• Title/Summary/Keyword: Impedance tube

Search Result 139, Processing Time 0.028 seconds

Effects of Air-Dried Leaves of Evergreen Broad-Leaved Trees on Sound Absorption Property

  • JUNG, Su-Young;KONG, Ree-Keun;LEE, Kwang-Soo;BYEON, Hee-Seop
    • Journal of the Korean Wood Science and Technology
    • /
    • v.49 no.5
    • /
    • pp.482-490
    • /
    • 2021
  • This research was conducted to analyze the sound absorption effect of air-dried leaves from two evergreen tree species found in Korea's warm-temperate and subtropical regions. As eco-friendly sound absorption materials, Dendropanax morbiferusa, and Fatsia japonica leaves were prepared in three specimen units sizes 0.5 × 0.5 cm2, 1.0 × 1.0 cm2, and 2.0 × 2.0 cm2, and each of them was formed at a thickness of 1.00 cm, 1.75 cm, and 2.50 cm. The measured sound absorption coefficients (SAC) for 18 conditions were comparatively analyzed in this study. The SAC of both tree species was significantly improved by increasing the dried leaf layer thickness. These results showed a more consistent and distinct trend for both tree species under the condition of 0.5 cm2 in dried leaf size compared to other leaf specimen sizes. However, as the thickness increased, the difference in sound absorption effect according to the leaf size tends to decrease overall. In the case of D. morbiferus, there was no significant difference in SAC based on leaf size under the condition of 2.5 cm thickness (p < 0.05). The highest mean SAC was found in a 2.5 cm thick condition with a leaf size of 0.5 × 0.5 cm2, 0.549 for D. morbiferusa, and 0.594 for F. japonica, respectively.

A Study On Design of ZigBee Chip Communication Module for Remote Radiation Measurement (원격 방사선 측정을 위한 ZigBee 원칩형 통신 모듈 설계에 대한 연구)

  • Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.552-558
    • /
    • 2014
  • This paper suggests how to design a ZigBee-chip-based communication module to remotely measure radiation level. The suggested communication module consists of two control processors for the chip as generally required to configure a ZigBee system, and one chip module to configure a ZigBee RF device. The ZigBee-chip-based communication module for remote radiation measurement consists of a wireless communication controller; sensor and high-voltage generator; charger and power supply circuit; wired communication part; and RF circuit and antenna. The wireless communication controller is to control wireless communication for ZigBee and to measure radiation level remotely. The sensor and high-voltage generator generates 500 V in two consecutive series to amplify and filter pulses of radiation detected by G-M Tube. The charger and power supply circuit part is to charge lithium-ion battery and supply power to one-chip processors. The wired communication part serves as a RS-485/422 interface to enable USB interface and wired remote communication for interfacing with PC and debugging. RF circuit and antenna applies an RLC passive component for chip antenna to configure BALUN and antenna impedance matching circuit, allowing wireless communication. After configuring the ZigBee-chip-based communication module, tests were conducted to measure radiation level remotely: data were successfully transmitted in 10-meter and 100-meter distances, measuring radiation level in a remote condition. The communication module allows an environment where radiation level can be remotely measured in an economically beneficial way as it not only consumes less electricity but also costs less. By securing linearity of a radiation measuring device and by minimizing the device itself, it is possible to set up an environment where radiation can be measured in a reliable manner, and radiation level is monitored real-time.

A Study for the Norms of Audiometric Tests in Koreans (정상한국인의 청력검사치에 관한 연구)

