Due to rapidly increased urbanization, impervious area has been extended and concerns about urban flooding has been increased as well. A lot of effort has been made to restore the urban water circulation. Low Impact Development (LID) technology that consist of retention, infiltration, and evapotranspiration has begun to attract attention to simulate the hydrologic phenomenon before and after development. Many researches on the technique is being actively conducted. In this study, the effect on reducing runoff in urban catchment was analyzed and evaluated by applying LID techniques using SWMM and six scenarios. A SWMM-LID model was built for the Gasan 1 rainwater pumping station basin, and Green Roof and Permeable Pavement were selected as LID techniques to be applied. As a result, the reduction effect of the permeable pavement was larger than green roof. In the future, the results could be used to design a LID facility using the characteristics of the watershed, and other urban water resource factors such as river and groundwater levels that affect each other should be considered, so that the entire system can be considered.
Koo, Young Min;Jo, Jae An;Kim, Young Do;Park, Jae Hyeon
KSCE Journal of Civil and Environmental Engineering Research
/
v.33
no.2
/
pp.559-571
/
2013
Recently, due to increase of the impervious layer, the storage of surface layer has been reduced. Otherwise the peak runoff and the total surface runoff have been raised. Because of larger amount of the peak runoff and the rapid time of concentration, the flood damage of the urban watershed was increased. The groundwater level is descended by reducing the amount of rainfall that infiltrated into the soil. Thereby the hydrologic cycle is degenerated by the dry stream. Therefore, in this study, the evaluation and the quantitative analysis of the percolation effect were performed through the infiltration experiment of permeable pavement, which is one of the ways that can reduce the problem of the dry stream. Also the SWMM model is used to analyze the effect of the hydrologic cycle for permeable pavement in Changwon stream and Nam stream watersheds, with the coefficient of permeability from the infiltration experiments.
Impervious surface increase due to urbanization, one of the leading causes of pavement increased the runoff coefficient, peak flow, and reducing the infiltration flow and thereby causing flooding and river erosion is occurring in aquatic ecosystems are known to impair. This study aimed to classify use type of detailed land into the road, reststop, tollgates and etc. focused on major domestic highways, to understand the characteristics of rainfall runoff pollutants and to calculate applicable unit pollution load. Because of high runoff coefficient and short travel time to drainage. first flush occurred clearly. Average EMCs of runoff in the highway was investigated as TSS 108.47 mg / L, COD 28.16 mg / L, BOD 13.61 mg / L, TN 6.38 mg / L, TP 0.03 mg / L, Cu 118.17 ${\mu}g$ / L, Pb 345.3 ${\mu}g$ / L, Zn 349.47 ${\mu}g$ / L. Unit pollution loads calculated by detailed land use area of highways based on average annual rainfall, EMCs, applicable basin areas and etc. were 46.6 kg/km2/day of BOD, 1.4 kg/km2/day of TP, 8.81 kg / km2/day of TN and these were BOD 50.8%, TP 66.7%, TN 64.4%in comparison of the unit pollution loads which applies fallow land standards of the TMDL(Total Maximum Daily Load). It was considered that discharged loads can be excessively calculated in case highway non-point management plans based on unit pollution load of the current land standard.
Park, Jaerock;Kim, Jaemoon;Baek, Jongseok;Seo, Youngjae;Shin, Hyunsuk
Journal of Korea Water Resources Association
/
v.55
no.11
/
pp.969-977
/
2022
In order to respond to the increase in water disasters due to climate change and urbanization, research on low impact development (LID) techniques and application to cities are expanding. The LID technique is a technology that reduces rainwater runoff in the city, controls various water disasters such as flash floods, etc. in an eco-friendly way, and restores the urban water circulation system to a natural water circulation system. However, quantitative analysis of stormwater runoff reduction through the LID technique is insufficient. Therefore, this study analyzed the ratio of the permeable area required to reduce the surface runoff of rainfall (25 mm/hr, 50 mm/hr, 100 mm/hr) with respect to the impervious watershed area of the old city using the permeable pavement. As a result of the analysis, it was found that a permeable area ratio of 7.14 to 12.63% of the total area was required for 25 mm/hr, 15.79 to 26.97% for 50 mm/hr, and 30 to 55.81% for 100 mm/hr.
