• 제목/요약/키워드: Imaging phantom

검색결과 551건 처리시간 0.021초

방사성의약품 검사 시 진단(CT)영상에 미치는 영향 (The Effects of Diagnostic Radiology Image on Radiopharmaceutical Testing)

  • 이은혜;이예슬;김가중;최준구
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.113-117
    • /
    • 2010
  • This research attempts to qualitatively evaluate the intensity change by radiopharmaceuticals and obtain computed tomography using phantom injected with various nuclide. Cylindrical phantom is used for comparing and analysing the effect on diagnosis image during radiopharmaceuticals inspection. Inside of the phantom, water is injected and computed tomography image is scanned. During nuclear medicine invitro, frequently used radiopharmaceuticals, $^{99m}TcO_4$ 20 mCi and $^{18}F$ 14 mCi, is diluted in the water phantom and scanned in the same method. Traverse image obtained by CT scan is divided into six traverse image in the same slice of each scanned image. CT-number(HU) value of 10 measuring point is measured in 2 cm interval based on the center of the phantom. Measured HU value, based on the water phantom, is compared with the image after injecting $^{99m}TcO_4$ and $^{18}F$. Average scale of water is 2.8~1.6 HU, $^{99m}TcO_4$ is 3.0~1.6 HU and $^{18}F$ is 1.2~0 HU. Average of water is $2.3{\pm}0.17$ HU, $^{99m}TcO_4$ is $2.2{\pm}0.85$ HU and F-18 is $0.7{\pm}0.95$ HU. Based on water, reduced value of about 0.1 HU and about 0.5 HU is acquired from $^{99m}TcO_4$ and F-18. Radionuclide used in nuclear medicine inspection utilizes 100~200 KeV energy and obtains image through scintillation camera and PET-CT utilizes 511 KeV positron annihilation energy to obtain image. What we learned from this research is that gamma rays from these energies used in CT scan for diagnosis purpose or radioactive therapy plan can change the intensity of the image. The nuclear medicine inspection for reducing the effect of emitted gamma ray diagnosis image should be obtained after a period of time considering half-life which would be reduced distortion or changed in image.

  • PDF

Non-Invasive in vivo Loss Tangent Imaging: Thermal Sensitivity Estimation at the Larmor Frequency

  • Choi, Narae;Kim, Min-Oh;Shin, Jaewook;Lee, Joonsung;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권1호
    • /
    • pp.36-43
    • /
    • 2016
  • Visualization of the tissue loss tangent property can provide distinct contrast and offer new information related to tissue electrical properties. A method for non-invasive imaging of the electrical loss tangent of tissue using magnetic resonance imaging (MRI) was demonstrated, and the effect of loss tangent was observed through simulations assuming a hyperthermia procedure. For measurement of tissue loss tangent, radiofrequency field maps ($B_1{^+}$ complex map) were acquired using a double-angle actual flip angle imaging MRI sequence. The conductivity and permittivity were estimated from the complex valued $B_1{^+}$ map using Helmholtz equations. Phantom and ex-vivo experiments were then performed. Electromagnetic simulations of hyperthermia were carried out for observation of temperature elevation with respect to loss tangent. Non-invasive imaging of tissue loss tangent via complex valued $B_1{^+}$ mapping using MRI was successfully conducted. Simulation results indicated that loss tangent is a dominant factor in temperature elevation in the high frequency range during hyperthermia. Knowledge of the tissue loss tangent value can be a useful marker for thermotherapy applications.

