• 제목/요약/키워드: Image Specification

Search Result 180, Processing Time 0.024 seconds

DEVELOPMENT OF CCD IMAGING SYSTEM USING THERMOELECTRIC COOLING METHOD (열전 냉각방식을 이용한 극미광 영상장비 개발)

  • Park, Young-Sik;Lee, Chung-Woo;Jin, Ho;Han, Won-Yong;Nam, Uk-Won;Lee, Yong-Sam
    • Journal of Astronomy and Space Sciences
    • /
    • v.17 no.1
    • /
    • pp.53-66
    • /
    • 2000
  • We developed low light CCD imaging system using thermoelectric cooling method collaboration with a company to design a commercial model. It consists of Kodak KAF-0401E(768$\times$512 pixels) CCD chip, thermoelectric module manufactured by Thermotek. This TEC system can reach an operative temperature of $-25^{\circ}C$. We employed an Uniblitz VS25s shutter and it has capability a minimum exposure time 80ms. The system components are an interface card using a Korea Astronomy Observatory (hereafter KAO) ISA bus controller, image acquisition with AD9816 chip, that is 12bit video processor. The performance test with this imaging system showed good operation within the initial specification of our design. It shows a dark current less than 0.4e-/pixel/sec at a temperature of $-10^{\circ}C$, a linearity 99.9$\pm$0.1%, gain 4.24e-/adu, and system noise is 25.3e-(rms). For low temperature CCD operation, we designed a TEC, which uses a one-stage peltier module and forced air heat exchanger. This TEC imaging system enables accurate photometry($\pm$0.01mag) even though the CCD is not at 'conventional' cryogenic temperatures(140k). The system can be a useful instrument for any other imaging applications. Finally, with this system, we obtained several images of astronomical objects for system performance tests.

  • PDF

A Study on Automatic Precision Landing for Small UAV's Industrial Application (소형 UAV의 산업 응용을 위한 자동 정밀 착륙에 관한 연구)

  • Kim, Jong-Woo;Ha, Seok-Wun;Moon, Yong-Ho
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.3
    • /
    • pp.27-36
    • /
    • 2017
  • In almost industries, such as the logistics industry, marine fisheries, agriculture, industry, and services, small unmanned aerial vehicles are used for aerial photographing or closing flight in areas where human access is difficult or CCTV is not installed. Also, based on the information of small unmanned aerial photographing, application research is actively carried out to efficiently perform surveillance, control, or management. In order to carry out tasks in a mission-based manner in which the set tasks are assigned and the tasks are automatically performed, the small unmanned aerial vehicles must not only fly steadily but also be able to charge the energy periodically, In addition, the unmanned aircraft need to land automatically and precisely at certain points after the end of the mission. In order to accomplish this, an automatic precision landing method that leads landing by continuously detecting and recognizing a marker located at a landing point from a video shot of a small UAV is required. In this paper, it is shown that accurate and stable automatic landing is possible even if simple template matching technique is applied without using various recognition methods that require high specification in using low cost general purpose small unmanned aerial vehicle. Through simulation and actual experiments, the results show that the proposed method will be made good use of industrial fields.

Developmental disability Diagnosis Assessment Systems Implementation using Multimedia Authorizing Tool (멀티미디어 저작도구를 이용한 발달장애 진단.평가 시스템 구현연구)

  • Byun, Sang-Hea;Lee, Jae-Hyun
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.3 no.1
    • /
    • pp.57-72
    • /
    • 2008
  • Serve and do so that graft together specialists' view application field of computer and developmental disability diagnosis estimation data to construct developmental disability diagnosis estimation system in this Paper and constructed developmental disability diagnosis estimation system. Developmental disability diagnosis estimation must supply information of specification area that specialists are having continuously. Developmental disability diagnosis estimation specialist system need multimedia data processing that is specialized little more for developmental disability classification diagnosis and decision-making and is atomized for this. Characteristic of developmental disability diagnosis estimation system that study in this paper can supply quick feedback about result, and can reduce mistake on recording and calculation as well as can shorten examination's enforcement time, and background of training is efficient system fairly in terms of nonprofessional who is not many can use easily. But, as well as when multimedia information that is essential data of system construction for developmental disability diagnosis estimation is having various kinds attribute and a person must achieve description about all developmental disability diagnosis estimation informations, great amount of work done is accompanied, technology about equal data can become different according to management. Because of these problems, applied search technology of contents base (Content-based) that search connection information by contents of edit target data for developmental disability diagnosis estimation data processing multimedia data processing technical development. In the meantime, typical access way for conversation style data processing to support fast image search, after draw special quality of data by N-dimension vector, store to database regarding this as value of N dimension and used data structure of Tree techniques to use index structure that search relevant data based on this costs. But, these are not coincided correctly in purpose of developmental disability diagnosis estimation because is developed focusing in application field that use data of low dimension such as original space DataBase or geography information system. Therefore, studied save structure and index mechanism of new way that support fast search to search bulky good physician data.

