• Title/Summary/Keyword: Image Uniformity

Search Result 260, Processing Time 0.033 seconds

Quantum Nanostructure of InGaAs on Submicron Gratings by Constant Growth Technique

  • Son, Chang-Sik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.12
    • /
    • pp.1027-1031
    • /
    • 2001
  • A new constant growth technique to conserve an initial grating height of V-groove AlGaAs/InGaAs quantum nanostructures above 1.0 $\mu\textrm{m}$ thickness has been successfully embodied on submicron gratings using low pressure metalorganic chemical vapor deposition. A GaAs buffer prior to an AlGaAs barrier layer on submicron gratings plays an important role in overcoming mass transport effects and improving the uniformity of gratings. Transmission electron microscopy (TEM) image shows that high-density V-groove InGaAs quantum wires (QWRs) are well confined at the bottom of gratings. The photoluminescence (PL) peak of the InGaAs QWRs is observed in the temperature range from 10 to 280 K with a relatively narrow full width at half maximum less than 40 meV at room temperature PL. The constant growth technique is an important step to realize complex optoelectronic devices such as one-step grown distributed feedback lasers and two-dimensional photonic crystal.

  • PDF

A Spatial Regularization of LDA for Face Recognition

  • Park, Lae-Jeong
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.10 no.2
    • /
    • pp.95-100
    • /
    • 2010
  • This paper proposes a new spatial regularization of Fisher linear discriminant analysis (LDA) to reduce the overfitting due to small size sample (SSS) problem in face recognition. Many regularized LDAs have been proposed to alleviate the overfitting by regularizing an estimate of the within-class scatter matrix. Spatial regularization methods have been suggested that make the discriminant vectors spatially smooth, leading to mitigation of the overfitting. As a generalized version of the spatially regularized LDA, the proposed regularized LDA utilizes the non-uniformity of spatial correlation structures in face images in adding a spatial smoothness constraint into an LDA framework. The region-dependent spatial regularization is advantageous for capturing the non-flat spatial correlation structure within face image as well as obtaining a spatially smooth projection of LDA. Experimental results on public face databases such as ORL and CMU PIE show that the proposed regularized LDA performs well especially when the number of training images per individual is quite small, compared with other regularized LDAs.

The Influence of Collimators on SPECT COR Measurements (SPECT 회전중심 측정에 있어서 콜리메타의 영향)

  • Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.19 no.1
    • /
    • pp.89-94
    • /
    • 1996
  • Misalignment between the electronic and mechanical axes of rotation will result in artifact generation and image degradation during single photon emission computed tomography(SPECT) reconstruction. Acceptance and quality control testing procedures have not emphasized the variability in center of rotation(COR) measurements caused by collimators and the need to verify uniformity across the full collimator field of view (FOV). Variation from the mean COR across the FOV was tested in four different collimators using multiple point source acquisitions. The mean COR was different for each collimator and one of the four had a > 0.5 pixel difference from the mean COR on some area of the FOV, This variation makes this collimator unacceptable for SPECT acquisition. Thus, initial acceptance testing of SPECT collimators should verify a uniform COR across the full FOV and collimators with a variability from the mean COR > 0.5 pixels should be rejected.

  • PDF

Intensity non-uniformity correction with k-space data

  • 김양현;류완석;김대원;류택현;최환준;김시승;현정호;정성택
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.98-98
    • /
    • 2002
  • 목적: RF Coil sensitivity 또는 MRI system의 여러 요인들로 인해서 생길 수 있는 영상의 Bias field 즉, 유난히 밝거나 어두운 부분을 raw data 의 low frequency 값들을 임의로 변화를 줌으로써 어느 정도 보정이 가능하다. 대상 및 방법: Bias field로 인해서 분석에 어려움이 있는 이미지의 k-space 데이터를 가지고 있으면 부위에 상관없이 모두 가능하다. k-space에서 얻어진 raw data를 Kx와 Ky의 2-D로 표현한 후에 DC 성분에 해당하는 영점을 그대로 놔둔 상태에서 영점 주변으로 일정 범위 안에 있는 low frequency 성분 값들을 FT(Fourier Transform)를 거치기 전에 0으로 바꾼 후에 image processing을 거치도록 한다.