Impervious covers(IC) are artificial structures, such as driveways, sidewalks, building's roofs, and parking lots, through which water cannot infiltrate into the soil. IC is an environmental concern because the pavement materials seal the soil surface, decreasing rainwater infiltration and natural groundwater recharge, and consequently disturb the hydrological cycle in a watershed. Increase of IC in a watershed can cause more frequent flooding, higher flood peaks, groundwater drawdown, dry river, and decline of water quality and ecosystem health. There has been an increased public interest in the institutional adoption of LID(Low Impact Development) and GI(Green Infrastructure) techniques to address the adverse impact of IC. The objectives of this study were to construct the modeling site for a samll urban watershed with the Storm Water Management Model(SWMM), and to evaluate the effect of various LID techniques on the control of rainfall runoff processes and non-point pollutant load. The model was calibrated and validated using the field data collected during two flood events on July 17 and August 11, 2009, respectively, and applied to a complex area, where is consist of apartments, school, roads, park, etc. The LID techniques applied to the impervious area were decentralized rainwater management measures such as pervious cover and green roof. The results showed that the increase of perviousness land cover through LID applications decreases the runoff volume and pollutants loading during flood events. In particular, applications of pervious pavement for parking lots and sidewalk, green roof, and their combinations reduced the total volume of runoff by 15~61 % and non-point pollutant loads by TSS 22~72 %, BOD 23~71 %, COD 22~71 %, TN 15~79 %, TP 9~64 % in the study site.
Andong belongs to the Nakdong River Basin, Nakdong River is flowing through the city, including Andong dam and Imha dam. The runoff due to provincial transfer and impervious area has been increasing by urbanization increases and nonpoint source loads. In this study, we evaluate the runoff and nonpoint pollution loads in accordance with the development targeted at selected urban water cycle leading to Andong city. Andong city leading to the water cycle plan to evaluate the directly runoff and BOD, T-N and T-P nonpoint pollutant loads using the CN into account the temporal and spatial changes. Evaluation, direct runoff per year is 10.41 % if the green roof and a water permeable pavement replacement, water cycle parks and streets compositions, City impermeable layer improvements to be business including four kinds of scenario is applied to both the development and the BOD non-point pollutant loads 20.56%, T-N 9.55% and T-P pollution and nonpoint loads was investigated to be reduced 14.29%. Four kinds of low lapse rate of the development scenario of the highest thing urban impervious surface was investigated by improving business development prior year annual direct runoff is 6.25 %, BOD nonpoint pollution loads are 11.84%, T-N nonpoint pollution loads are 4.46 % and T-P was investigated by reducing pollutant loads to be 10.20%.
Porous pavements are recommended as a Low-Impact Development (LID) method which is a strategy to develop a water cycle as close to a natural state as possible, and to solve the urban impervious surface problems. Porous pavements can yield a solution if it provides a more permeable surface with extra space to contain extra water from building roofs. But there are few applications in Korea because of a lack of recognition and experience. Highway engineers are mainly concerned about the infiltration of water into pavement structures. They worry about the weakening of the asphalt mixture and subgrade, and freezing during the winter season due to the infiltration of water. Meanwhile, hydrological experts doubt the effects of the amount of water to control during the flooding season, and environmental experts prefer a non-point pollution treatment system established beside highway. In this study, from reviewing the history and the body of literature about porous pavements, conclusions regarding the most advanced technologies were made. First, traditional thickness designs can be used for porous pavement, no extra distresses was found by weakening and freezing during the winter season. Second, hydrological design can be made by controlling the thickness of the pavement and the outlet of water. Third, the treatment efficiency of non-point pollution of porous pavements is not worse than any other method. Importantly, it's a more eco-friendly solution because of its lower requirement for de-icing agents.
