• 제목/요약/키워드: Imaging Process

검색결과 1,037건 처리시간 0.052초

Study on Characteristic difference of Semiconductor Radiation Detectors fabricated with a wet coating process

  • Choi, Chi-Won;Cho, Sung-Ho;Yun, Min-Suk;Kang, Sang-Sik;Park, Ji-Koon;Nam, Sang-Hee
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.192-193
    • /
    • 2006
  • The wet coating process could easily be made from large area film with printing paste mixed with semiconductor and binder material at room temperature. Semiconductor film fabricated about 25mm thickness was evaluated by field emissions-canning electron microscopy (FE-SEM). X-ray performance data such as dark current, sensitivity and signal to noise ratio (SNR) were evaluated. The $Hgl_2$ semiconductor was shown in much lower dark current than the others, but the best sensitivity. In this paper, reactivity and combination character of semiconductor and binder material that affect electrical and X-ray detection properties would prove out though experimental results.

  • PDF

수중음향 영상화를 위한 렌즈 제작 및 특성 평가 (Characteristics Evaluation of the Lens for Underwater Acoustic Imaging)

  • 조완호;권휴상;조요한;서희선
    • 한국소음진동공학회논문집
    • /
    • 제26권6_spc호
    • /
    • pp.687-696
    • /
    • 2016
  • A series of process to design an acoustic lens for underwater imaging is reviewed and the method to evaluate characteristics of the lens is investigated. If the target specification of lens is given, the design process consists of the material selection, evaluation of its properties, lens geometry design, prediction of lens characteristics, manufacturing, and evaluation by measurement. In this study, an actual acoustical lens is made by cutting polymethylpentene block. The characteristics of lens are predicted by the hybrid method, combination of ray tracing and Rayleigh integral. For the direct comparison between the prediction and measurement results, a simulation method based on the equivalent source method is suggested to reflect the actual radiation pattern of transducer used for measurements. Finally, the measurement is conducted in a small water tank to observe the actual characteristics of the manufactured lens.

원형매핑 모델과 보간법을 복합 사용하는 컴퓨터 집적 영상 복원 기술에서 3D 영상의 해상도 개선 (Enhancement of 3D image resolution in computational integral imaging reconstruction by a combination of a round mapping model and interpolation methods)

  • 신동학;유훈
    • 한국정보통신학회논문지
    • /
    • 제12권10호
    • /
    • pp.1853-1859
    • /
    • 2008
  • 본 논문에서는 컴퓨터 집적 영상 복원(CIIR) 기법 기반의 3D 패턴 인식 응용을 위해서 평 면 3D 복원 영상의 해상도를 향상시키는 새로운 방식을 제안한다. 제안하는 방식에서는 ClIR에서 각각의 요소 영상에 대해서 원형 매핑 모델과 보간법을 복합사용하여 확대 중첩을 통해 향상된 3D 영상을 복원한다. 제안하는 방식에 대해서 정확한 CIIR 방식의 객관적인 해석을 위해서 Gaussian 영상을 이용한 테스트 모델을 설명하고 제안하는 방식에 대해서 성능평가를 수행한다. 그리고 3차원 물체에 대한 컴퓨터 복원 실험을 수행하고 그 결과를 보고한다.

Similarity analysis of pixelated CdTe semiconductor gamma camera image using a quadrant bar phantom for nuclear medicine: Monte Carlo simulation study

  • Park, Chan Rok;Kang, Seong-Hyeon;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.1947-1954
    • /
    • 2021
  • In the nuclear medicine imaging, quality control (QC) process using quadrant bar phantom is fundamental aspect of evaluating the spatial resolution. In addition, QC process of gamma camera is performed by daily or weekly. Recently, Monte Carlo simulation using the Geant4 application for tomographic emission (GATE) is widely applied in the pre-clinical nuclear medicine field for modeling gamma cameras with pixelated cadmium telluride (CdTe) semiconductor detector. In this study, we modeled a pixelated CdTe semiconductor detector and quadrant bar phantom (0.5, 1.0, 1.5, and 2.0 mm bar thicknesses) using the GATE tool. Similarity analysis based on correlation coefficients and peak signal-to-noise ratios was performed to compare image qualities for various source to collimator distances (0, 2, 4, 6, and 8 cm) and collimator lengths (0.2, 0.4, 0.6, 0.8, and 1.0 cm). To this end, we selected reference images based on collimator length and source to collimator distance settings. The results demonstrate that as the collimator length increases and the source to collimator distance decreases, the similarity to reference images improves. Therefore, our simulation results represent valuable information for the modeling of CdTe-based semiconductor gamma imaging systems and QC phantoms in the field of nuclear medicine.

단일 주파수 시간조화 신호원을 사용한 도체기둥의 incoherent 단면영상법 (Incoherent Tomography for Conducting Cylinder by Using Single-Frequency Time-Harmonic Source)

  • 강진섭;라정웅
    • 전자공학회논문지D
    • /
    • 제35D권1호
    • /
    • pp.1-7
    • /
    • 1998
  • In this paper, an incoherent imaging of a conducting cylinder illuminated by the single-frequency time-harmonic plane wave is obtained via the back-projections of the intensity patterns of the forward total electric field scattered from this object in the circular rotational measurement configuration. The pheonmenon that interference fringes generated in the itesity patterns is removed in the back-projection process is interpreted numerically. This imaging method is validated by imagining conducting circular cylinders and the conditions to ge beter image are investigated.

