• 제목/요약/키워드: Impedance Head

검색결과 48건 처리시간 0.026초

Transient Analysis and Leakage Detection Algorithm using GA and HS algorithm for a Pipeline System

  • Kim Sang-Hyun;Yoo Wan-Suk;Oh Kwang-Jung;Hwang In-Sung;Oh Jeong-Eun
    • Journal of Mechanical Science and Technology
    • /
    • 제20권3호
    • /
    • pp.426-434
    • /
    • 2006
  • The impact of leakage was incorporated into the transfer functions of the complex head and discharge. The impedance transfer functions for the various leaking pipeline systems were also derived. Hydraulic transients could be efficiently analyzed by the developed method. The simulation of normalized pressure variation using the method of characteristics and the impulse response method shows good agreement to the condition of turbulent flow. The leak calibration could be performed by incorporation of the impulse response method with Genetic Algorithm (GA) and Harmony Search (HS). The objective functions for the leakage detection can be made using the pressure-head response at the valve, or the pressure-head or the flow response at a certain point of the pipeline located upstream from the valve. The proposed method is not constrained by the Courant number to control the numerical dissipation of the method of characteristics. The limitations associated with the discreteness of the pipeline system in the inverse transient analysis can be neglected in the proposed method.

송전선로 주변의 3차원 자기장 및 인체 유도 와전류 계산 (ELF 3D Magnetic Field and Eddy Current Calculation of Human Body Around Transmission Lines)

  • 명성호;이동일;신구용;한인수;박종근
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권10호
    • /
    • pp.485-491
    • /
    • 2002
  • Since Wertheimer and Leeper reported possible adverse health effects of magnetic field in 1979, worldwide researches on this issue have been conducted. More recently, the U.S. Congress instructed the NIEHS (National Institute of Environmental Health Sciences), NIH (National Institute of Health) and DOE (Department of Energy) to direct and manage EMF RAPID (Electric and Magnetic Fields Research and Public Information Dissemination) program aimed at providing scientific evidence to clarify the potential for health risks from exposure to extremely low frequency electric and magnetic fields(ELF-EMF). Although they concluded that the scientific evidence suggesting adverse health risks of ELF-EMF is weak, the exposure to ELF-EMF cannot be recognized as entirely safe. Therefore, the purpose of this article is to describe magnetic field 3-D calculation and to evluate eddy current of human body compare to international guide line recognized one of the basic problems. In open boundary problem, Magnetic field using FEM is not advantageous in the point of the division of area and the proposition of the fictitious boundary. Therefore, we induced the analytic equation of magnetic field calculations so but the finite line segment based on Biot-Savarts law Also, Eddy currents induced due to ELF-EMF magnetic field are computed. To calculate induced currents, impedance method is used in this paper, An example model of human head with resolution of 1.27cm is used. In this paper, We evaluate the magnetic field and eddy current of human head around 765 kV transmission lines compare to international guide line.

경계에서의 음향 임피던스 특성에 대한 연구 고찰 (Brief Note on Acoustic Impedance Characteristics at Flow Boundaries)

  • 서성현
    • 한국추진공학회지
    • /
    • 제21권6호
    • /
    • pp.103-109
    • /
    • 2017
  • 연소화염 열에너지와 결합된 음향에너지 증가는 연소 불안정성을 유발할 수 있다. 연소 안정성 예측을 위해서는 연소실 내부 유동 경계에서 음향특성을 파악해서 궁극적으로 음향에너지의 증가 여부를 파악하는 것이 필요하다. 본 논문에서는 연소기 헤드와 같은 유동 경계 형상에 대한 음향 특성을 연구한 기존의 주요 분석적 결과를 정리하여, Strouhal 수로 표현되는 경계면 음향 임피던스 특성을 알아보았다. 또한 이중 마이크로폰을 활용한 실험적 방법을 통해 경계 음향 임피던스 특성에 대한 이론적/해석적 결과를 검증하기 위한 기법을 조사 정리하였다.

