• 제목/요약/키워드: Immediate functional loading

검색결과 19건 처리시간 0.024초

Immediate placement and functional loading of implants on canine with fixed partial denture for a patient having canine protected occlusion: a case report

  • Hong, Jun-Won;Ahn, Seung-Geun;Leem, Dae-Ho;Seo, Jae-Min
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권1호
    • /
    • pp.52-56
    • /
    • 2012
  • Conventional implant protocols required a load-free healing period of three to six months between placement and functional loading of the implants. Many efforts have been made to minimize the duration of treatment time. Several literatures have documented immediate function with provisional or definitive prosthesis within a week of the placement in response to these demands. In addition, immediate implant placement has advantages such as shortened treatment time and preservation of soft tissue architectures. This article presents immediate implant placement into fresh extraction sockets followed by functional immediate loading with provisional prosthesis on canine and premolars for a patient having canine protected occlusion.

완전 무치악에서 즉시 부하시와 표준 부하시 임플란트 생존율에 대한 비교 분석: 후향적 연구 (Comparative analysis of immediate functional loading and conventional loading about implant survival rate in the completely edentulous: Retrospective study)

  • 서현수;박준우;홍순민;이석련
    • 대한치과의사협회지
    • /
    • 제52권12호
    • /
    • pp.771-782
    • /
    • 2014
  • Introduction: This study researched the clinical application of immediate functional loading technique about implant survival rate in the completely edentulous and suggested our protocol about surgical & prosthetic procedure. Materials and methods: 32 consecutive patients participated in this study. A total of 242 implants were inserted. In test group, 144 implants were inserted in 19 patients with immediate functional loading with occlusal contact. In control group, 98 implants were inserted in 13 patients and conventional loading was done after 4~6 months. Result: In the immediately loaded implants group, overall cumulative survival rate was 98.6%.

Histomorphometric analysis of an immediate non-functional loaded implant in dogs

  • Ha, Jeong-Wan;Kim, Su-Gwan;Kim, Hak-Hyun;Moon, Seong-Yong;Lim, Sung-Chul
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권1호
    • /
    • pp.90-94
    • /
    • 2008
  • The purpose of this study was to investigate the effects of immediate non-functional loading by analyzing histomorphology around the implant tissues in dogs. Five eight- to nine-month-old full-grown dogs weighing around 12 kg were used in the study. Group I (control group) comprised those in which delayed loading was applied to the right side of the mandible, and Group II (experimental group) consisted of dogs in which immediate loading was performed on the left side of the mandible. Resorbable blast media (RBM)-treated double-threaded US III implants measuring 3.5 mm in diameter and 11 mm long were used in the study. Each animal received four implants in each group, for a total of 40 implants. Cemented type abutments were used after implantation. An 8-week period was allowed for bone healing and an abutment was placed after exposing the periosteum for loading. An implant sample was obtained from bone blocks taken when the dogs were killed at 16 weeks after loading. A Mann-Whitney U-test was performed to evaluate statistical significance. Student's t-test was used for the histological evaluation. The bone formation ratio in Groups 1 and 2 was 88.23 and 86.41%, respectively. No significant difference in new bone formation was observed in the two groups. As no significant difference was seen in new bone formation between the delayed and immediate loading groups, early loading might be possible after implant placement.

상악전치부임플란트에서의 즉시식립 후 심미수복증례 (Case Report; Esthetic Restorations for Immediate Implantation and Delayed loading on Maxillary Anterior Region)

  • 이희경
    • 대한치과의사협회지
    • /
    • 제55권10호
    • /
    • pp.733-737
    • /
    • 2017
  • Successful osseo-integration of dental implants that Dr. Bronemak reported in 1965 had been ground-breaking research in the restorative dentistry for the missing dentition. Clinical application of dental implants in the restorative dentistry has begun with the role of retention and support for the complete denture, beyond the functional recovery in partially missing area, and succeeds in the cosmetic recovery for anterior missing area. Recently, immediate implantation and loading after the extraction have been preferred by many excellent clinicians especially on maxillary anterior missing area, because they want to prevent from the absorption of residual alveolar bone. But it is hard to decide immediate loading for common clinicians also, because it is difficult for them to convict proper osseo-integration. In this article, immediate implantation and delayed loading case on maxillay anterior region have been introduced and predictable prosthetic procedure for the esthetic result has suggested.

  • PDF

Results of immediate loading for implant restoration in partially edentulous patients: a 6-month preliminary prospective study using SinusQuickTM EB implant system

  • Kim, Jong-Hwa;Kim, Young-Kyun;Yi, Yang-Jin;Yun, Pil-Young;Lee, Hyo-Jung;Kim, Myung-Jin;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권3호
    • /
    • pp.136-139
    • /
    • 2009
  • STATEMENT OF PROBLEM. Many dental clinicians are concerned about immediate loading of inserted implants. However, there have been few clinical studies surveying the success rates of immediate loading, based on Korean implant systems. PURPOSE. The aim of this study was to evaluate the outcome of immediate functional loading of the implant ($SinusQuick^{TM}$EB, Neobiotech Co., Seoul, Korea) in partially edentulous maxilla or mandible. MATERIAL AND METHODS. Total 15 implants were placed. Within 2 weeks after implant insertion, provisional implant-supported fixed partial dentures were delivered to the patients. Quantitatively, marginal bone loss was measured at the time of immediate loading, after 3-months of continued loading and at the last follow-up. The mean follow-up period was 4.8 months. RESULTS. Mean marginal bone loss from implant surgery to early loading, 3-months follow-up and last follow-up was $0.03\pm0.07$ mm, $0.16\pm0.17$ mm and $0.29\pm0.19$ mm. No implant failed up to 6 months after insertion, resulting in a 100% survival rate. CONCLUSION. Immediate loading exhibited high success rate in partial edentulism for up to 6 months. Well-controlled long term clinical studies with large sample size are necessary to confirm this finding.