  • 오혜경;서장수;이근해;김희남;김영명;권영화;서옥기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.38.1-38
    • /
    • 1981
  • Currently in the otologic field, there are various methods of special audiometric examinations, such as, tone decay, SISI, and impedance audiometry and only a few studies has been done in these fields sporadically in Korea. The purpose of this paper is to establish norms of various special audiometric tests, so we have performed the special audiometric tests on 100 male medical students in good physical condition and the follow results were obtained. 1. All cases showed over 90% of PB scores. The mean and its 2 S.D. were 98$\pm$4.9% in the right ear and 97$\pm$5.6% in the left ear. 2. The mean and its 2 S.D. of MCL(most comfortable level) were 45$\pm$15.4 dB in the right ear and 46$\pm$17.9 dB in the left ear, and its range was 12$\pm$12.2 dB in the right ear and 13$\pm$12.6 dB in the left ear. 3. The mean and its 2 S.D. of UCL (uncomfortable level) were 102$\pm$7.9 dB in the right ear and 102$\pm$7.9 dB in the left ear and about an half in cases showed over 106 dB of UCL. 4. In 95% of cases, SISIs(short increment sensitivity index) at 1, 000 Hz and 4000 Hz was below 45% in the right ear in both frequencies and below 55% and 75% in the left ear, respectively. 5. In 95% of cases, tone decays at 2, 000 Hz and 4, 000 Hz was below 10 dB in both ears. 6. The difference between SRT and PTA (speech reception threshold minus pure tone average) was 4$\pm$9.2 dB in the right ear and 4$\pm$10.0 dB in the left ear. 7. The dynamic range(uncomfortable level minus speech reception threshold) was 98$\pm$13.5 dB in the right ear and 99$\pm$13.5 dB in the left ear. We had trouble in estimating the dynamic range in about an half in cases, in which we couldn't estimate the UCL with our conventional audiometry. 8. The results of impedance audiometric tests were as follow: A. In the tympanogram, all cases were of A type with one exception of B type in the left ear. The mean and its 2 S.D. of its peak level were 22.8$\pm$32.94mm $H_2O$ in the right ear and 23.9$\pm$29. 81mm $H_2O$ in the left ear. B. The mean and its 2 S.D. of the compliance were 0.6$\pm$0.54cc in the right ear and 0.6$\pm$0.53cc in the left ear. C. The results of stapedial reflex: a. The mean and its 2 S.D. of the controlateral stapedial reflex at 500Hz, 1, 000Hz, 2, 000Hz, 4, 000Hz were 99$\pm$17.7 dB, 87$\pm$14.4 dB, 79$\pm$13.7 dB, 77$\pm$20.0 dB in the right ear and 99$\pm$15.9 dB, 88$\pm$13.9 dB, 79$\pm$13.7 dB, 77$\pm$21.3 dB in the left ear. Depending on the tested frequencies, the stapedial reflex wasn't generated in 6 cases in the right ear and 11 cases in the left ear. b. The mean and its 2 S.D. of the ipsilateral stapedial reflex at 1, 000Hz, and 2, 000Hz were 89$\pm$16.3 dB, 82$\pm$15.9 dB in the right ear and 89$\pm$18.0 dB, 83$\pm$18.9 dB in the left ear. Depending on the tested frequencies, the stapedial reflex wans't generated in 1 case in the right ear and 2 cases in the left ear. 9. Eustachian tube function using with impedance audiometry was malfunctioned in21 cases depending on the tested pressure and the range of peak level of tympanogram was 14$\pm$26.9mm $H_2O$(tested pressure:+250mm $H_2O$), 8$\pm$21.9mm $H_2O$ (tested pressure:-250mm $H_2O$) in the right ear and 11 cases depending on the tested pressure and the range of the peak level of tympanogram was 12$\pm$22.5mm $H_2O$ (tested pressure: +250 mm $H_2O$, 9$\pm$17.3mm $H_2O$(tested pressure: -250mm $H_2O$) in the left ear.

