• 제목/요약/키워드: Impact noise test

검색결과 276건 처리시간 0.025초

골프채 타격음의 음질 평가기법에 관한 연구 (The Study of Sound Quality Metrics for the Golf Club's Impact Sound)

  • 김관주;박진규;박희준
    • 한국소음진동공학회논문집
    • /
    • 제16권5호
    • /
    • pp.537-543
    • /
    • 2006
  • The impact sound of the golf club is one of the major factors to purchase it. Sound quality metrics has been mostly developed for harmonic sounds. Sound quality evaluation techniques for the impact sound have been contrived in this study. Jury test, one of the typical subjective evaluation scheme, is carried out for evaluating the sound quality of 13 different golf drivers, which classification results are assumed to be correct answers. Conventional objective evaluation methods such as Zwicker loudness sensory pleasantness are calculated. Wavelet analysis and instantaneous loudness are applied in order to evaluate the sound quality of transient sounds, which scheme shows better correlation with the results from jury test.

낙하 충격 실험을 통한 자기유변탄성체의 충격 흡수 성능 평가 (The Evaluation of Shock Absorption Performance of Magneto-Rheological Elastomer Through the Drop Impact Test)

  • 정경식;이철희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.92-93
    • /
    • 2013
  • In this study, Shock Absorption performance of Magneto-rheological elastomer(MRE) is identified through the drop impact test. Magneto-rheological materials are divided into two groups by MR fluid in fluid state and MR elastomer in solid state like rubber. The stiffness characteristics of Magneto-rheological material can be changed as magnetic field is applied. The impact loads in MR elastomer were measured under weight of impactor. Experiment results are shown through the experiments to confirm the effect of shock absorption of MR elastomer. Thus, the MR elastomer can be applied to shock absorber used in area that shock occurs.

  • PDF

경량 바닥구조의 바닥충격음 저감량 실험실 측정방법 고찰 (Review of measurement of impact sound improvement for light-weight floor)

  • 장길수;정광용;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.950-955
    • /
    • 2002
  • ISO 140-11 specifies a method for measuring the acoustic properties of floor coverings from the view-point of reducing impact sound transmission. This test method is limited to the specification of procedures for the physical measurement of sound originating from an artificial impact source under laboratory conditions. In this study, ISO 140-11 was reviewed to applicable to domestic floor coverings installed on lightweight floors.

  • PDF

경량바닥구조의 바닥충격음 저감량 실험실 측정방법 고찰 (Review of measurement of impact sound improvement for light-weight floor)

  • Jang, Gil-Soo;Kim, Sun-Woo;Jung, Kwang-Yong
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.392.2-392
    • /
    • 2002
  • ISO 140-11 specifies a method for measuring the acoustic properties of floor coverings from the view-point of reducing impact sound transmission. This test method is limited to the specification of procedures for the Physical measurement of sound originating from an artificial impact source under laboratory conditions. In this study, ISO 140-11 was reviewed to applicable to domestic floor coverings installed on lightweight floors.

  • PDF

소음이 과제수행에 미치는 영향에 관한 연구 (The Study on Affecting Subject Accomplishment by Noise)

  • 김성철;박근상;김관우
    • 대한인간공학회지
    • /
    • 제29권1호
    • /
    • pp.121-128
    • /
    • 2010
  • The purpose of this study is to confirm the impact of noise on subject accomplishment as well as physical/mental load, and evaluates the effects of noise-masking and earplug. 15 college students participate in the test, and the comparison is performed by executing four projects according to conditional categories of noise environments; control condition, noise condition, earplug condition, and noise-masking condition. Noise in the field site of the H manufacturer was used as the noise source, the general job aptitude test which consist of linguistic ability, math ability, perception ability, reasoning ability was used as the task of this project. To estimate physical/mental load evaluation, we used the heart rate R-R interval, Criteria flicker fusion frequency(CFF) and measured NASA-TLX workload for subjective evaluation. As the research outcome, it is shown that there is a meaningful difference for the project task score, dropping rate of CFF, the heart rate, and NASA-TLX subjective evaluation score according to conditions of noise environment. Therefore, the impact of noise on capability of subject accomplishment as well as physical/mental load was confirmed along with the effects of using earplug and noise-masking.

실충격원을 고려한 바닥충격음 저감방안의 평가 (Evaluations on isolation method of floor impact sounds by real impact source)

  • 유승엽;이평직;정영;전진용;류종관
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.366-370
    • /
    • 2006
  • In this study, characteristics of impact force and impact sound of impact source such as bang machine, impact ball, and children's jumping were review. Results of review showed that impact ball has most similar characteristic to real impact sources in terms of objective properties such as impact force and impact sound. The effects of various isolator on floor impact sound were also investigated in apartment building and test facilities building using bang machine an impact ball. From the field measurement, it was found that the difference in reduction sound level between bang machine and impact ball was relatively large and the reduction sound level by impact ball was much larger than bang machine.