Development of Dual Beam High Speed Doppler OFDI

  • Kim, SunHee;Park, TaeJin;Oh, Wang-Yuhl
    • 비파괴검사학회지
    • /
    • 제33권3호
    • /
    • pp.283-288
    • /
    • 2013
  • This paper describes development of a high speed Doppler OFDI system for non-invasive vascular imaging. Doppler OFDI (optical frequency domain imaging) is one of the phase-resolved second generation OCT (optical coherence tomography) techniques for high resolution imaging of moving elements in biological tissues. To achieve a phase-resolved imaging, two temporally separated measurements are required. In a conventional Doppler OCT, a pair of massively oversampled successive A-lines is used to minimize de-correlation noise at the expense of significant imaging speed reduction. To minimize a de-correlation noise between targeted two measurements without suffering from significant imaging speed reduction, several methods have been developed such as an optimized scanning pattern and polarization multiplexed dual beam scanning. This research represent novel imaging technique using frequency multiplexed dual beam illumination to measure exactly same position with aimed time interval. Developed system has been verified using a tissue phantom and mouse vessel imaging.

초음파 의료영상에서 컴파운딩 기법을 이용한 초음파의 평균 음속도의 측정과 음속도 영상의 구현 (Measurement of the Average Speed of Ultrasound and Implementation of Its Imaging Using Compounding Technique in Medical Ultrasound Imaging)

  • 정목근;권성재;최민주
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권3호
    • /
    • pp.233-240
    • /
    • 2009
  • Using a spatial compound imaging technique in a medical ultrasound imaging system, the average speed of sound in a medium of interest is measured, and imaging of its distribution is implemented. When the brightness reaches the highest level in an ultrasonic image obtained as the speed of sound used in focusing is varied, it turns out that the focusing has been accomplished satisfactorily and that the speed of sound which has been adopted becomes the sought-after average speed of sound. Because spatial compound imaging provides many different views of the same object, the adverse effect of erroneous speed-of-sound estimation tends to be more severe in compound imaging than in plain B-mode imaging. Thus, in compound imaging, the average speed of sound even in the case of speckled images can be accurately estimated by observing the brightness change due to different speeds of sound employed. Using this new method that offers spatial diversity, we can construct an image of the speed of sound distribution in a phantom embedded with a 10-mm diameter plastic cylinder whose speed of sound is different from that of the background. The speed of sound in the cylinder is found to be different from that of the surrounding medium.

Super-spatial resolution method combined with the maximum-likelihood expectation maximization (MLEM) algorithm for alpha imaging detector

  • Kim, Guna;Lim, Ilhan;Song, Kanghyon;Kim, Jong-Guk
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.2204-2212
    • /
    • 2022
  • Recently, the demand for alpha imaging detectors for quantifying the distributions of alpha particles has increased in various fields. This study aims to reconstruct a high-resolution image from an alpha imaging detector by applying a super-spatial resolution method combined with the maximum-likelihood expectation maximization (MLEM) algorithm. To perform the super-spatial resolution method, several images are acquired while slightly moving the detector to predefined positions. Then, a forward model for imaging is established by the system matrix containing the mechanical shifts, subsampling, and measured point-spread function of the imaging system. Using the measured images and system matrix, the MLEM algorithm is implemented, which converges towards a high-resolution image. We evaluated the performance of the proposed method through the Monte Carlo simulations and phantom experiments. The results showed that the super-spatial resolution method was successfully applied to the alpha imaging detector. The spatial resolution of the resultant image was improved by approximately 12% using four images. Overall, the study's outcomes demonstrate the feasibility of the super-spatial resolution method for the alpha imaging detector. Possible applications of the proposed method include high-resolution imaging for alpha particles of in vitro sliced tissue and pre-clinical biologic assessments for targeted alpha therapy.