  • PDF

Design of Single Balanced Diode Mixer with Filter for Improving Band Flatness in Microwave Frequency Down Converter (마이크로파 주파수 하향 변환기에서의 대역 평탄도 개선을 위한 여파기 집적형 단일 평형 다이오드 혼합기 설계)

  • Ryu, Seung-Kab;Hwang, In-Ho;Han, Seok-Kyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.1 s.116
    • /
    • pp.37-43
    • /
    • 2007
  • In this.paper, we introduce design and implementation results of the single balanced diode mixer for European point-to-point microwave radio in order to improve flatness performance. When a resonator such as RF filter is integrated with a mixer, impedance characteristic of 50 ohm is maintained only in RF band, not in LO band resulting deterioration of flatness performance because of LO power variation on the diode. In the paper, we suggest a design method of mixer integrated with image rejection filter and LO harmonic filter to have a better performance of flatness using embedding electrical length between filter and mixer's port. Frequency specification of fabricated mixer is $21.2{\sim}22.6\;GHz$ for RF, $19.32{\sim}20.72\;GHz$ for LO and 1.88 GHz+/-50 MHz for IF, respectively. Measured results show conversion loss of 8.5 dB, flatness of 2 dB, input PldB of 8 dBm, IIP3 of 15 dBm under LO power level of 10 dBm. Return losses of RF, LO and IF port are under -12 dB, -10 dB and -5 dB, respectively. Isolations of LO/RF and LO/IF are 20 dB and 50 dB, respectively.

A Study on u-CCTV Fire Prevention System Development of System and Fire Judgement (u-CCTV 화재 감시 시스템 개발을 위한 시스템 및 화재 판별 기술 연구)

  • Kim, Young-Hyuk;Lim, Il-Kwon;Li, Qigui;Park, So-A;Kim, Myung-Jin;Lee, Jae-Kwang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.463-466
    • /
    • 2010
  • In this paper, CCTV based fire surveillance system should aim to development. Advantages and Disadvantages analyzed of Existing sensor-based fire surveillance system and video-based fire surveillance system. To national support U-City, U-Home, U-Campus, etc, spread the ubiquitous environment appropriate to fire surveillance system model and a fire judgement technology. For this study, Microsoft LifeCam VX-1000 using through the capturing images and analyzed for apple and tomato, Finally we used H.264. The client uses the Linux OS with ARM9 S3C2440 board was manufactured, the client's role is passed to the server to processed capturing image. Client and the server is basically a 1:1 video communications. So to multiple receive to video multicast support will be a specification. Is fire surveillance system designed for multiple video communication. Video data from the RGB format to YUV format and transfer and fire detection for Y value. Y value is know movement data. The red color of the fire is determined to detect and calculate the value of Y at the fire continues to detect the movement of flame.

  • PDF

Evaluation of Usefulness of SPECT-CT at the Examination of Digestive System Leakage Patients (소화기계 Leakage 환자 검사 시 SPECT-CT의 유용성 평가)

  • Ham, Jun Cheol;Oh, Shin Hyun;Choi, Yong Hoon;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.98-102
    • /
    • 2018
  • Purpose When examining patients with digestive system Leakage, it is not easy to distinguish between bile leakage and bleeding only with Planar images. I would like to evaluate the utility of leakage of bile, confirmation of gastrointestinal bleeding and location discrimination using SPECT-CT. Materials and Methods SPECT-CT was performed according to the request of the reading room after acquiring Planar image for a total of 13 patients, including 8 patients suspected of bile leakage and 5 patients suspected of gastrointestinal bleeding, among patients visiting this specification went. We used Symbia T16 from SIEMENS and Discovery 670 from GE. Planar and SPECT-CT images were evaluated with a score of 1 to 10 by 4 experienced nuclear medicine doctors. Using the sensitivity and the specificity, the evaluation of the inspection by the ROC curve was carried out. The final diagnosis was confirmed by follow-up observation as a result of reoperative surgery. Results The sensitivity, specificity and accuracy of SPECT-CT were 91.7%, 100% and 94.2%, respectively. Planar images were 83.3%, 68.8% and 78.8%, respectively. Planar images showed lower diagnostic accuracy compared to SPECT-CT (78.8%, 94.2%, p<0.05). Moreover, the reliability of the diagnosis of SPECT-CT by ROC curve analysis showed a more useful result than the Planar image (p<0.05). Conclusion SPECT-CT had high sensitivity and specificity for diagnosis of biliary leakage and gastrointestinal bleeding and location discrimination. When SPECT-CT is additionally performed together with Planar images, it may be considered to improve bile leakage and diagnosis of gastrointestinal bleeding patients and position discrimination evaluation. There is usefulness depending on the patient's age and position, but consideration of additional CT exposure may be done sufficiently.