  • PDF

Quantitative Evaluation Method for Etch Sidewall Profile of Through-Silicon Vias (TSVs)

  • Son, Seung-Nam;Hong, Sang Jeen
    • ETRI Journal
    • /
    • v.36 no.4
    • /
    • pp.617-624
    • /
    • 2014
  • Through-silicon via (TSV) technology provides much of the benefits seen in advanced packaging, such as three-dimensional integrated circuits and 3D packaging, with shorter interconnection paths for homo- and heterogeneous device integration. In TSV, a destructive cross-sectional analysis of an image from a scanning electron microscope is the most frequently used method for quality control purposes. We propose a quantitative evaluation method for TSV etch profiles whereby we consider sidewall angle, curvature profile, undercut, and scallop. A weighted sum of the four evaluated parameters, nominally total score (TS), is suggested for the numerical evaluation of an individual TSV profile. Uniformity, defined by the ratio of the standard deviation and average of the parameters that comprise TS, is suggested for the evaluation of wafer-to-wafer variation in volume manufacturing.

Fused Illumination Mechanism Design for Steel Plate Surface Inspection (철강 후판의 표면 검사를 위한 융합조명계 설계)

  • Cho, Eun Doek;Kim, Gyung Bum
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.3
    • /
    • pp.14-19
    • /
    • 2017
  • In this paper, a fused illumination mechanism for detecting surface defects in steel plates was designed by applying the discriminant function that can differentiate the contrast of defects and non-defects. There is low contrast, non-uniformity, and no feature characteristics in steel plate surfaces. The fused illumination mechanism is devised, based on those characteristics. Optimum parameters of the fused illumination mechanism are determined by applying the discriminant function after acquiring the defect image in steel plate surfaces. The performance of the proposed mechanism is verified by experminets.

  • PDF

A Study on the Correlation between Temperature and CMP Characteristics (CMP특성과 온도의 상호관계에 관한 연구)

  • Gwon, Dae-Hui;Kim, Hyeong-Jae;Jeong, Hae-Do;Lee, Eung-Suk;Sin, Yeong-Jae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.10
    • /
    • pp.156-162
    • /
    • 2002
  • There are many factors affecting the results of CMP (Chemical Mechanical Polishing). Among them, the temperature is related to the removal rate and WIWNU (Within Wafer Non-Uniformity). In other words, the removal rate is proportional to the temperature and the variation of temperature distribution on a pad affects the non-uniformity within a wafer. In the former case, the active chemistry improves the rate of chemical reaction and the removal rate becomes better. But, there are not many advanced studies. In the latter case, a kinematical analysis between work-piece and pad can be obtained. And such result analysed from the mechanical aspect can be directly related to the temperature distribution on a pad affecting WIWNU. Meanwhile, the temperature change affects the quantities of both slurry and pad. The change of a pH value of the slurry chemistry due to a temperature variation affects the surface state of an abrasive particle and hence the agglomeration of abrasives happens above the certain temperature. And the pH alteration also affects the zeta potential of a pad surface and therefore the electrical force between pad and abrasive changes. Such results could affect the removal rate and etc. Moreover, the temperature changes the 1st and 2nd elastic moduli of a pad which are closely related to the removal rate and the WIWNU.