  • PDF

공동주택 리모델링 현장의 바닥충격음 저감대책 (Reduction Method for Floor Impact Noise on APT Remodeling)

  • 박철용;홍구표;이중원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.524-525
    • /
    • 2009
  • Heavy-weight impact noise(HN) is the most irritating noise in Korean apartment houses. It has been proclaimed standard floor system of 210mm thick slab with isolation material in the wall type structure. But this regulation is applied only new construction field and is not considered remodeling field. In general, the LN can be reduced by using isolation material but HN is known as relating with stiffness, strength & boundary condition of slab. Therefore it is difficulty in improving the HN on remodeling field. In this study, We conducted the reinforcement of concrete slab using C.F.S.(carbon fiber sheet), steel plate and steel beam after on-dol with isolation material on the remodeling field. As the test results, It appeared using C.F.S was no improved but using steel plate & steel beam were a little improved on HN.

  • PDF

시스템 해석을 이용한 뜬바닥구조에서의 바닥구조 동특성과 뱅머신의 충격력 특성 분석 (An Analysis of Characteristics of Floor Dynamic Properties and Bang-machine Impact Force on Floating Floor Using System Analysis)

  • 문대호;박홍근;황재승;홍건호
    • 한국소음진동공학회논문집
    • /
    • 제24권5호
    • /
    • pp.390-398
    • /
    • 2014
  • Heavy-weight floor impact noise is directly related to the impact source and floor vibration property. Dynamic properties of the standard floating floor that is used in Korea was investigated using accelerance, acceleration energy spectral density(ESD), and structural modal test. In the standard floating floor, natural frequency was decreased by the finishing mortar mass and the damping ratio was increased. Bang-machine force spectrum acting on the concrete slab can be calculated using inverse system analysis. Impact force acting on concrete slab is changed by interaction of finishing mortar and resilient material. The amplitude of the bang-machine force spectrum was amplified in low frequency range(below 100 Hz), and over 100 Hz was decreased. Changed force spectrum influence to the response of structure vibration, so the heavy-weight floor impact noise level was changed.

비공기압 방식 소형 산업용 바퀴의 설계를 위한 수치해석과 진동실험에 관한 연구 (A study on design of non-pneumatic small industrial wheel using FEM and vibration tests)

  • 홍필기;손창우;서태일
    • Design & Manufacturing
    • /
    • 제12권3호
    • /
    • pp.48-54
    • /
    • 2018
  • This paper presents a numerical study for the development of a low-noise low-vibration industrial wheel for non-pneumatic wheel to significantly reduce vibration and noise. For this, design, injection molding and performance testing were performed. Various geometric shapes and materials were taken into account. For numerical analysis, ANSYS, LS-Dyna, and ABAQUS were used to predict the behavior of the wheel under different loadings based on various design changes. Based on this, 4 prototypes were fabricated by changing the design of wheels and molds, and various vibration and noise tests were carried out. A vibration tester was developed and tested to perform the vibration noise test considering durability. A prototype and test of the final wheel was performed. In the case of the vibration test, the vibration levels were 81.16dB and 80.66dB, which were below the target 90dB. Noise levels were 53.20 dB and 52.55 dB below the target 65dB. In the case of the impact resistance test, it was confirmed that there was no change in appearance after impact. The product weight was measured to be 174g compared to the target of 190g.

수음실 잔향시간 변화에 따른 중량 충격음 레벨 특성 - 실험실 환경을 중심으로 - (Floor Impact Sound Pressure Level Characteristics by the Change of Reverberation Time in Mock-up Test Rooms)

  • 정정호;이병권;연준오;전진용
    • 한국소음진동공학회논문집
    • /
    • 제24권4호
    • /
    • pp.339-347
    • /
    • 2014
  • Floor impact sound in high-rise apartment building became one of social problems. A lot of civil complaints on floor impact sound occur continuously and the number of disputes between neighbors in small and aged apartment buildings is increasing. Interests on heavy-weight impact sound pressure level measurement and evaluation method is increased. Previous study reported that heavy-weight impact sound level was changed by the sound field condition of receiving reverberation chamber. In this study, heavy-weight impact sound pressure level change by the receiving sound field condition was measured in standard test facility and mock-up test room. These two experimental conditions were designed to simulate averaged living room of common apartment units. By the change of sound absorption power in receiving room, heavy-weight impact sound pressure level in most of frequency bands were changed in standard test facility and mock-up room. Normalized maximum sound pressure level regulated in ISO 16032 showed wider range of heavy/soft impact sound pressure level. Heavy/soft impact sound pressure level change was became smaller by the application of standardized maximum sound pressure level and ISO/CD 10140-3 Amd 2 method. In the case of standardized maximum sound pressure level, absolute sound pressure level changed. From these results, receiving sound field correction method regulated in ISO/CD 10140-3 Amd 2 is needed for the precision measurement and evaluation of heavy-weight impact sound.