A resonance frequency analysis of sandblasted and acid-etched implants with different diameters: a prospective clinical study during the initial healing period

  • Kim, Hyun-Joo;Kim, Yeun-Kang;Joo, Ji-Young;Lee, Ju-Youn
    • Journal of Periodontal and Implant Science
    • /
    • 제47권2호
    • /
    • pp.106-115
    • /
    • 2017
  • Purpose: The possibility of immediate or early loading has become popular in implant dentistry. A prerequisite for the immediate or early loading of an implant prosthesis is the achievement of initial stability in the implant. Moreover, in response to clinicians' interest in verifying clinical stability to determine the optimal time point for functional loading, a non-invasive method to assess implant stability has been developed on the basis of resonance frequency analysis (RFA). The primary objective of this study was to monitor the stability of sandblasted, large-grit, and acid-etched (SLA) implants with different diameters during the early phases of healing by RFA. The secondary objective was to evaluate how the initial stability of implants varied depending on different surface modifications and other contributing factors. Methods: Thirty-five implants (25 SLA implants and 10 resorbable blasting media [RBM] implants) placed in 20 subjects were included. To measure implant stability, RFA was performed at baseline and at 1, 2, 3, 4, 6, and 10 weeks after surgery. Results: The longitudinal changes in the implant stability quotient (ISQ) values were similar for the SLA implants with different diameters and for the RBM implants. During the initial healing period, the ISQ decreased after installation and reached its lowest values at 1 week and 2 weeks, respectively. The mean ISQ values in the SLA implants were significantly higher in ${\varnothing}5.0mm$ implants than in ${\varnothing}4.0mm$ implants. Men showed a higher ISQ than women. Mandibular sites showed a higher ISQ than maxillary sites. Conclusions: All implants used in this study are suitable for immediate or early loading under appropriate indications. A wider diameter and SLA surface treatment of implants could improve the stability, if the implant is fixed with at least 30 Ncm of insertion torque.

Clinical application of a new systematic implant planning concept: A Clinical Report

  • Jeong, Seung-Mi;Chung, Chae-Heon;Engelke, Wilfried
    • 대한치과보철학회지
    • /
    • 제38권6호
    • /
    • pp.814-820
    • /
    • 2000
  • Statement of Problem. Commonly used classification systems do not inform for dentists the dimension of the available bone at a potential implant site although regarding a variety of morphologic and pathophysiologic aspects using schematic graphs. However, for the implantologist the availability of bone substance is most important independent whether it concerns the jaw basis or the alveolus. Purpose of Study. The present article refers to a new evaluation form, to analyze the available bone with regard to optional immediate loading site by site. According to a new systematic implant planning concept will be presented in two case reports. Results. The feasibility of the classification for planning and documentation of immediately loaded implants is presented in two case reports. Conclusion. The factor of bone support for immediate functional stability is important in dental implantology. The new systematic implant planning helps to systematically estimate the dimension (ASCIi classification) of the alveolus site by site to evaluate the possibility of immediate loading. The Gottingen classification thus aids to determine the degree of stability that can be expected for the planned solution.

  • PDF

발치 후 즉시 임플란트 식립시 이식된 hBMP-I의 조직학적 고찰 (THE HISTOLOGIC STUDY OF THE GRAFTED hBMP-I FOR IMMEDIATE IMPLANT FIXATION)

  • 이은영;김경원;최희원;엄인웅;정호용
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권4호
    • /
    • pp.316-322
    • /
    • 2004
  • A low molecular weight component named bone morphogenetic protein(BMP) chemically isolated from the organic matrix of bone, induce postfetal connective tissue cells surrounding small blood vessels to differentiate into cartilage and bone. The end product of BMP is a spherical ossicle of lamella bone filled with red bone marrow for the functional loading. This is a important point that the graft material is embedded the defect site during the implant surgery. Because present knowledge of the relationship between BMP and bone regeneration arises mainly from studies of induced bone formation in heterotopic sites, it would be helpful to determine whether BMP plays any part in the process of bone healing. The BMPs have been shown to play crucial roles in normal skeletal development as well as bone healing and are able to activate transcription of genes involved in cellular migration, proliferation, and differentiation. The delivery of BMP on matrices has been efficacious in the treatment of defect bone in implant surgery. The purpose of the histologic study was to evaluate the effect of DLB(demineralized lyophilized bone) coated with purified human BMP(hBMP-I) in immediate implant surgery with bony defect to obtain the functional structure of implant asap. The ability of a graft of hBMP-I to accelerate bony defect repair provides a rationale for its use in immediate implant surgery that have large bone defect in edentulous area.