피부색에 따른 병변치료를 위한 광조사펄스모델링에 대한 설계 및 구현 (Design and embodiment about pulse modeling of light investigation for disease treatment by skin color)

  • 김휘영
    • 한국컴퓨터산업학회논문지
    • /
    • 제7권5호
    • /
    • pp.563-572
    • /
    • 2006
  • 피부를 통한 최적의 광투과 치료방식은 국소병변에 직접적으로 광을 조사할 수 있는 장점을 가지나 피부의 가장 바깥 부분인 각질부의 다양한 피부색상으로 인해 광전달 능력에 차이가 있고 다양한 환자에 따라 치료가 부적절 할 수가 있다. 본 연구에서는 피부 임피이던스에 따른 광조사 방식에 따른 일정한 측정을 하기 위해 피부 임피이던스 방식과 피부영역 추출을 통해 색상정보와 차영상을 이용한 방법 즉, 색상정보를 이용한 HIS와 YIQ의 성분이 가장 보편적인데 실험에서는 피부색상에 해당하는 각 색상성분을 탐색한 다음, 색상정보를 이용한 결과로 환자의 피부모델 영역검출에 따라 결과를 영상정보를 통해 개개인의 피부모델을 자동적으로 생성, 측정하여 피부색깔, 에너지, 파장, 폭, 조사시간, 펄스지연 등을 추출하여 원하는 최적의 모델과 특성을 조사하며, 피부 임피이던스에 따른 병변치료 펄스모델링의 기준을 구하였고, 피부부하에 따른 최적의 광조사 펄스모델링 시스템을 설계하여 제작하여, 피부칼라에 따른 적절한 치료펄스 데이터베이스를 구축하였다.

  • PDF

Esophageal Bolus Transit in Newborns with Gastroesophageal Reflux Disease Symptoms: A Multichannel Intraluminal Impedance Study

  • Cresi, Francesco;Liguori, Stefania Alfonsina;Maggiora, Elena;Locatelli, Emanuela;Indrio, Flavia;Bertino, Enrico;Coscia, Alessandra
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제18권4호
    • /
    • pp.238-245
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate bolus transit during esophageal swallow (ES) and gastroesophageal reflux (GER) events and to investigate the relationship between the characteristics of ES and GER events in a population of term and preterm newborns with symptoms of gastroesophageal reflux disease (GERD). Methods: The study population consisted of term and preterm newborns referred to combined multichannel intraluminal impedance (MII) and pH monitoring for GERD symptoms. The frequency and characteristics of ES and GER events were assessed by two independent investigators. Statistical significance was set at p<0.05. Results: Fifty-four newborns (23 preterm) were included in the analyses. Median bolus head advancing time corrected for esophageal length (BHATc) was shorter during mealtime than during the postprandial period (median, interquartile range): 0.20 (0.15-0.29) s/cm vs. 0.47 (0.39-0.64) s/cm, p<0.001. Median bolus presence time (BPT) was prolonged during mealtime: 4.71(3.49-6.27) s vs. 2.66 (1.82-3.73) s, p<0.001. Higher BHATc (p=0.03) and prolonged BPT (p<0.001) were observed in preterm newborns during the postprandial period. A significant positive correlation between BHATc and bolus clearance time was also observed (${\rho}=0.33$, p=0.016). Conclusion: The analysis of ES and GER events at the same time by MII provides useful information to better understand the physiopathology of GERD. In particular, the analysis of BHATc during the postprandial period could help clinicians identify newborns with prolonged esophageal clearance time due to impaired esophageal motility, which could allow for more accurate recommendations regarding further tests and treatment.

반도체/디스플레이 소자용 초음파 건식세정 시뮬레이션 연구 (Simulation of Ultrasonic Dry Cleaning for Semiconductor/display Device Application)

  • 윤의중;이강원;김철호;이석태
    • 한국전기전자재료학회논문지
    • /
    • 제17권12호
    • /
    • pp.1259-1263
    • /
    • 2004
  • In this paper, the optimum design of ultrasonic dry cleaning head was investigated. The transducer instead of mechanical dynamic structure was used to generate ultrasonic wave and the horn-shape amplifier was utilized to solve the energy decaying problem of ultrasonic wave with propagating it through the media. The analyses of ultrasonic wave and a fluid for the selected structure of a cleaning head were carried out using SYSNOISE and ANSYS simulators, respectively. Based on simulator results, the distance between a horn and the substrate of 4 mm and the horn diameter of 10 mm were determined to maximize the energy of ultrasonic waves. The cooling structure was also considered to reduce the heat from the transducer and the horn. The equivalent circuit for the fabricated horn was deduced from HP4194A impedance/gain/phase analyzer and the frequency of an ultrasonic wave of 20.25 kHz was confirmed using the parameters of the equivalent circuit.