  • PDF

A Study on Organic-Inorganic Hybrid Sound Absorbing Materials Using by Recycling Gypsum (재활용 석고 부산물을 이용한 유무기 하이브리드 흡음재 개발 연구)

  • Shin, Hyun-Gyoo;Jeon, Bo-Ram;Ha, Joo-Yeon;Jeon, Chan-Soo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.4
    • /
    • pp.481-487
    • /
    • 2017
  • The purpose of this study is to develop the hybrid sound-absorbing materials that is made from organic polyurethane sponge impregnated with inorganic binder solutions. The inorganic slurry which is made from ${\alpha}$-hemihydrate gypsum mixed with 60% water, and various additives including plasticizer are used as binder. The test specimens are prepared and tested for sound absorption performance by the impedance tube methods. From the test results, noise reduction coefficient(NRC) of development materials specimen bound by the inorganic binder slurry is 0.41. They are 2 times or more higher than commercial products specimens bound by organic materials only which have NRC values in the range of 0.14 to 0.28. The polyurethane sponge specimens impregnated with inorganic gypsum slurry binder have a good balance between performance and cost, and have proper properties in density, thermal conductivity, non-combustible, and absence of harmful substances as sound-absorbing internal boards for noise barrier wall. It is apparent that the good sound absorption materials can be produced according to the optimum mix design that is recommended from this study.

Classification of Axis-symmetric Flaws with Non-Symmetric Cross-Sections using Simulated Eddy Current Testing Signals (모사 와전류 탐상신호를 이용한 비대칭 단면을 갖는 축대칭 결함의 형상분류)

  • Song, S.J.;Kim, C.H.;Shin, Y.K.;Lee, H.B.;Park, Y.W.;Yim, C.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.510-517
    • /
    • 2001
  • This paper describes an initial study for the application of eddy current pattern recognition approaches to more realistic flaw characterization in steam generator tubes. For this purpose, finite-element model-based theoretical eddy current testing (ECT) signals are simulated from 5 types of OD flaws with the variation in flaw size parameters and testing frequency. In addition, three kinds of software are developed for the convenience in the application of steps in pattern recognition approaches such as feature extraction feature selection and classification by probabilistic neural networks (PNNs). The cross point of the ECT signals simulated from flaws with non-symmetric cross-sections shows the deviation from the origin of the impedance plane. New features taking advantages of this phenomenon are added to complete the feature set with a total of 18 features. Then, classification with PNNs are performed based on this feature set. The PNN classifiers show high performance for the identification of symmetry in the cross-section of a flaw. However, they show very limited success in the interrogation of the sharpness of flaw tips.

  • PDF

Characteristics of Anode-supported Flat Tubular Solid Oxide Fuel Cell (연료극 지지체식 평관형 고체산화물 연료전지 특성 연구)

  • Kim Jong-Hee;Song Rak-Hyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.2
    • /
    • pp.94-99
    • /
    • 2004
  • Anode-supported flat tubular solid oxide fuel cell (SOFC) was investigated to increase the cell power density. The anode-supported flat tube was fabricated by extrusion process. The porosity and pore size of Ni/YSZ ($8mol\%$ yttria-stabilized zirconia) cermet anode were $50.6\%\;and\;0.23{\mu}m$, respectively. The Ni particles in the anode were distributed uniformly and connected well to each other particles in the cermet anode. YSZ electrolyte layer and multilayered cathode composed of $LSM(La_{0.85}Sr_{0.15})_{0.9}MnO_3)/YSZ$ composite, LSM, and $LSCF(La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.7}O_3)$ were coated onto the anode substrate by slurry dip coating, subsequently. The anode-supported flat tubular cell showed a performance of $300mW/cm^2 (0.6V,\; 500 mA/cm^2)\;at\;500^{\circ}C$. The electrochemical characteristics of the flat tubular cell were examined by ac impedance method and the humidified fuel enhanced the cell performance. Areal specific resistance of the LSM-coated SUS430 by slurry dipping process as metallic interconnect was $148m{\Omega}cm^2\;at\;750^{\circ}C$ and then decreased to $148m{\Omega}cm^2$ after 450hr. On the other hand, the LSM-coated Fecralloy by slurry dipping process showed a high area specific resistance.