Comparison of Composite Methods of Satellite Chlorophyll-a Concentration Data in the East Sea

  • Park, Kyung-Ae;Park, Ji-Eun;Lee, Min-Sun;Kang, Chang-Keun
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.6
    • /
    • pp.635-651
    • /
    • 2012
  • To produce a level-3 monthly composite image from daily level-2 Sea-viewing Wide Field-of-view Sensor (SeaWiFS) chlorophyll-a concentration data set in the East Sea, we applied four average methods such as the simple average method, the geometric mean method, the maximum likelihood average method, and the weighted averaging method. Prior to performing each averaging method, we classified all pixels into normal pixels and abnormal speckles with anomalously high chlorophyll-a concentrations to eliminate speckles from the following procedure for composite methods. As a result, all composite maps did not contain the erratic effect of speckles. The geometric mean method tended to underestimate chlorophyll-a concentration values all the time as compared with other methods. The weighted averaging method was quite similar to the simple average method, however, it had a tendency to be overestimated at high-value range of chlorophyll-a concentration. Maximum likelihood method was almost similar to the simple average method by demonstrating small variance and high correlation (r=0.9962) of the differences between the two. However, it still had the disadvantage that it was very sensitive in the presence of speckles within a bin. The geometric mean was most significantly deviated from the remaining methods regardless of the magnitude of chlorophyll-a concentration values. Its bias error tended to be large when the standard deviation within a bin increased with less uniformity. It was more biased when data uniformity became small. All the methods exhibited large errors as chlorophyll-a concentration values dominantly scatter in terms of time and space. This study emphasizes the importance of the speckle removal process and proper selection of average methods to reduce composite errors for diverse scientific applications of satellite-derived chlorophyll-a concentration data.

Novel optical representation of binary data to improve the beam intensity uniformity at the recording plane in the storage of Fourier holograms of digital data (디지털 데이터의 Fourier 홀로그램 저장에서 기록면의 빔세기 균일도 향상을 위한 2진 데이터의 새로운 광학적 표현)

  • 장주석;신동학;오용석
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.4
    • /
    • pp.339-344
    • /
    • 2001
  • We propose a method to represent binary data by modulating both the intensity and the phase of uniform plane waves with a twisted-nematic liquid crystal display for holographic digital data storage especially in a disk-shaped recording medium. As far as intensity modulation is concerned, our method is not different from the conventional method, because binary bit values 0 and 1 are represented by the dark (off) and lit (on) states of the liquid crystal display pixels, respectively (or vice versa). With our method, however, the on pixels are also controlled so that the beams passing through them can have one of two different phase delays. If the difference of the two phase delays is close to 180 degrees, we can reduce the dc component of the data image and thus improve the beam intensity uniformity at the holographic recording plane when Fourier plane holograms are recorded. The feasibility of our method is experimentally demonstrated. rated.

  • PDF

Polishing Characteristics of passivation layer by abrasive particles and slurry chemical in the Metal CMP process (금속 CMP 공정에서 연마제와 슬러리 케미컬에 의한 passivation layer의 연마특성)

  • Park, Chang-Jun;Seo, Yong-Jin;Lee, Kyoung-Jin;Jeong, So-Young;Kim, Sang-Yong;Lee, Woo-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.45-48
    • /
    • 2003
  • The polishing mechanism of W-CMP process has been reported as the repeated process of passive layer formation by oxidizer and abrasion action by slurry abrasives. Thus, it is important to understand the effect of oxidizer on tungsten passivation layer in order to obtain higher removal rate (RR) and very low non-uniformity (NU%) during W-CMP process. In this paper, we investigated the effects of oxidizer on W-CMP process with three different kinds of oxidizers, such as $H_2O_2$, $Fe(NO_3)_3$, and $KIO_3$. In order to compare the removal rate and non-uniformity of three oxidizers, we used alumina-based slurry of pH 4. According to the CMP tests, three oxidizers showed different removal mechanism on tungsten surface. Also, the microstructures of surface layer by AFM image were greatly influenced by the slurry chemical, composition of oxidizers. The difference in removal rate and roughness of tungsten surface are believed to caused by modification in the mechanical behavior of $Al_2O_3$ abrasive particles in CMP slurry. Our stabilized slurries can be used a guideline and promising method for improved W-CMP process.

  • PDF