Manufacture of Flow Phantom with Stenosis and Imaging Evaluation of Power Doppler  

Park, Hee-Young (한서대학교 방사선학과)
Bae, Jong-Rim (대구대학교 물리학과)
Kim, Jeong-Koo (한서대학교 방사선학과)
Abstract
Flow phantom with stenosis was manufactured using an auto-injector to obtain angiostenotic flow information and quality assurance (QA) for ultrasound diagnostic instrumentation. Effectiveness of manufactured flow phantom with stenosis was investigated with power Doppler that was known to have diagnostic efficiency for angiostenosis. The flow phantom with stenosis was manufactured to 70% stenosis with 8 mm and 2.4 mm silicon tube, and silicone tube was covered with gelatin that has acoustic characteristics similar to soft tissue. When the linear transducer was used for measurement, the estimated diameter of normal vessel was measured lower than that of normal value, and the estimated diameter of stenosed vessel was measured higher than that of normal value. The measured parameters were not affected except for the radical conditions such as gain of 60%, PRF of 3000 Hz, use of maximal filter or angle. In addition, when the convex transducer was used for measurement, measurement parameters were affected by gain, PRF, filter, and angle. Therefore it is expected that flow phantom with stenosis manufactured with an auto-injector will be utilized effectively for QA of angiostenotic diagnosis.
Keywords
Angiostenosis; Phantom; Power Doppler; Auto Injector;
Citations & Related Records
연도 인용수 순위
  • Reference
1 James A. Zagzebski Essentials of ultrasound physics Mosby, Missouri, pp. 116-117, 2000
2 von Krger M.A., Evans D.H., "Doppler ultrasound tracking instrument for monitoring blood flow velocity", Ultrasound in Medicine Biology, vol. 28, no. 11, pp. 1499-1508, 2002   DOI   ScienceOn
3 Golli M., Kriaa S. Said M. et al., "Intrahepatic spontaneous podosystemic venous shunt: Value of color and power Doppler sonography", J. of Clinical Utrasound, vol. 28, no. 1, pp. 47-50, 2000   DOI   ScienceOn
4 Cameron J. Ritchie, Warren S. Edwards, Laurence A. Mack, et al., "Three -dimensional ultrasonic angiogaphy using power doppler", Ultrasound in medicine & Biology, vol. 22, no. 3, pp. 277-288, 1996   DOI   ScienceOn
5 Cameron J. Ritchie, Warren S. Edwards, Laurence A. Mack, et al., “Three -Dimensional Ultrasonic Angiogaphy Using Power Doppler”, Ultrasound in medicine Biology, vol. 22, no. 3, pp. 277-286, 1996   DOI   ScienceOn
6 김현진, "간종양에 대한 색 Doppler 초음파검사와 출력 Doppler 초음파검사의 비교 연구", 이화여자대학교 대학원 석사학위논문, 1997
7 권병덕, 권 양, 임승철 외, "Doppler Ultrasound를 이용한 뇌기저 동맥의 혈류 속도 측정", 대한신경외과학회지, 18권, 3호, 379-388쪽, 1989
8 Guo z. Moreau M, Ricky DW, et al., "Quantitative investigation of in vitro flow using three-dimensional color Doppler ultrasound", Ultrasound Med Biol. vol. 21, no. 6, pp. 807-816, 1995   DOI   ScienceOn
9 Macsweeney JE, Cosgrove DO, Areson J., "Colour Doppler Energy(power) mode ultrasound", Clin. Radiol., vol. 51, no. 6, pp. 387-390, 1996   DOI   ScienceOn
10 Gordon l.L., "Effect of stenosis on transit-time ultrasound measurements of blood flow", Ultrasound in Medicine & Biology, vol. 21, no. 5, pp. 622-633, 1995
11 Kumar V. Ramnarine, Dariush K. Nassiri, Peter R. Hoskins And Jaap Lubbers, “Validation Of a New Blood-Mimicking Fluid For Use In Doppler Flow Test Objects”, Ultrasound in Medicine & Biology, vol. 24, no. 3, pp. 451-459, 1998   DOI   ScienceOn
12 D. W. Rickey, P. A. Picot, D. A. Christopher and A. Fenster, “A Wall-Less Vessel Phantom For Doppler Ultrasound Studies”, Ultrasound in medicine & Biology, vol. 21, no. 9, pp. 1163-1176, 1995   DOI   ScienceOn
13 Barth R.A., Shortliffe L.D., “Normal pediatric testis : comparison of power Doppler and color Doppler US in the detection of blood flow”, Radiology, vol. 204, no. 2, pp. 380-393, 1997
14 Ander Nilsson, Per-Ake Olofsson, Lennart Carlstedt, et al., "Color Doppler Energy : computer Analysis of color to Assess angle Dependency and Detection of Volume Flow Difference", J. Utrasound Med., vol. 16, no. 4, pp. 275-279, 1997   DOI
15 한병인, 사진과 그림으로 배우는 초음파 뇌혈류 검사, 푸른솔, 2004
16 Meyerrovvitz CB, Fleischer AC, Pickens DR. et al., "Quantification of tumor vascularity arid flow with amplitude color Doppler sonography in experimental model: preliminary results", J. Ultrasound Med., vol. 15, no. 12, pp. 827-833, 1996   DOI
17 Rubin JM, Bude RO, Corson PL, et al,, "Power Doppler US : a potentially useful alternative to mean frequency-based color Doppler US", Radiology, vol. 190, no 3, pp. 853-856, 1994   DOI
18 최춘곤, "Flow Signal in 3D TOF MRA : Flow Phantom Study", 서울대학교 대학원 석사학위논문, 1995