A-Se 기반 디지털 X-선 영상장치의 Contrast-detail 특성 평가 (Evaluation of Contrast-detail Characteristics of an A-Se Based Digital X-ray Imaging System)

  • 현혜경;박소현;김근영;조희문;조효성
    • 한국방사선학회논문지
    • /
    • 제1권1호
    • /
    • pp.11-16
    • /
    • 2007
  • 본 연구에서는 a-Se 기반 디지털 X-선 영상장치의 저대조도 특성을 평가하기 위하여 contrast-detail 곡선 해석을 수행하였다. 본 실험에 사용된 X-선 영상장치는 픽셀크기가 $139mm{\times}139mm$이고 유효면적이 $46.7cm{\times}46.7cm$인 a-Si TFT 기판 위에 500mm 두께의 광전도체가 코팅된 구조를 갖고 있다. Contrast-detail 곡선을 측정하기 위하여 우선 주어진 촬영조건(즉, 40, 50, 60, 70, 80 kVp, and 16 mA.s)에서 상용 팬톰인 CDRAD 2.0을 사용하여 X-선 영상을 획득한 후, 그 영상으로부터 IQFinv 인자를 사용하여 그 특성을 최종 평가하였다. 평가된 IQFinv 값은 주어진 광 플루언스(즉, $1.8{\times}105$, $5.9{\times}105$, $11.3{\times}105$, $19.4{\times}105$, and $29.4{\times}105$ photons/$mm^2$)에서 각각 24.4, 35.3, 39.2, 41.5, 43.4으로 광 플루언스가 증가할수록 점진적으로 증가하였으며 이는 광 플루언스가 증가할수록 영상의 가독성이 향상됨을 나타낸다.

  • PDF

초고주파 가열치료를 위한 MR 호환 동축 슬롯 안테나의 개발 (Development of MR Compatible Coaxial-slot Antenna for Microwave Hyperthermia)

  • 김태형;천송이;한용희;김동혁;문치웅
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권4호
    • /
    • pp.333-340
    • /
    • 2009
  • MR compatible coaxial-slot antenna for microwave hyperthermia was developed while its structure and size of each part were determined by computer simulation using finite element method(FEM). Its local heating performance was evaluated using tissue-mimic phantom and swine muscles. 2% agarose gel mixed with 6mM/$\ell$ $MnCl_2$ as a biological tissue-mimic phantom was heated by the proposed antenna driven by a 2.45GHz microwave generator. The temperature changes of the phantom were monitored using multi-channel digital thermometer at the distance of 0mm, 5mm, 10mm and 20mm from the tip center of the antenna. Also muscle tissue of swine was heated for 2 and 5minutes with 50W and 30W of microwave generator powers, respectively, to evaluate the local heating performance of the antenna. MRI compatibility was also verified by acquiring MR images and MR temperature map. MR signals were acquired from the agarose gel phantom using $T2^*$ GRE sequence with 1.5T clinical MRI scanner(Signa Echospeed, GE, Milwaukee, WI, U.S.A.) at Pusan Paik Hospital and were transferred to PC in order to reconstruct MR images and temperature map using proton resonance frequency(PRF) method and laboratory-developed phase unwrapping algorithm. Authors found that it has no severe distortion due to the antenna inserted into the phantom. Finally, we can conclude that the suggested coaxial-slot antenna has an excellent local heating performance for both of tissue-mimic phantom and swine muscle, and it is compatible to 1.5T MRI scanner.

뇌팬톰을 이용한 삼차원 다중영상정합의 정확성 평가 (Accuracy Evaluation of Three-Dimensional Multimodal Image Registration Using a Brain Phantom)

  • 진호상;송주영;주라형;정수교;최보영;이형구;서태석
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권1호
    • /
    • pp.33-41
    • /
    • 2004
  • 다양한 의학 영상장비로부터 획득된 영상들간의 정합의 정확성은 방사선치료계획에서 매우 중요한 쟁점 중의 하나이다. 본 연구에서는 수제작된 뇌팬톰(brain phantom)을 이용한 영상정합의 정확성 평가방법을 연구하였다. 다중영상정합을 위해 CT-MR, CT-SPECT간의 Chamfer 정합(Chamfer matching)법을 적용하였다 영상정합의 정회성은 팬톰 내에 삽입된 표적(target)들의 중심정의 비교를 통하여 평가되었다. CT-MR, CT-SPECT간의 삼차원 제곱근평균제곱(root-mean-square) 이동편차는 각각 2.1$\pm$0.8 mm와 2.8$\pm$1.4 mm이었다. 회전편차는 세 직교좌표축에서 2$^{\circ}$이내였다. 이 오차들은 기존의 팬톰연구와 비교하여 합리적인 오차 허용범위 내에 들었다. 중첩한 CT-MR, CT-SPECT영상의 육안검증 또한 좋은 정합 결과를 보였다.