인후두 역류 질환: 진단 및 치료 (Laryngopharyngeal Reflux Disease: Diagnosis and Treatment in 2021)

  • 강정욱;은영규
    • 대한후두음성언어의학회지
    • /
    • 제32권2호
    • /
    • pp.56-63
    • /
    • 2021
  • Laryngopharyngeal reflux disease (LPRD) is an inflammatory condition of the upper aerodigestive tract mucosa induced by reflux content from stomach. Some of vocal cord diseases are associated with laryngopharyngeal reflux. Because of the pathophysiological features, proton pump inhibitor shows therapeutic effect on some vocal cord diseases. As like that, the gastric reflux contents can make macroscopic or microscopic morphological changes in the upper aerodigestive tract mucosa. Although the pathophysiology of LPRD is relatively clear, clinical diagnosis is still difficult. The diagnosis of LPRD includes objective tests such as 24-hours multichannel intraluminal impedance-pH metry and subjective tests such as questionnaire method. However, the objective verification of reflux is difficult due to invasiveness of the method, and the questionnaire methods have limitations because many symptoms are not specific for LPRD. Moreover, most methods are not fully standardized until now. Despite these limitations, many researchers are struggling to standardize diagnosis and treatment of LPRD, and there are several new achievements recently. Therefore, the purpose of this article is to review the recent literature on the clinical presentation, diagnosis, and treatment of LPRD, and to systematize our knowledge.

휴대폰 전자파와 인체의 상호 영향 및 뼈 유사 물질 합성 연구 (Electromagnetic Interactions between a Cellular Phone and the Human Body and Synthesis of a Bone-Equivalent Material)

  • 윤용섭;김인광;전중창;박위상
    • 한국전자파학회논문지
    • /
    • 제10권2호
    • /
    • pp.277-290
    • /
    • 1999
  • 유한차분 시간영역 수치해석 기법을 사용하여 휴대폰과 인체 간의 전자파 결합 현상을 시율레이션하였고, 인체 두부의 모형을 제작하기 위한 생체 뼈 유사 물질의 합성에 관한 연구를 수행했다. 휴대폰 모형을 제작 하여 자유 공간에서 안테나 반사계수 및 복사 패턴을 측정하였다. 인체와 안테나 사이의 거리를 매개 변수로 하여 안테나의 입력 임피던스, 반사계수, 복사 패턴, 효율, 그리고 인체 두부의 전력 홉수량을 계산하였다. 인 체 근접 효과에 의하여 안테나 공진 주파수가 약 12 %까지 감소되었으며, 출력이 0.6W일 때, 두부와 안테나 사이의 거리가 30mm이상 떨어져 있을 경우, l-g 평균 최대 SAR가 ANSVIEEE 안전 기준인 1.6 W /kg 이 하로 계산되었다. 뼈 유사 물질의 합성에는 에폭시, 응고제, 그리고 흑연 분말을 기본 물질로 하고, 전도도를 제어하기 위해 소량의 전도성 에폭시를 첨가하였다. 850 MHz에서 비유전율이 18.04, 전도도가 0.347로서 생체 뼈의 특성에 매우 근접하는 시료가 합성되었음을 보였다.

  • PDF

파워흐름해석법의 신뢰성 검증을 위한 원통형 구조물의 진동실험 (Vibration Experiments of the Cylindrical Structure for Verifying the Reliability of Power Flow Finite Element Method)

  • 이호원;홍석윤;박영호;길현권;김창열;전재진;류정수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.290-297
    • /
    • 2002
  • Vibration experiments have been performed to observe the analytic characteristics of power How finite element method(PFFEM) for the reinforced cylindrical structure. For this, the vibration experimental results are compared with the numerical solutions obtained by PFFEM in medium-to-high frequency ranges. Input Power into the experimental structure is measured using the impedance head adhered to the exciter, and that input power is used for the vibration analysis. Using the developed PFFEM program(PFADS), the reinforced cylindrical structure modeled by beam and plate elements is analyzed, and very reliable results for PFFEM are obtained by the comparisons of the experimental results.

  • PDF

Wobbling Mass를 고려한 인체 진동 모텔의 개발 (Development of Human Body Vibration Model Including Wobbling Mass)

  • 김영은;백광현;최준희
    • 한국자동차공학회논문집
    • /
    • 제10권2호
    • /
    • pp.193-200
    • /
    • 2002
  • Simple spring-damper-mass models have been widely used to investigate whole-body vortical biodynamic response characteristics of the seated vehicle driver. Most previous models have not considered the effect of wobbling masses; i.e. heart, lungs, liver, intestine, etc. In this study, 4 -DOF seated driver model including one non-rigid mass representing wobbling visceral mass, 5-DOF model including intestine, and 10-DOF model including five lumbar vertebral masses were proposed. The model parameters were identified by a combinatorial optimization technique. simulated annealing method. The objective function was chosen as the sum of error between model response of seat-to-head transmissibility and driving point mechanical impedance and those of experimental data for subjects seated erect without backrest support. The model response showed a good agreement with the experimental response characteristics. Using a 10-DOF model, calculated resonance frequency of lumbar spine at 4Hz was matched well with experimental results of Panjabi et al.