• Title/Summary/Keyword: Imaging method

Search Result 3,062, Processing Time 0.037 seconds

A Randomized Comparative Study of Blind versus Ultrasound Guided Glenohumeral Joint Injection of Corticosteroids for Treatment of Shoulder Stiffness

  • Lee, Hyo-Jin;Ok, Ji-Hoon;Park, In;Bae, Sung-Ho;Kim, Sung-Eun;Shin, Dong-Jin;Kim, Yang-Soo
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.3
    • /
    • pp.120-127
    • /
    • 2015
  • Background: We prospectively compared the response to blind and ultrasound-guided glenohumeral injection of corticosteroids for treatment of shoulder stiffness. Methods: A total of 77 patients with shoulder stiffness between April 2008 and March 2012 were recruited. Patients were randomized to receive either a blind (group 1, n=39) or ultrasound-guided (group 2, n=38) glenohumeral injection of 40 mg triamcinolone. The clinical outcomes and shoulder range of motion (ROM) before injection, at 3, 6, and 12 months after injection and at the last follow-up were assessed. The same rehabilitation program was applied in both groups during the follow-up period. Results: There was no significant difference in demographic data on age, sex, ROM, and symptom duration before injection between groups (p>0.05). There were no significant differences in ROM including forward flexion, external rotation at the side, external rotation at $90^{\circ}$ abduction, and internal rotation, visual analogue scale for pain and functional outcomes including American Shoulder and Elbow Surgeons score, Simple Shoulder test between the two groups at any time point (p>0.05). Conclusions: Based on the current data, the result of ultrasound-guided glenohumeral injection was not superior to that of blind injection in the treatment of shoulder stiffness. We suggest that ultrasound-guided glenohumeral injection could be performed according to the patient's compliance and the surgeon's preference. Once familiar with the non-imaging-guided glenohumeral injection, it is an efficient and reliable method for the experienced surgeon. Ultrasound could be performed according to the surgeon's preference.

Application of Laser-based Ultrasonic Technique for Evaluation of Corrosion and Defects in Pipeline (배관부 부식 및 결함 평가를 위한 레이저 유도 초음파 적용 기술)

  • Choi, Sang-Woo;Lee, Joon-Hyun;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.2
    • /
    • pp.95-102
    • /
    • 2005
  • There are many tube and pipeline in nuclear power plant under high temperature and high pressure. Erosion and corrosion defects were expected on these tube and pipe-line by environmental and mechanical factors. These erosion and corrosion defects ran be evaluated by ultrasonic technique. In these study, Scanning Laser Source(SLS) technique was applied to detect defect and construct image. This technique also makes detection possible on rough and curved surfaces such as tube and pipe-line by scanning. Conventional ultrasonic scanning technique requires immersion of specimen or water jet for transferring ultrasonic wave between transducer and specimen. However, this SLS technique does not need contacting and couplant to generate surface wave and to get flaw images. Therefore, this SLS technique has several advantages, for complicated production inspection, non-contact, remote from specimen, and high resolution. In this study, SLS images were obtained with various conditions of generation laser ultrasound and receiving in order to enhance detectability of flaws on the tube. Stress corrosion cracks were produced on tube and images of stress corrosion cracks were constructed by using SLS technique.

Usefulness of Three-Dimensional CT Image in Meningioma Using Contrast Method (조영법을 이용한 뇌수막종에서 3차원 CT영상의 유용성)