A study on in-flight acoustic load reduction in launch vehicle fairing by FE-SEA hybrid method (FE-SEA 하이브리드 기법을 이용한 비행 중 발사체 페어링 내부 음향하중 저감에 관한 연구)

  • Choi, Injeong;Park, Seoryong;Lee, Soogab
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.4
    • /
    • pp.351-363
    • /
    • 2020
  • Launch vehicles are subject to airborne acoustic loads during atmospheric flight and these effects become pronounced especially in transonic region. As the vibration due to the acoustic loads can cause malfunction of payloads, it is essential to predict and reduce the acoustic loads. In this study, a complete process has been developed for predicting airborne vibro-acoustic environment inside the payload pairing and subsequent noise reduction procedure employing acoustic blankets and Helmholtz resonators. Acoustic loads were predicted by Reynolds-Averaged Navier-Stokes (RANS) analysis and a semi-empirical model for pressure fluctuation inside turbulent boundary layer. Coupled vibro-acoustic analysis was performed using VA One SEA's Finite Element Statistical Energy Analysis (FE-SEA) hybrid module and ANSYS APDL. The process has been applied to a hammerhead launch vehicle to evaluate the effect of acoustic load reduction and accordingly to verify the effectiveness of the process. The presently developed process enables to obtain quick analysis result with reasonable accuracy and thus is expected to be useful in the initial design phase of a launch vehicle.

Characteristics and Implications of Lava Tubes from Geophysical Exploration in Jeju Island (지구물리 탐사에 의해 발견된 제주도 용암동굴의 특징과 의미)

  • Jeon, Yongmun;Ki, Jin Seok;Koh, Su Yeon;Kim, Lyoun;Ryu, Choon Kil
    • The Journal of Engineering Geology
    • /
    • v.25 no.4
    • /
    • pp.473-484
    • /
    • 2015
  • Geophysical exploration using electric resistivity, ground penetrating radar (GPR), and impedance high-frequency (ZHF) surveys was conducted in Gujwa-eup, Jeju City, Jeju Island, an island in the Korea Strait, to confirm the existence of new caves near known caves. The exploration revealed a number of anomaly zones, presumed to be caves; 27 sites at suitable locations and depth ranges were selected for drilling and further surveys. However, contrary to predictions, most of the anomaly zones were clinker layers or paleosols intercalated with lavas. Only five boreholes intersected caves. The clinker layers and paleosols were possibly detected as anomalies owing to their different physical properties from the other rocks. Two of the five cave-finding boreholes penetrated Yongcheon Cave; a new cave was found at the other. The two boreholes that penetrated Yongcheon Cave were drilled in areas where the cave has not been previously reported, and thus helped correct an error in the cave distribution map. The cave newly discovered in this boring exploration is 180 m long, and it is connected to the upstream part of Dangcheomul Cave (110 m). The cave contains well-developed lava helictites, lava levees, and ropy structures; carbonate speleothems such as soda straws, stalagmites, columns, and curtain shawls are also well preserved. Notably, the unique shape of the carbonate speleothems is attributed to their growth in relation to the cavern water that flowed into the cave along plant roots.

Development of a Multichannel Eddy Current Testing Instrument(I) (다중채널 와전류탐상검사 장치 개발(I))

  • Lee, Hee-Jong;Nam, Min-Woo;Cho, Chan-Hee;Yoon, Byung-Sik;Cho, Hyun-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.2
    • /
    • pp.155-161
    • /
    • 2010
  • Recently, the electromagnetic techniques of the eddy current testing(ECT), alternating current field testing, magnetic flux leakage testing and remote field testing have been used as a nondestructive evaluation method based on the electromagnetic induction. The eddy current testing is now widely accepted as a NDE method for the heat exchanger tube in the electric power industry, chemical, shipbuilding, and military. The ECT system mainly consists of the synthesizer module, analog module, analog-to-digital converter, power supplier, and data acquisition and analysis program. In this study, the synthesizer module and the analog module which are essential to the ECT system were primarily developed. The developed ECT system is basically a multifrequency type which is able to inject the maximum four frequencies based on the frequency and time domain multiplexing method. Conclusively, we confirmed that the EC signal was processed appropriately in each circuit modules, and the Lissajous EC signal was displayed in the impedance plane.