant survival rate was 100%. During follow up, the one clasp of removable partial denture was broken in 1 year11 months after prosthesis delivery. All patients were satisfied with their prosthesis. CONCLUSIONS Implant supported removable partial dentures could serve as favorable prognosis. Careful patient selection, with an appropriate maintenance and recall system, is recommended to obtain satisfactory results.

  • PDF

Bisphosphonate를 복용하는 환자에게 임프란트 치료시 고려사항 (Considerations during dental implant treatment for patients under bisphosphonate therapy)

  • 박원서;정원윤;김형준;김기덕
    • 대한치과의사협회지
    • /
    • 제49권7호
    • /
    • pp.389-397
    • /
    • 2011
  • Bisphosphonate inhibits the function of osteoclast, so they are widely used for multiple myeloma, Paget's disease, metastatic malignant bone disease, and severe osteoporosis. This drug is very effective for preventing severe complication of osteoporosis, some unpredictable complication occurred such as esophageal malignancy, atypical fracture of femur, and osteonecrosis of the jaw. Bisphosphonate related osteonecrosis of the jaw (BRONJ) is closely related with invasive, open bone surgery like tooth extraction. BRONJ associated with dental implant is rare, however, as the use of bisphosphonate increase, BRONJ cases with dental implant are increasing. In this article, we will describe the considerations during dental implant treatment for patient under bisphosphonate therapy.

Immediate implant placement in fresh extraction sockets

  • Lee, Won
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제47권1호
    • /
    • pp.57-61
    • /
    • 2021
  • Immediate implant placement (IIP) in fresh extraction sockets exhibits similar survival and success rates to delayed implant placement in healed sockets. Several advantages of IIP involve shortened total treatment time, reduction of the number of invasive surgeries, and subsequent reduction of patient discomfort due to lack of additional surgeries. The major shortcomings in IIP, however, include the inability to obtain early bony support, presence of a gap between the extraction socket and fixture, and the inability to cover the fixture with soft tissue, leading to increased risk of infection and implant loss. When IIP is performed, atraumatic or minimally traumatic extractions, conservation of the septal bone in molars, minimal flap elevation or flapless surgery, bone grafting the gap between the fixture and the extraction socket, and coverage with soft tissue or a membrane must be considered.

타임스케줄을 이용한 임플란트 수술의 지연 개선 (Prevention of delay in implant services using time schedule)

  • 박지연
    • 대한치과의료관리학회지
    • /
    • 제10권1호
    • /
    • pp.1-8
    • /
    • 2022
  • This study introduces research on the quality of medical services, optimization of medical services, dental medical services, implant medical services, and time schedules, as well as the effective process of dental implant medical services, which is expensive and requires a long treatment period. For improvement, it is suggested to evaluate using a time schedule. In this method, a time schedule is prepared in which each step, starting from the patients appointment until the completion of the treatment process, is allotted a certain time. This schedule was finalized in consultation with the employees. When performing all implant operations, the starting time of each item was checked to evaluate the degree of compliance and to understand any reasons for delay in each step. After identifying the causes for delay at each step, suitable steps to rectify the drawbacks were developed, and an optimal plan for patient management was determined. Changes in waiting time and human resource utilization were shown as concrete data, suggesting that such a schedule is meaningful as a decision-making support tool.