Performance Evaluation of Breast Specific Gamma Imaging (Breast Specific Gamma Imaging 장비의 성능평가)

  • Cha, Eun-Sun;Kwak, In-Suk;Noh, Ik-Sang;Yeon, Joon-Ho;Kim, Ki;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.24-27
    • /
    • 2010
  • Purpose: Early diagnosis of breast is of the utmost importance to improve prognosis. We have a limitation for mammography and sonography detecting small cancer. Clinical importance of Breast Specific Gamma Imaging (BSGI) has improved for that reason. So We studied performance evaluation test of count rate and resolution with high sensitivity to the low dose of BSGI. Materials and Methods: BSGI of Dilon 6800, point source of $^{99m}Tc$ from 1.85~148 MBq (0.05~4 mCi) at the intervals of 1.85~37 MBq (0.05~1 mCi) was used for the test. Performance evaluation method was performed for measuring deadtime for choosing at the 5 different point in the useful field of view (UFOV), acquired image for 60 seconds. Compared with reference of clinical uptake distribution of breast, activity increased according to the distance change 10, 20, 30, 40, 50 mm in the useful field of view. Results: Counting curve increased according to the activity from 1.85 MBq (0.05 mCi) to the 74 MBq (2 mCi), and it change flat shape over 74 MBq (2 mCi). The variation of the full width of half maximum (FWHM) to the distance is 4.05, 4.73, 5.77, 6.90, 8.00, 9.32 mm in 1.85 MBq (0.05 mCi), 4.30, 4.80, 5.90, 7.00, 8.10, 9.07 mm in 3.7 MBq (0.1 mCi), 4.90, 5.60, 6.20, 7.20, 8.20, 9.10 mm in 5.55 MBq (0.15 mCi), 5.30, 6.10, 6.60, 7.00, 7.90, 8.70 mm in 7.40 MBq (0.2 mCi). Conclusion: Distortions of image would be acquired because of the deadtime in BSGI. We found out the fact that specification of $^{99m}Tc$ reaction under 74 MBq (2 mCi) for BSGI. Second, FWHM distribution change from varied distance from the detector, clearly distinguished the location of the lesion.

  • PDF

Analysis on Subjective Image Quality Assessments for 4K-UHD Video Viewing Environments (4K-UHD 비디오 시청환경 특성분석을 위한 주관적 화질평가 분석)

  • Park, In-Kyung;Ha, Kwang-Sung;Kim, Mun-Churl;Cho, Suk-Hee;Cho, Jin-Soo
    • Journal of Broadcast Engineering
    • /
    • v.15 no.4
    • /
    • pp.563-581
    • /
    • 2010
  • In this paper, we perform subjective visual quality assessments on UHD video for UHD TV services and analyze the assessment results. Demands for video services have been increased with availabilities of DTV, Internet and personal media equipments. With this trend, the demands for high definition video have also been increasing. Currently, 2K-HD ($1920{\times}1080$) video have been widely consumed over DTV, DVD, digital camcoders, security cameras and other multimedia terminals in various types, and recently digital cinema contents of 4K-UHD($3840{\times}2160$) have been popularly produced and the cameras, beam projects, display panels that support for 4K-UHD video start to come out into multimedia markets. Also it is expected that 4K-UHD service will appear soon in broadcasting and telecommunications environments. Therefore, in this paper, subjective assessments of visual quality on resolutions, color formats, frame rates and compression rates have been carried to provide basis information for standardization of signal specification of UHD video and viewing environments for future UHDTV. As the analysis on the assessments, UHD video exhibits better subjective visual quality than HD by the evaluators. Also, the 4K-UHD test sequences in YUV444 shows better subjective visual quality than the 4K-UHD test sequences in YUV422 and YUV420, but there is little perceptual difference on 4K-UHD test sequences between YUV422 and YUV420 formats. For the comparison between different frame rates, 4K-UHD test sequences of 60fps gives better subjective visual quality than those of 30fps. For bit-depth comparison, HD test sequences in 10-bit depth were little differentiated from those in 8-bit depth in subject visual quality assessment. Lastly, the larger the PSNR values of the reconstructed 4K-UHD test sequences are, the higher the subjective visual quality is. Against the viewing distances, the differences among encoded 4K-UHD test sequences were less distinguished in longer distances from the display.