  • PDF

Image Analysis for Detection of Defects of BGA by Using X-ray Imaging

  • Sumimoto, Tetsuhiro;Maruyama, Toshinori;Azuma, Yoshiru;Goto, Sachiko;Mondou, Munehiro;furukwa, Noboru;Okada, Saburo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.87.5-87
    • /
    • 2002
  • . A high peak power demand at substations will result under This paper deals with the detection of defects at BGA solder joints in PC boards by using X-ray Imaging. . To improve a cost performance and reliability of PC boards, an inspection of BGA is required in the surface mount process. . Contents 2 We attempt to detect the characteristic of the solder bridges based on an image analysis.

  • PDF

Imaging and Manipulation of Benzene Molecules on Si Surfaces Using a Variable-low Temperature Scanning Tunneling Microscope

  • Hahn, J. R.
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권7호
    • /
    • pp.1071-1074
    • /
    • 2005
  • A variable-low temperature scanning tunneling microscope (VT-STM), which operates from 77 to 350 K in ultrahigh vacuum, was built and used to study imaging and manipulation of benzene molecules on Si surfaces. Four types of benzene adsorption structures were first imaged on the Si(5 5 12)-2x1 surface. Desorption process of benzene molecules by tunneling electrons was studied on the Si(001)-2xn surface.

Foramen transversarium enlargement caused by vertebral artery tortuosity: Diagnosis with cone-beam computed tomography and magnetic resonance angiography

  • Omami, Galal
    • Imaging Science in Dentistry
    • /
    • 제51권3호
    • /
    • pp.329-332
    • /
    • 2021
  • A markedly enlarged foramen transversarium was discovered incidentally on a cone-beam computed tomography scan of a 72-year-old male patient who was referred for dental implant placement. Further evaluation with magnetic resonance angiography revealed that the foramen enlargement was caused by a tortuosity in the course of the vertebral artery. This case report highlights the importance of recognizing significant incidental findings on diagnostic images and the potential need for additional imaging as part of the complete interpretative process.

IMAGING SPECTROMETRY FOR DETECTING FECES AND INGESTA ON POULTRY CARCASSES

  • Park, Bo-Soon;William R.Windham;Kurt C.Lawrence;Smith, Douglas-P
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.3106-3106
    • /
    • 2001
  • Imaging spectrometry or hyperspectral imaging is a recent development that makes possible quantitative and qualitative measurement for food quality and safety. This paper presents the research results that a hyperspectral imaging system can be used effectively for detecting fecal (from duodenum, cecum, and colon) and ingesta contamination on poultry carcasses from the different feed meals (wheat, mile, and corn with soybean) for poultry safety inspection. A hyperspectral imaging system has been developed and tested for the identification of fecal and ingesta surface contamination on poultry carcasses. Hypercube image data including both spectral and spatial domains between 430 and 900 nm were acquired from poultry carcasses with fecal and ingesta contamination. A transportable hyperspectral imaging system including fiber optically fabricated line lights, motorized lens control for line scans, and hypercube image data from contaminated carcasses with different feeds are presented. Calibration method of a hyperspectral imaging system is demonstrated using different lighting sources and reflectance panels. Principal Component and Minimum Noise Fraction transformations will be discussed to characterize hyperspectral images and further image processing algorithms such as image band ratio of dual-wavelength images and its histogram stretching with thresholding process will be demonstrated to identify fecal and ingesta materials on poultry carcasses. This algorithm could be further applied for real-time classification of fecal and ingesta contamination on poultry carcasses in the poultry processing line.

  • PDF

집적 영상을 활용한 3차원 QR code (Three-dimensional QR Code Using Integral Imaging)

  • 김영준;조기옥;한재승;조명진
    • 한국정보통신학회논문지
    • /
    • 제20권12호
    • /
    • pp.2363-2369
    • /
    • 2016
  • 본 논문에서는 집적 영상과 컴퓨터 재생 기술을 활용한 3차원 QR 코드 생성 기술을 제안한다. 제안하는 기술에서는 2차원 QR 코드를 네 개의 면으로 나누어 각각의 면을 서로 다른 깊이에 배치한 뒤 깊이가 추가된 3차원 QR 코드를 합성조리개 집적 영상과 컴퓨터 재생 기술을 사용하여 생성한다. 이 과정에서 3차원 영상 기술 중 하나인 집적 영상 기술을 사용한다. 마지막으로, 3차원 QR 코드를 집적영상을 이용하여 컴퓨터 재생을 한 뒤 각 면을 배치했던 깊이 부분에서 영상을 재생하고 조합하면 3차원 QR 코드를 읽을 수 있다. 따라서 QR 코드를 읽을 때 보안을 강화할 수 있다. 본 논문에서는 제안된 기술이 QR 코드를 읽을 때 보안을 강화할 수 있음을 보이기 위하여 광학적 실험과 컴퓨터 재생을 수행하였다. 또한, 재생 깊이를 알고 있을 때, 3차원 QR 코드를 읽을 수 있음을 보였다.