초음파 의료영상에서 ATS 535H 팬텀을 이용한 해상력 특성 평가 (Evaluation of the Resolution Characteristics by Using ATS 535H Phantom for Ultrasound Medical Imaging)

  • 민정환;정회원;강혜경
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권1호
    • /
    • pp.15-21
    • /
    • 2023
  • This study was purpose to assessment of the resolution characteristics by using ATS 535H Basic quality assurance (QA) phantom for ultrasound. The ultrasound equipment was used Logiq P6 (Ultrasound, GE Healthcare System, Chicago, IL, USA). And the ultrasound transducer were used Convex 4C (4~5.5 MHz), Linear 11L (10~13 MHz), Sector 3SP (3~5.5 MHz) probe. As for the noise power spectrum (NPS) comparison results by using ATS 535H Basic QA ultrasound phantom and Convex 4C, Linear 11L, Sector 3SP probe. The NPS value of the Convex 4C probe image was 0.0049, Linear 11L probe image was 0.0049, Sector 3SP probe image was 0.1422 when the frequency is 1.0 mm-1. The modulation transfer function (MTF) comparison results by using ATS 535H Basic QA ultrasound phantom and Linear 11L probe the MTF value of the 3 cm focus image was 0.7511 and 4 cm focus image was 0.9001 when the frequency is 1.0 mm-1. This study was presented characteristics of spatial resolution a quantitative evaluation methods by using ultrasound medical images for QA of ultrasound medical QA phantom. The quality control (QC) for equipment maintenance can be efficiently used in the clinic due to the quantitative evaluation of the NPS and MTF as the standard methods. It is meaningful in that it is applied mutatis mutandis and presented the results of physical resolution characteristics of the ultrasound medical image.

혈관협착팬텀의 제작 및 파워도플러의 영상 평가 (Manufacture of Flow Phantom with Stenosis and Imaging Evaluation of Power Doppler)

  • 박희영;배종림;김정구
    • 한국음향학회지
    • /
    • 제28권8호
    • /
    • pp.732-739
    • /
    • 2009
  • 혈관협착의 혈류 정보와 초음파 진단장비의 품질보증을 위한 혈관협착 팬텀을 자동 주입기를 이용하여 제작하였다. 혈관협착의 진단에 효율성이 높은 파워 도플러를 이용하여 제작된 혈관 협착 팬텀의 유용성을 조사하고, 초음파 영상 파라메타에 따른 혈관협착의 정도를 확인하였다. 혈관 협착 팬텀은 직경이 각각 8mm와 2.4mm인 실리콘 튜브로 혈관협착이 70%가 되도록 제작하였으며, 인체 조직과 유사한 음향 특성을 가지고 있는 젤라틴을 이용하여 실리콘 튜브를 감싸 주었다. 평면형 탐촉자를 이용하여 측정하였을 때 정상 혈관의 직경은 대체적으로 감소되어 측정 되었으며, 협착 혈관의 직경은 증가되어 측정되었다. 이득이 60% 이상, PRF가 3000Hz 이상, 필터가 max와 같은 급격한 변화를 제외하고는 각각의 파라메타에 크게 영향을 받지 않았으며, 각도에는 영향을 받지 않는 것으로 나타났다. 또한 곡면형 탐촉자를 이용할 경우 이득, PRF, 필터, 각도등에 영향을 받는 것으로 나타났다. 본 연구에서 제작된 자동주입기를 이용한 혈관 협착 팬텀은 혈관 협착 진단의 품질보증에 유용하게 이용될 수 있을 것으로 기대된다.