Histomorphometric analysis of an immediate non-functional loaded implant in dogs |
Ha, Jeong-Wan
(Department of Oral & Maxillofacial Surgery, College of Dentistry, Chosun University)
Kim, Su-Gwan (Department of Oral & Maxillofacial Surgery, College of Dentistry, Chosun University) Kim, Hak-Hyun (Department of Oral & Maxillofacial Surgery, College of Dentistry, Chosun University) Moon, Seong-Yong (Department of Oral & Maxillofacial Surgery, College of Dentistry, Chosun University) Lim, Sung-Chul (Department of Pathology, College of Medicine, Chosun University) |
1 | Albrektsson T, Sennerby L: State of the art in oral implants. J Clin Periodontol 1991;18:474-481 DOI |
2 | Lum LB, Beirne OR, Curtis DA: Histologic evaluation of hydroxylapatite-coated versus uncoated titanium blade implants in delayed and immediately loaded applications. Int J Oral Maxillofac Implants 1991;6:456-462 |
3 | Brunski JB: Avoid pitfalls of overloading and micromotion of intraosseous implants. Dent Implantol Update 1993;4:77-81 |
4 | Akagawa Y, Ichikawa Y, Nikai H, Tsuru H: Interface histology of unloaded and early loaded partially stabilized zirconia endosseous implant in initial bone healing. J Prosthet Dent 1993;69:599-604 DOI ScienceOn |
5 | Roberts WE, Garetto LP, DeCastro RA: Remodeling of devitalized bone threathens periosteal margin integrity of endosseous titanium implants with threaded or smooth surface: Indications for provisional loading and axially directed occlusion. J Indiana Dent Assoc 1989;68:19-24 |
6 | Ledermann PD, Schenk Rk, Buser D: Long-lasting osseointegration of immediately loaded, bar-connected TPS screws after 12 years of function: a histologic case report of a 95-year-old patient. Int J Periodontics Restorative Dent 1998;18:552-563 |
7 | Kawahara H, Kawahara D, Hayakawa M, Tamai Y, Kuremoto T, Matsuda S: Osseointegration under immediate loading: biomechanical stress-strain and bone formationresorption. Implant Dent 2003;12:61-68 DOI |
8 | Romanos GE, Nentwig GH: Single molar replacement with a progressive thread design implant system: a retrospective clinical report. Int J Oral Maxillofac Implants 2000;15:831-836 |
9 | Kim SG: Immediate post-extraction implant and immediate loading implant. Seoul, Daehan Publishing Co, 2005, p 139 |
10 | Corso M, Sirota C, Fiorellini J, Rasool F, Szmukler-Moncler S, Weber HP: Clinical and radiographic evaluation of early loaded free-standing dental implants with various coatings in beagle dogs. J Prosthet Dent 1999;82:428-435 DOI ScienceOn |
11 | Froum S, Emtiaz S, Bloom MJ, Scolnick J, Tarnow DP: The use of transitional implants for immediate fixed temporary prostheses in cases of implant restorations. Pract Periodontics Aesthet Dent 1998;10:737-746 |
12 | Romanos GE, Testori T, Degidi M, Piattelli A: Histologic and histomorphometric findings from retrieved, immediately occlusally loaded implants in humans. J Periodontol 2005;76:1823-1832 DOI ScienceOn |
13 | Albrektsson T, Zarb G, Worthington P, Eriksson AR: The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants 1986;1:11-25 |
14 | Sagara M, Akagawa Y, Nikai H, Tsuru H: The effects of early occlusal loading on one-stage titanium alloy implants in beagle dogs: a pilot study. J Prosthet Dent 1993;69:281-288 DOI ScienceOn |
15 | Tarnow DP, Emtiaz S, Classi A: Immediate loading of threaded implants at stage 1 surgery in edentulous arches: Ten consecutive case reports with 1-to 5-year data. Int J Oral Maxillofac Implants 1997;12:319-324 |
16 | Frost HM: The biology of fracture healing. An overview for clinicians. Part I. Clin Orthop Relat Res 1989;248:283-293 |
17 | Zubery Y, Bichacho N, Moses O, Tal H: Immediate loading of modular transitional implants: a histologic and histomorphometric study in dogs. Int J Periodont Restorative Dent 1999;19:343-353 |