Jo, Seon-Ah;Hong, Eun-Soo;Cho, Gye-Chun;Jin, Kyu-Nam;Lee, Jung-Min;Han, Shin-In
Journal of Korean Tunnelling and Underground Space Association
/
v.18
no.1
/
pp.95-107
/
2016
Ground water is one of important parameters in the designs of underpass structures because urban areas are characterized by soil ground which is relatively permeable than rock ground and a high level of ground water due to low elevation. Therefore, it is important properly to predict variations of the ground water when they can affect underpass structures. In this study, a series of numerical analyses are performed to predict the variations of ground water levels considering the degree of surface imperviousness and LID(Low Impact Development) application. In turn the stability of underground structure is assessed using predicted ground water level. The results show that an increase in the impervious surface area decreases the ground water level. The application of permeable pavement as a LID facility increases the ground water level, improving the infiltration capacity of rainfall into the ground. Seasonal variations of the ground water level are also verified in numerical simulation. The results of this study suggest that reasonable designs of underpass structures can be obtained with the suitable prediction and application of the ground water level considering the surface characteristics.
Kim, Byungsung;Lim, Seokhwa;Lee, Sangjin;Baek, Jongseok;Kim, Jaemoon
Journal of Korean Society on Water Environment
/
v.36
no.2
/
pp.109-115
/
2020
Recently, since impervious areas have increased due to urban development, the water cycle system of urban watersheds has been destructed. Hence, researches on LID (Low Impact Development) technique have been conducted to solve such problems environmentally. In order to verify suitability with the scale and arrangement of LID technique, the runoff reduction effect of the LID technique should be analyzed per small watershed unit. In this study, pre-post difference of the runoff by applying the LID was estimated using the rational method and rainwater treatment capacity equation. As a result, the runoff before and after the application of LID were estimated as 22,533.5 ㎥ and 14,992.1 ㎥, respectively. In addition, rainfall-runoff simulations were carried out using SWMM to evaluate the efficiency of the LID technique. The SWMM simulation results showed that the runoff before and after the application of LID were 21,174 ㎥ and 15,664 ㎥, respectively. Based on the results of the two methods, the scale and arrangement of the LID technique were revised in order to maximize the effect of the water cycle improvement. Rainfall-runoff simulations were carried out using the SWMM with the revised LID techniques. As a result, despite 34.8 % reduction of pervious pavement area, the rate of runoff reduction increased by 2.1 %. These results indicate that designing the scale and arrangement of LID technique, while considering the total amount of inflow entering into each LID techniques, is essential to effectively achieve the goals of runoff reduction in urban development.
Journal of the Korean Society of Environmental Restoration Technology
/
v.17
no.6
/
pp.61-72
/
2014
We implemented ecological linkage assessment, through the connection components of the urban forests, rivers and parks, for the ecological connection of the urban parks which are standing out as the core of the urban green networks, so as to suggest basic data to compare, evaluate and improve urban green networks, as a basic study for the evaluation of the ecological connectabilities between the cities. For the ecological linkage assessment, we analyzed to see if the urban parks of Goyang, Ansan and Yongin, which are the subject cities, are actually ecologically connected with forests and rivers, using distance and roads, which are physical connection elements, in consideration of the mobility of the wild animals, and greening ratios and impervious pavement ratios, which are ecological connectabilities in consideration of the ecological values. The overall result of the ecological linkage assessment the physical connection elements and the ecological connection elements shows that the ecological green network ratio through direct connection states is 36.62% in Goyang, 42.55% in Ansan and 64.00% in Yongin, respectively, giving the ecological connectability ratio of less than half, with the average urban ecological green network ration of 47.72%. The comparison result of the ecological connectabilities between the object cities employing the connection elements indicates that when you set up green networks, you should consider together the physical connection elements, such as the roads, which will lower the ecological connectabilities - rather than do it simply based on areas and distances - while the ecological connection elements with the forests and the streams should be reinforced, so that the ecological connectabilities of the urban parks may be enhanced.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.