  • Lee, Jun-Haeng;Baek, Sung-Eun;Lee, Sang-Bock;Kim, Yong-Wan
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.1
    • /
    • pp.17-21
    • /
    • 2008
  • Because of the reason that the meningioma is enhanced lately, we started the study to maximally enhance the meningioma. we were to know the relation between meningioma and vessels in the skull and compared 3D CT angiography with the conventional angiography. we got the data from 6 patients performed by both 3D CT angiography and there were 5 cases in sphenoidal ridge and 1 case parasagittal sinus. Injecting the contrast media at 3 ml/sec, 120 ml and then the CT number reached 100, we started the study using the medical system Program(smart prep). The scan parameters were HS-Mode(1.25 mm / 7.5 mm) right after being injected all and reconstructed with 0.5 mm interval. We compared the study with the conventional angiography after reconstructing the images required by using 3D-Med software Program(Rapidia). Seeing the consequences, the maximum enhancing time in the menigioma is about 120~180 seconds after injecting the contrast media and we distinguished the relation between vessels and tumors at the time and 1 case showed us the aneurysm with a tumor clearly at the time too. It was very helpful to the operation that the 3D images required by injecting the contrast media to the patients with meningioma distingushed between tumors and vessels dimensionally.

  • PDF

A Preliminary Study on Measuring Void Fraction in a Fuel Rod Assembly by using an X-ray Imaging System (X선 영상 장치를 이용한 핵연료 집합체 내 기포율 측정을 위한 선행 연구)

  • Lee, Sun-Young;Oh, Oh-Sung;Lee, Se-Ho;Lee, Seung-Wook
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.571-578
    • /
    • 2017
  • Bubbles are generated by the boiling of the cooling water when an accident occurs in the reactor and then in order to measure the void fraction, the Optical Fiber Probe(OFP) and optical camera are used in thermal hydraulic safety research. However, such an optical method is not suitable for measuring the void fraction in a $17{\times}17$ array of fuel rods due to the geometrical limitations. This study was conducted as a preliminary study using x-ray system and various phantoms before applying to rod bundles. Through radiographic and tomographic experiments, the tube voltage of the x-ray generator was 130 kVp and the tube current was 1 mA. In addition, it is possible to measure the hole of 1mm in size visually through the bubble resolution phantom, and it is confirmed that the contrast is relatively decreased in the inside of the freon in the case of the contrast evaluation using the road phantom. However, we could obtain good image without distortion when reconstructing the image. Bubble generation phantom experiments were used to confirm the flow direction of the bubbles and to acquire tomography images. The image J tool was used to measure the void fraction of 18 % for a single tomography image. This study has carried out previous researches for the measurement of the bubble rate around the nuclear fuel and could be used as a basic research for continuous research.

Improvement of Inspection Methods using Lighting Signals and Guidebook for Non-English speaking Foreign Visitors (For chest X-ray Screening Examinees) (비영어권 외국인 내원객의 조명 신호와 안내서를 이용한 검사방법 개선 효과(흉부 방사선 검사자를 대상으로))

  • Kwak, Jong Hyeok;Choi, Min Gyeong;Kim, Neung Kyun;Kim, A Yeon;Kim, Gyeong Rip
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.577-584
    • /
    • 2020
  • In this study, the number of non-English speaking visitors is increasing day by day, and accordingly, there was a limitation in language communication and communication during radiographic examination. To this end, after distributing the handbook produced for inspection, the improvement effect of before and after explanation was examined. The score scale was not statistically significant as to whether it was the test site or not, and the degree of discomfort of the test, the degree of understanding of the breathing guidelines, and the satisfaction of the test description were improved and the score scale was improved before and after the description of the guide. Non-English-speaking foreign visitors were more satisfied with explanations in their own text than in English or Korean, and the method was also able to conduct effective inspections by informing the foreign guests when to control their breathing by using the lighting signals in the laboratory. In the future, the quality of medical services and imaging medical examinations can be improved only when communication methods are implemented from various perspectives, such as developing various language interpretation programs, developing guides for various test sites, and developing tools and improving foreign language skills of radiologists and medical staff. There will be. In the future, it may be used as a basic resource to prepare a manual that can be used to examine non-English speaking foreigners who do not understand English or Korean in other radiology labs.