PROPERTIES OF CALCIUM HYDROXIDE-EUGENOL COMPOUND (수산화칼슘-유지놀 화합물의 물성)

  • Park, Joon-Chol;Kwon, Tae-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.408-415
    • /
    • 1999
  • When a zinc-oxide eugenol type sealer was placed in root canals treated previously with calcium hydroxide, acceleration of its setting and the yellowish discoloration were observed clinically. The purpose of this study was to evaluate the properties of calcium hydroxide-eugenol compound. Some physical properties of calcium hydroxide-eugenol compound were compared with a manufactured zinc-oxide eugenol based root canal sealer, Tubli-seal$^{(R)}$ in terms of water solubility, water sorption, film thickness and microleakage. Solubility and water sorption were determined by the use of the method described in American Dental Association Specification(ADAS) no. 57. Ten samples of each material were prepared into disks 20mm in diameter and 1.5mm in thickness. The samples were immersed in 50ml of distilled water at $37{\pm}1^{\circ}C$ for 7 days. The samples were then removed and placed in a desiccator. The values for solubility and water sorption were calculated using differences between the weights of same sample. Film thickness was determined by the use of the method described in ADAS no. 57 too. A small quantity of mixed cement was placed between two glass plates of which thickness was measured previously. 15Kg loading was applied and total thickness of the glass plates and the cement film was measured. The thickness difference was recorded as the material's film thickness. Microleakage was determined with a dye penetration method. Experimental materials were placed between the dentin surface of bovine tooth and the acrylic rod. These units were immersed in Pelican ink (W-Germany) for three days. Dye-penetrated dentin surfaces of bovine tooth were measured using the NIB Image 1.60 Macintosh program. The results are as follows: 1. Water solubility value of calcium hydroxide-eugenol compound (20.98${\pm}$2.94%) was statistically higher than those of Tubli-seal$^{(R)}$(2.52${\pm}$0.49%)(p<0.05). 2. Water sorption value of calcium hydroxide-eugenol compound (59.72${\pm}$17.75%) was statistically higher than those of Tubli-seal$^{(R)}$(3.15${\pm}$0.76%)(p<0.05). 3. Film thickness value of calcium hydroxide-eugenol compound (0.36${\pm}$0.03mm) was statistically higher than those of Tubli-seal$^{(R)}$(0.12${\pm}$0.1mm)(p<0.05). 4. Dye penetration value after 3 days-immersion of calcium hydroxide-eugenol compound(57.63${\pm}$25.85%) was statistically higher than those of Tubli-seal$^{(R)}$(28.05${\pm}$23.46%)(p<0.05).

  • PDF

Case study of Music & Imagery for Woman with Depression (우울한 내담자를 위한 MI(Music & Imagery) 치료사례)

  • Song, In Ryeong
    • Journal of Music and Human Behavior
    • /
    • v.5 no.1
    • /
    • pp.67-90
    • /
    • 2008
  • This case used MI techniques that give an imagery experience to depressed client's mental resource, and that makes in to verbalism. Also those images are supportive level therapy examples that apply to positive variation. MI is simple word of 'Music and Imagery' with one of psychology cure called GIM(Guided Imagery and Music). It makes client can through to the inner world and search, confront, discern and solve with suitable music. Supportive Level MI is only used from safety level music. Introduction of private session can associate specification feeling, subject, word or image. And those images are guide to positive experience. The First session step of MI program is a prelude that makes concrete goal like first interview. The Second step is a transition that can concretely express about client's story. The third step is induction and music listening. And it helps to associate imagery more easily by used tension relaxation. Also it can search and associate about various imagery from the music. The last step is process that process drawing imagery, talking about personal imagery experience in common with therapist that bring the power by expansion the positive experience. Client A case targets rapport forming(empathy, understanding and support), searching positive recourse(child hood, family), client's emotion and positive support. Music must be used simple tone, repetition melody, steady rhythm and organized by harmony music of what therapist and client's preference. The client used defense mechanism and couldn't control emotion by depression in 1 & 2 sessions. But the result was client A could experience about support and understanding after 3 sessions. After session 4 the client had stable, changed to positive emotion from the negative emotion and found her spontaneous. Therefore, at the session 6, the client recognized that she will have step of positive time at the future. About client B, she established rapport forming(empathy, understanding and support) and searching issues and positive recognition(child hood, family), expression and insight(present, future). The music was comfortable, organizational at the session 1 & 2, but after session 3, its development was getting bigger and the main melody changed variation with high and low of tune. Also it used the classic and romantic music. The client avoids bad personal relations to religious relationship. But at the session 1 & 2, client had supportive experience and empathy because of her favorite, supportive music. After session 3, client B recognized and face to face the present issue. But she had avoidance and face to face of ambivalence. The client B had a experience about emotion change according depression and face to face client's issues After session 4. At the session 5 & 6, client tried to have will power of healthy life and fairly attitude, train mental power and solution attitude in the future. On this wise, MI program had actuality and clients' issues solution more than GIM program. MI can solute the issue by client's based issue without approach to unconsciousness like GIM. Especially it can use variety music and listening time is shorter than GIM and structuralize. Also can express client's emotion very well. So it can use corrective and complement MI program to children, adolescent and adult.

  • PDF