The Ability of FDG Uptake Ratio and Glut-1 Expression to Predict Mediastinal Lymph Node Metastasis in Resected Non-small Cell Lung Cancer (절제된 비소세포암에서 FDG 섭취비와 Glut-1 발현 정도를 이용한 종격동 림프선 전이 여부 예측)

  • Cho, Suk-Ki;Lee, Eung-Bae
    • Journal of Chest Surgery
    • /
    • v.43 no.5
    • /
    • pp.506-512
    • /
    • 2010
  • Background: This study was designed to evaluate the FDG uptake ratio of mediastinal node and primary tumors using integrated PET/CT imaging combined with Glut-1 expression of the primary tumor in order to predict the N2 status more accurately in NSCLC patients. Material and Method: Patients who underwent integrated PET/CT scanning with a detectable mSUV for both primary tumors and mediastinal lymph nodes were eligible for this study. The FDG uptake ratio between the mediastinal node and the primary tumor was calculated. Result: The average mSUV of primary tumors and mediastinal nodes were, respectively, $7.4{\pm}2.2$ and $4.2{\pm}2.2$ in N2-positive patients and $7.6{\pm}3.7$ and $2.8{\pm}6.9$ in N2-negative patients. The mean FDG uptake ratio of mediastinal node to primary tumor were $0.58{\pm}0.23$ for malignant N2 lymph nodes and $0.45{\pm}0.20$ for benign lymph nodes (p<0.05). Models which combined Glut-1 expression with an FDG ratio have better diagnostic power than models that use the FDG uptake ratio alone. Conclusion: In some patients with a previous history of pulmonary tuberculosis or other inflammatory lung diseases, an FDG uptake ratio combined with Glut-1 expression may be useful in diagnosing mediastinal node metastasis more exactly.

Clinical analysis and review of literature on pilomatrixoma in pediatric patients

  • Hu, Ju Long;Yoo, Hyokyung;Kwon, Sung Tack;Kim, Sukwha;Chung, Jee Hyeok;Kim, Hyeonwoo;Kim, Jinhyun;Yu, Na Hee;Kim, Byung Jun
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.5
    • /
    • pp.288-293
    • /
    • 2020
  • Background: Pilomatrixoma is a benign tumor that originates from the hair follicle matrix. It usually presents as a hard, slow growing, solitary mass that can be easily misdiagnosed as other skin masses. The aim of this study was to clinically analyze a case series of pilomatrixoma in pediatric patients from Korea. Methods: A total of 165 pediatric patients from 2011 to 2018 with a histological diagnosis of pilomatrixoma were included. A retrospective review was performed using the electronic medical records, including patient demographics, number and location of the mass, clinical and imaging presentation, and postoperative outcomes. Results: There were 61 male and 104 female patients with 152 solitary and 13 multiple pilomatrixomas. Among solitary pilomatrixomas, the lesion commonly occurred in the head and neck (84.2%), followed by upper limbs (11.2%), lower limbs (3.3%), and trunk (1.3%). The pilomatrixoma lesion presented as the following types based on our clinical classification: mass (56.02%), pigmentation (25.31%), mixed (12.65%), ulceration (4.82%), and keloid-like (1.2%). Ultrasonography showed a high positive predictive value (95.56%). There were no specific complications observed except for two cases of recurrence. Conclusion: Pilomatrixoma has various clinical feature presentations and commonly occurs in the head and neck. Ultrasonography is a helpful diagnostic tool. Surgical removal of the lesion is the main treatment method with a low recurrence rate.

A Study on the Gamut Mapping Method of the Wide Gamut Display Device (광 색역 디스플레이 장치의 색역 사상에 관한 연구)

  • Um Jinsub;Shin Yoonchol;Kim Moonchol
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.2 s.302
    • /
    • pp.69-80
    • /
    • 2005
  • In these days, the technology development of the imaging/optic industry and the digital broadcasting replace the classic CRT with the new display devices that is getting slimmer and larger. Especially, when the general TV signal is applied directly to the wide gamut display using LED or laser, which can display higher chromatic colors that can't be reproduced on CRT, the color distortion occurs and it causes serious problems. Thus, in this paper the gamut mapping is studied, which gets rids of the color distortion and utilizes the wider color gamut than that of the CRT sufficiently. In the gamut mapping the general mapping concept is the increasement of the chroma on the same hue plane but it causes the over chromatic enhancement. So, the vector mapping, which increases the lightness md the chroma at the same time, is proposed to prevent the side effect. In the vector mapping the chromaticity is maintained constantly, hence the image can be seen more natural than that of the chroma mapping. By using the gamut fitting, it is compensated that the tone disappearance or the contour effect that is arose from the geometric properties of the input and the output color gamut. These gamut mapping and gamut fitting can prevent the color distortion and reproduce the natural image on the wide gamut displays.

Optimal Echo phase of FLASH sequence for Brain Enhancement scan of mouse at 9.4T MRI system (9.4T MRI FLASH Sequence에서 마우스의 뇌 조영증강 검사를 위한 적정 Echo phase)

  • Jeong, Hyunkeun;Kim, Mingi;Nam, Kichang;Jung, Hyundo;Ahn, Chigwon;Kim, Hochul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.115-124
    • /
    • 2017
  • The objective of study was to investigate the optimal echo phase for mouse brain enhancement scan using fast low angle shot (FLASH) sequence of 9.4T magnetic resonance imaging (MRI). For quantification based on this method, an MR phantom experiment and clinical research were done. The phantom experiment was conducted by fabricating three phantoms with different molar concentration of gadolinium to create changes in echo phase of 9.4T FLASH sequence used in mouse brain scans. In the phantom experiment, SSI was 25~27 [arbitrary units, a.u.] in each of 33 phases from $6{\pi}$ to $28{\pi}$, while RSP was 30~100 mmol. MPSI was 47~52 [a.u], while MPP, where MPSI is seen, was 0.8~9 mmol. EPMS was 80.8~108.0%, while ASIMP was formed between 21.1 and 31.8 [a.u]. In the clinical research, Finally, the occurrence rate of artifact that expressed -1 nd +1. The present study was able to quantify the degree of enhancement at FLASH sequence of 9.4T MRI, as well as identify the optimal echo phase during mouse brain enhancement scan.

Contrast Enhanced Cerebral MR Venography: Comparison between Arterial and Venous Triggering Methods (조영 증강 자기공명정맥 촬영술에서의 동맥과 정맥 triggering 방법의 비교)

  • Jang, Min-Ji;Choi, Hyun-Seok;Jung, So-Lyung;Ahn, Kook-Jin;Kim, Bum-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.2
    • /
    • pp.152-158
    • /
    • 2012
  • Purpose : To compare the arterial and venous detection sites of triggering methods in contrast-enhanced-MR-venography (CE-MRV) for the evaluation of intracranial venous system. Materials and Methods: 41 healthy patients underwent CE-MRV with autotriggering at either the cavernous segment of internal carotid artery with an inserted time-delay of 6 seconds (n = 20) or the superior sagittal sinus without any timedelay (n = 21). 0.1 mmol/kg gadolinium-based contrast material ($Magnevist^{(R)}$, Schering, Germany) was intravenously injected by hand injection. A sagittal fast-spoiled-gradient-echo-sequence ranging from one ear to the other was performed (TR/TE5.2/1.5, Matrix $310{\times}310$, 124 sections in the 15-cm-thick volume). 17 predefined venous structures were evaluated on all venograms by two neuroradiologists and defined as completely visible, partially visible, or none visible. Results: The rate of completely visible structures were 272 out of 323 (84%) in the arterial triggering CE-MRV and 310 out of 340 (91%) in the venous triggering CE-MRV. The venous triggering CE-MRV demonstrated an overall superior visualization of the cerebral veins than the arterial triggering CE-MRV (Fisher exact test, p < 0.006). Conclusion: CE-MRV using venous autotriggering method provides higher-quality images of the intracranial venous structures compared to that of arterial.